APM120
CONTENTS
PAGE
APPLICATIONS
1.1
SPECIAL FUNCTIONS
3.1
CONNECTOR LOCATIONS
2.1
Version 1.0 08/03
APPLICATIONS MANUAL
FIAT/ALFA/LANCIA IMMOBILISER SYSTEM
ALFA
FIAT
1.1
APPLICATIONS
VEHICLE YEAR
SYS KEY
PROG
PLIP
PROG
KEY
INFO
LIVE
DATA
FAULT
CODES
CABLE
147 ALL
CAN
Y
Y
Y
Y
ADC110-B
156 98MY
ON
ISO
Y
Y
Y
Y Y
ADC110-B
166 98MY
ON
ISO
Y
Y
Y
Y Y
ADC110-B
VEHICLE YEAR
SYS KEY
PROG
PLIP
PROG
PLIP
INFO
LIVE
DATA
FAULT
CODES
CABLE
SCUDO ALL
ISO Y Y
Y
Y ADC110-B
DOBLO ALL
ISO Y Y Y
Y ADC110-B
DUCATO 98MY
ON
ISO
Y
Y
Y
Y ADC110-B
MULTIPLA 98MY ON ISO
Y
Y
Y
Y
ADC110-B
PALIO ALL ISO Y Y Y
Y ADC110-B
PUNTO NEW CAN Y Y Y
Y ADC110-B
SEICENTO 99MY ON ISO
Y
Y
Y
Y
ADC110-B
STILO ALL CAN Y Y Y
Y ADC110-B
ULYSSE ALL
ISO Y
Y
Y
Y ADC110-B
1.2
APPLICATIONS
LANCIA
VEHICLE YEAR
SYS
KEY
PROG
PLIP
PROG
ACTUA-
TORS
FAULT
CODES
CABLE
LYBRA ALL ISO
Y
Y
Y ADC110-B
PHEDERA ALL ISO
Y
Y
Y
ADC110-B
THESIS 98MY
CAN
Y
Y
Y
Y
ADC110-B
Z ALL
ISO Y
Y Y
ADC110-B
2.1
CONNECTOR LOCATIONS
GTV
147
ALFA
2.2
CONNECTOR LOCATIONS
PUNTO
SCUDO
FIAT
2.3
CONNECTOR LOCATIONS
SEICENTO
STILO
FIAT
2.4
CONNECTOR LOCATIONS
GTV
FIAT
3.1
SPECIAL FUNCTIONS
CAN SYSTEMS
:
From the main diagnostic menu select
SPECIAL FUNCTIONS.
Select PROGRAM KEYS from the special
functions menu.
NOTE : ANY KEYS NOT
PROGRAMMED AT THIS POINT WILL
BE DELETED PERMANENTLY. EVEN
EXISTING KEYS !
To enter the 5 digit security code use the
numerical keypad keys.
ECU
IDENTIFICATION
FAULT
CODES
SPECIAL
FUNCTIONS
DIAGNOSTIC MENU
PROGRAM KEYS
KEY
INFORMATION
REMOTE
INFORMATION
ACTUATORS
SPECIAL FUNCTIONS
PRESS ENTER KEY
SECURITY CODE
_ _ _ _ _
KEYS NOT AVAILABLE WILL
BE DELETED!
PROGRAMMING KEYS
PRESS ENTER KEY
3.2
SPECIAL FUNCTIONS
The number of existing keys pro-
grammed is displayed.
To exit press the BACK key on the
AD100. Otherwise press ENTER to
continue.
REMOVE KEY from ignition then IN-
SERT next key.
Switch IGNITION ON.
Press ENTER to continue.
The number of keys now programmed
in is displayed.
To continue and program in RE-
MOTES press ENTER. Otherwise
press BACK to exit.
KEYS PROGRAMMED: 1
BACK TO EXIT
ENTER TO PROGRAMME
NEXT KEY
PROGRAMMING KEYS
REMOVE KEY
INSERT NEXT KEY
SWITCH IGNITION ON
PROGRAMMING KEYS
PRESS ENTER KEY
XX KEYS PROGRAMMED
BACK TO EXIT
ENTER TO PROGRAM
REMOTES
PROGRAMMING KEYS
3.3
SPECIAL FUNCTIONS
CAN SYSTEMS
To program in remotes follow the on
screen instructions from the PROGRAM-
MING KEYS screen.
The programming remotes screen is dis-
played. It indicates the number of remotes
stored.
To program in another remote press EN-
TER otherwise press BACK to exit.
The number of remotes stored has in-
creased.
When exiting, this screen is shown indi-
cating the total number of remotes pro-
grammed in.
PRESS REMOTE
REMOTES STORED : 00
BACK TO EXIT
ENTER TO PROGRAM
NEXT REMOTE
PROGRAMMING REMOTES
REMOTES STORED : 2
PROGRAMMING REMOTES
PRESS ENTER KEY
PRESS REMOTE
REMOTES STORED : 01
BACK TO EXIT
ENTER TO PROGRAM
NEXT REMOTE
PROGRAMMING REMOTES
3.4
SPECIAL FUNCTIONS
CAN SYSTEMS
To view Key information follow the menu
selection procedure
Diagnostics menu>Special functions>
Key Information
To view Key information follow the menu
selection procedure
Diagnostics menu>Special functions>
Remote Information
KEYS STORED:
2
LOST KEYS:
1
LOST KEY ID:
1232
IGNITION: ON/OFF
KEY INFORMATION
BACK TO EXIT
REMOTES STORED:
2
LOST REMOTES:
1
LOST REMOTE ID: 123456
REMOTE DR LOCK: ON
REMOTE DR UNLOCK: ON
REMOTE BT UNLOCK: OFF
REMOTE INFORMATION
BACK TO EXIT
3.5
SPECIAL FUNCTIONS
ISO SYSTEMS
From the main diagnostic menu se-
lect SPECIAL FUNCTIONS.
Select PROGRAM KEYS from the spe-
cial functions menu.
To enter the 5 digit security code use
the following procedure :-
Press to elect Number & Letter
Press To Erase the previous selec-
tion
Press To ENTER selection.
Press To Finish PIN selection.
ECU
IDENTIFICATION
FAULT
CODES
SPECIAL
FUNCTIONS
DIAGNOSTIC MENU
PROGRAM KEYS
LIVE
DATA
ACTUATORS
KEY
INFORMATION
SPECIAL FUNCTIONS
PRESS ENTER KEY
SECURITY CODE
_ _ _ _ _
SECURITY CODE
1 2 3 4 5
IS THIS CORRECT
OK = ENTER CLEAR =BACK
3.6
SPECIAL FUNCTIONS
OR
NOTE : ANY KEYS NOT
PROGRAMMED AT THIS POINT
WILL BE DELETED PERMA-
NENTLY. EVEN EXISTING KEYS !
Depending on the status of the key in-
serted the following messages will ap-
pear:
Press ENTER to continue.
Press BACK to EXIT otherwise ENTER
to continue.
KEYS NOT AVAILABLE WILL
BE DELETED!
PROGRAMMING KEYS
PRESS ENTER KEY
KEY ERROR
PROGRAMMING KEYS
PRESS ENTER KEY
KEYS PROGRAMMED: 1
BACK TO EXIT
ENTER TO PROGRAM
NEXT KEY
PROGRAMMING KEYS
3.7
SPECIAL FUNCTIONS
If ENTER is pressed on wither of the
previous screens then this screen will be
displayed indicating the key program-
ming procedure.
To enter the 5 digit security code use
the following procedure :-
Press to elect Number & Letter
Press To Erase the previous selec-
tion
Press To ENTER selection.
Press To Finish PIN selection.
REMOVE KEY
INSERT NEXT KEY
LEAVING IN STOP POSITION
PROGRAMMING KEYS
PRESS ENTER KEY
SECURITY CODE
_ _ _ _ _
SECURITY CODE
1 2 3 4 5
IS THIS CORRECT
OK = ENTER CLEAR =BACK
3.8
SPECIAL FUNCTIONS
The key information screen is displayed.
Press ENTER to continue.
KEYS PROGRAMMED: 2
KEY 1:
12345678
KEY 2:
12345678
KEY 3: 12345678
KEY 4:
12345678
KEY INFORMATION
PRESS ENTER KEY