12 MV power factor correction

background image

serenity

Electrical distribution

3 to 12 kV
motor power factor correction

Reduce your costs

in complete

The comprehensive
solution for reducing
your reactive power
consumption.

serenity

Get more with the world’s Power & Control specialist

<< Back

background image

Schneider Electric
Industries SA

As standards, specifications and designs develop from time
to time, always ask for confirmation of the information given
in this publication.

Production and design: Graphème
Pictures: Rectiphase
Printing: Imprimerie des Deux-Ponts - 1000 copies

Rectiphase
BP 10 - 74371 Pringy Cedex
France
Tel.: +33 (0)4 50 66 95 00
Fax: +33 (0)4 50 27 24 19

http://www.schneider-electric.fr

CFIED001091EN ©

2001 Schneider Electr

ic - All r

ights reser

v

e

d

ART.29815

08/2001

80

1680

1180

1870

936

905

1180

Removable
cable gland
plate

1204

Rated

Rated voltage (50 or 60 Hz)

power (kvar)

3 to 4.16 kV

5 to 6.6 kV

10 to 12 kV

50
75
100
150
200
250

1 capacitor

300
350
400
450

500
550
600
650
700

2 capacitors

750
800
850
900

b

Dimensions and weight

v

external dimensions:

height: 1680 mm, width: 905 mm, depth: 1180 mm,

v

approximate weight: 425 to 530 kg.

This document has been
printed on ecological paper

Presentation

The motor correction bank is available in indoor and outdoor versions.
The indoor version is produced with an enclosure of painted steel IP23
with removable panels containing:

b

1 or 2 three-phase capacitor units delta connected;

b

3 damping reactors;

b

3 HRC fuses;

b

optionally: fuse blown indication, 2 rapid discharge reactors,

1 access door with keylock.
The outdoor version consists of an enclosure made of aluminium IP23
with removable panels, with ventilation inlets and containing:

b

1 or 2 three-phase capacitor units delta connected;

b

3 damping reactors;

b

3 HRC fuses;

b

optionally: fuse blown indication, 2 rapid discharge reactors,

1 access door with keylock, double roof.

Performance

b

use of Propivar capacitors, whose thermal withstand, low temperature

rise and overvoltage and overcurrent withstand ensures an excellent
service life;

b

use of HRC fuses preventing shutdown of the motor to be corrected

in event of a fault on the capacitor bank;

b

covered enclosure contributing to personnel safety;

b

simplicity of installation and connection of the power cables;

b

compact equipment of reduced size;

b

options available according to installation requirements and upgrading,

(rapid discharge reactors, fuse blown indicator).

Data

b

insulation voltages: 7.2 and 12 kV;


Document Outline


Wyszukiwarka

Podobne podstrony:
Digital Control Of Switching Power Supply Power Factor Correction Stage
[ebook renewable energy] Home Power Magazine 'Correct Solar Panel Tilt Angle to Sun'
[ebook renewable energy] Home Power Magazine 'Correct Solar Panel Tilt Angle to Sun'
THREE PHASE 200 KVA UPS WITH IGBT CONSISTING OF HIGH POWER FACTOR CONVERTER AND INSTANTANEOUS WAVEFO
12 Leasing, Factoringid 13519 ppt
12 Put the verb into the correct form
THE POWER OF SIX Pittacus Lore tłum nieof rozdz 12 15
L J Smith Dark Visions1 Strange Power [s1 12]
12 Steps to Power Presence How to Exert John Baldoni
(Ebook) Radio & Electronics Course 81 Power Supply 12 Volt 3 Amp
wykład 12 pamięć
Figures for chapter 12
Mechanika techniczna(12)
Socjologia wyklad 12 Organizacja i zarzadzanie

więcej podobnych podstron