123. FREYSSINET C AND K SYSTEMS ANCHORAGES

C System
123.16 Bonded-Internal Prestressing

C I’ C

OUPLERS

PPC

123/

16-

02.95

SYSTÈME C

COUPLEUR C I’

Ø P

sheath
Ø

int.

D

x 1

x 2

x 3

leak proof joint

N

M

C SYSTEM

C I’ COUPLERS

UNIT

D

M

N

P

X1

X2

X3

C I’ 3 C 15

40

1050

1000

102

250

500

750

C I’ 4 C 15

45

1050

1000

127

250

500

750

C I’ 7 C 15

60

1050

1000

127

250

500

750

C I’ 13 C 15

80

1200

1150

203

300

550

800

C I’ 19 C 15

95

1200

1150

219

300

550

800

C I’ 25 C 15

110

1250

1200

273

350

600

850

C I’ 31 C 15

120

1350

1300

273

400

650

900

3C15

4C15

7C15

13C15

19C15

25C15

31C15

background image

PAGE 2/2

123. FREYSSINET C AND K SYSTEMS ANCHORAGES

PPC

123/

16-

02.95

Monostrand prolongator for C I’ and R
(machined)

Monostrand prolongator for C I’ and R
(moulded)

189

189

spring

plug

jaws

body

bearing ring

adapter

Ø 44

spring

jaws

Ø 52

30

spring bearing ring

monoblock body


Wyszukiwarka

Podobne podstrony:
123 19 System K lacznik C'id 13934
123 15 System C lacznik C'id 13930
123 20 System K lacznik C I'id 13935
123 19 System K lacznik C'id 13934
123 21 System K lacznik R
123 17 System C lacznik R
cw 16 odpowiedzi do pytan id 1 Nieznany
Kanicki Systemy Rozdzial 10 id Nieznany
Cwiczenie nr 16 Modele przestrzenne (3D) id 998
IS wyklad 03 16 10 08 MDW id 22 Nieznany
o systemie oceny zgodnosci id 3 Nieznany
Glowny system pamieciowy GSP id Nieznany
16.Systemy KD, Pedagogika, Andragogika
123 22 System C i K Zakotwienie bierne NE'

więcej podobnych podstron