Distribute to: EDIS
201502_011
Page 1 of 1
ESI 2.0
After installation of 2015/1, the ESI 2.0 no longer starts via the desktop link / Start menu
Affected:
ESI 2.0 Version 2015/1.
Error:
After installation of ESI 2.0 Version 2015/1, the ESI 2.0 no longer starts via the existing desktop link
and also not from the Start menu.
Remedy:
Download and install the online update "Systemsoft 9.0.1460 -> 9.0.1461" via DDM.
i The online update is also available for off-line customers (as a single-click-exe-install):
http://upm.bosch.com/SD/2015-1-SP1.exe
(
or on EDIS at \EDIS\SOFTWARE\Updates\ESI 2.0\2015-1-SP1.exe).
Alternative remedy without online access:
1. Manually start ESI 2.0 from Windows Explorer (
+ E) in the "ESItronic" folder by double-clicking "esirt.exe".
i The ESItronic folder is located at different locations, depending on the operating system and language or the
target directory that was selected when installing ESI 2.0.
Examples for Windows7 - 32-bit:
C:\Programme\Bosch\ESItronic 2.0\ESItronic\esirt.exe
C:\Program Files\Bosch\ESItronic 2.0\ESItronic\esirt.exe
Examples for Windows7 - 64-bit:
C:\Programme(x86)\Bosch\ESItronic 2.0\ESItronic\esirt.exe
C:\Program Files (x86)\Bosch\ESItronic 2.0\ESItronic\esirt.exe
ESI 2.0 is started.
2. Exit
ESI
2.0.
ESI 2.0 can now be started from the existing desktop link and from the Start menu again.