Opór tłumiący [MW] |
R1= 1.40 |
R2= 0.92 |
R3= 0.40 |
R4= 0.25 |
R5= 0.129 |
R6= 0.087 |
R7= 0.040 |
R8= 0.018 |
R9= 0.013 |
R10= 0.0041 |
R11= 2.8 kW |
R12= 0.98 kW |
Ilość okresów n |
10 |
10 |
10 |
10 |
10 |
10 |
5 |
3 |
2 |
0 |
0 |
0 |
1 tn 2 [s] 3 |
14.4 14.3 14.3 |
14.3 14.3 14.2 |
14.2 14.3 14.3 |
14.2 14.3 14.3 |
14.0 14.3 14.3 |
14.3 14.3 14.3 |
7.1 7.2 7.2 |
4.4 4.5 4.4 |
3.1 3.1 3.1 |
1.6 1.6 1.6 |
2.9 2.9 2.9 |
6.8 7.1 6.9 |
tn średnie [s] |
14.33 |
14.27 |
14.27 |
14.27 |
14.2 |
14.3 |
7.17 |
4.43 |
3.1 |
1.6 |
2.9 |
6.93 |
T [s] |
1.433 |
1.427 |
1.427 |
1.427 |
1.420 |
1.430 |
1.434 |
1.477 |
1.550 |
-------- |
------ |
------ |
A1 [dz] |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
A2 1 [dz] 2 3 |
186 185 185 |
182 182 181 |
178 177 176 |
166 165 167 |
152 153 152 |
138 134 136 |
96 96 97 |
42 43 43 |
12 13 13 |
--------- |
------ |
------ |
A2-śred [dz] |
185.5 |
182 |
177 |
166 |
152.5 |
136 |
96.5 |
42.5 |
12.5 |
------- |
------ |
------ |
d |
0.075 |
0.094 |
0.122 |
0.186 |
0.271 |
0.386 |
0.729 |
1.549 |
2.773 |
------- |
------ |
------ |
b |
0.052 |
0.066 |
0.085 |
0.130 |
0.191 |
0.270 |
0.508 |
1.049 |
1.789 |
------- |
------ |
------ |