SmartWire-DT
The innovative communication system for
switchgear
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
2
2010 Eaton Corporation. All rights reserved.
SmartWire Pro
SmartWire-DT Technology – the easy way to connect
History
Direct control wiring PLC
– switching devices
Past
Remote I/O
Length of wired cables is
reduced, but problem
mainly unchanged
Up to now
Control wiring is
completely obsolete.
Control information is
directly transmitted
between PLC and control
devices
SmartWire- Darwin
Summa
ry:
SWD-Tec
hnology a
llows for
the frst t
ime cost
attractiv
e
network i
nterface
s for
“simple”
switchin
g /
comman
d device
s
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
3
2010 Eaton Corporation. All rights reserved.
Contactors or command and control
devices had to be wired in a time-
consuming way.
Control wiring of components now
becomes obsolete. SmartWire-
Darwin communication interfaces
replace the control wiring and
additional required PLC I/Os.
Basic component of the SmartWire-
Darwin communication system is a
special designed ASIC, which
contains all communication and
device specifc functions on a
minimal footprint.
SmartWire-DT– the easy way to connect
Motivation
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
4
2010 Eaton Corporation. All rights reserved.
SWD technology offers
cost attractive
communication solution
for simple devices.
SmartWire-DT– the easy way to connect
Typical products:
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
5
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Basic architecture
feld bus
SWD
99 stations, 600m, 1024 Byte cyclic process
data
SWD
PLC
RMQ PKZ DIL PKE I/O RMQ extern DS7
NZM
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
6
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Overview
Gateway
Flat cable
Contactor /
Motor protection
circuit
Powerfeed
I/O Modul
Flat cable coupling
RMQ
Front
Enclosure feed through plug
RMQ Base
Terminating resistor
Enclosure feed
through plug
Round cable
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
7
2010 Eaton Corporation. All rights reserved.
• Standard switching components get a communication
interface
• Reduction of control wiring and PLC I/O
• Can be used inside and outside the cabinet
• Standard Moeller components are used
• Power supply of the contactors included in SWD cable
• Interface to PLC via feld bus (DP, CAN)
• Up to 99 participants for each gateway
• Length up to 600m
• All interfaces with connectors
SmartWire-DT– the easy way to connect
Summary
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
8
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Product overview
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
9
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
SmartWire-Darwin-Gateways
• Profbus DP-Slave
• Up to 58 SWD-participants
• Automatic baud rate detection up to
12MB
• Separate 24V Supply for
• Gateway and ~ 30 SWD-modules
• Contactors (24VDC 3A)
• Address setting via DIP-Switch
• CANopen Slave
• Up to 99 SWD-participants
• Automatic baud rate detection up to
1MB
•Separate 24V Supply for
• Gateway and ~ 30 SWD-modules
• Contactors (24VDC 3A)
• Address setting via DIP-Switch
• Bus Termination via DIP-Switch
EU5C-SWD-DP
EU5C-SWD-CAN
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
10
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
RMQ – function elements front fxing
Function elements:
• 1 changeover
• 2 changeover
• LED R,G,B,W
• 1 changeover with LED R,G,B,W
• 2 changeover with LED R,G,B,W
• Control and signaling devices remain
unchanged.
• M22-SWD function-elements are used
instead of contact or LED-elements.
• Combinations of (multiple) contact
elements and LED-elements are replaced by
a single powerful function element.
• Control wiring becomes obsolete.
Connection to the SmartWire-Darwin cable is
realized with SWD device plug.
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
11
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
RMQ – function elements base fxing
• Control and signaling devices and existing
M22-I enclosures remain unchanged.
• M22-SWD function-elements are used
instead of contact or LED-elements.
• Combinations of (multiple) contact
elements and LED-elements are replaced by
a single powerful function element.
• PCB M22-SWD-I* is used to adapt function
elements to SWD
• Flexible Interface to the SWD-round cable
(direct, plug)
• Integrated network termination
Function elements:
• 1 changeover
• 2 changeover
• LED R,G,B,W
• 1 changeover with LED R,G,B,W
• 2 changeover with LED R,G,B,W
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
12
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
DIL- Element
• Standard Motor protection circuit are
used
• SmartWire-Darwin function elements
are connected on contactors (DILA,
DILM7–DILM38, max. 18KW)
• The interface to the SWD network is
realized with SWD-device connector.
• Features
• Drive contactor
• Feedback connector
• Two additional Inputs (e.g. Trip,
short circuit, additional auxiliary
contact)
• Also available with additional
Manual-Auto Switch for direct
operation
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
13
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Function element for PKE12/ 32
• Function element for networkable motor starter
combination MSC-DE
A
-… or trip block PKE-XTU
A
• Suitable for contactors DILM7 – DILM32
• Connection to the SmartWire-Darwin cable is
realized with SWD device plug.
•Available functions on SWD
• Controlling contactor
• Status information contactor / PKE
• Motor current of the highest phase [%]
• Thermal motor model [%],
• Trip reasons
• Settings: Ir, CLASS, trip block type, status
M/A- Switch
• Overload relay function ZMR (contactor
disconnects main phases in case of overload)
•Manual/ Auto- functionality (like DIL-SWD-32-002)
PKE-SWD-32
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
14
2010 Eaton Corporation. All rights reserved.
• Cyclic data with different data profles
• Profle 1: 2 Byte
(switching status, set value Ir, trip reasons)
• Profle 2: 4 Byte
(Profle 1 + motor current, thermal motor
model)
• Profle 3: 5Byte
(Profle 2 + trip block type, set value time
delay)
• Acyclic data objects
• motor current
• thermal motor model
• trip block type + set value time delay
!
Precondition:
-DP/CAN Gateway- Firmware- Version >=1.10
- EDS/GSD Files >=1.10
-SWD-Assist >=1.10
PKE-SWD-32
SmartWire-DT– the easy way to connect
Function element for PKE12/ 32
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
15
2010 Eaton Corporation. All rights reserved.
XSWD-704
SmartWire-DT– the easy way to connect
Function element for NZM1,2,3
• Standard Moeller NZM 1,2,3 circuit breaker
are used
• SmartWire-Darwin function element XSWD-
704 is connected
• Available functions on SWD
• Status, Trip reasons
• Overload warnings
• Settings
• NZM identifcation
• Actual currents
• 2 Outputs for driving Remote Control
Unit
• Energy measurement with additional
XMC-S0 unit
• S0-Energy Counter Value
XMC-S0
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
16
2010 Eaton Corporation. All rights reserved.
XSWD-704
SmartWire-DT– the easy way to connect
Function element for NZM1,2,3
XMC-S0
Data Profile
1
3 Byte
2
11 Byte
3
15 Byte
4
31
Byte
SWD Status
NZM Status
X
X
X
X
Currents
X
X
X
Energy Counter
Value
X
X
NZM
Configuration,
Settings
X
NZM Breaker data
(type, function,
version)
X
Several data profles are provided for optimized
communication to PLC
If data profle 1-3 is selected, missing data can be
read using standard acyclic data communication
functions.
!
Precondition:
- DP/CAN Gateway- Firmware- Version >=1.10
- EDS/GSD Files >=1.10
- SWD-Assist >=1.20
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
17
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Digital Input / Output modules
• I/O modules to connect digital devices
without integrated SWD-interface
• EU5E-SWD-8DX 8 inputs
• EU5E-SWD-4DX 4 inputs 3-wire with 24V
Supply
• EU5E-SWD-4D4D 4 inputs, 4 outputs 24V
0,5A
• EU5E-SWD-4D2R 4 inputs, 2 relay, 3A
• EU5E-SWD-X8D 8 outputs 24V 0,5A
• Mounting next to the desired place in the
cabinet
• Remaining control wiring is further more
reduced
• Direct control of contactors up to 37KW
(DILM40-72) without auxiliary contactors
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
18
2010 Eaton Corporation. All rights reserved.
SmartWire-DT – the easy way to connect
Analog Input / Output modules
• SWD-modules for interface of analog sensors
and actors
• EU5E-SWD-4AX 4 analog inputs 0-10V/0-20mA
• U/I selectable for each input
• 12 bit resolution
• EU5E-SWD-2A2A 2 analog inputs 0-10V/0-20mA
2analog outputs 0-10V/0-20mA
• U/I selectable for each
input/output
• 12 bit resolution
• EU5E-SWD-4PT 4 temperature inputs
• PT100,1000,NI1000
• U/I selectable for each
input/output
• 2/3 wire
• Temperature range
-50 .. +200°C (PT)
-50 ..+150°C (Ni)
• Representation 1/10°C,F,binary
value
• Overrun / Underrun diagnostic
Analog I
12 bit
0 – 10 V,0-20mA
Analog Q
12 bit
0 – 10 V,0-20mA
Temperature
–50..+150(200)°C
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
19
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Accessories
Housing bushing socket
Coupling
Crimping
tools
Switch cabinet bushings
(Transition flat-round cable)
Power Feed
Module
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
20
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Mounting
Place device plug on flat cable
Shift device plug to fnal position
Fix device plug with pliers
Assemble device plug on SWD- element
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
21
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
PLC interface
Addressing of SWD-elements is done
automatically
Press confguration button
1 2 3 4 5 6 7 ….
Connect gateway with PLC
Start PLC
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
22
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
SWD-Assist simplifes planning of SmartWire-Darwin-Networks
Graphical planning tool for SWD-networks
Stores project specifc
GSD fle for direct use in
PROFIBUS confguration tool
Calculation of power
consumption and proposal for
insertion of additional Power Feed
module
- Contactors (24 V, 3A)
- Network supply (15 V, 0,7A)
Printout of SWD Participants
with ordering information
Syntax check
Auto complete function
adds missing SWD
components
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
23
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
SWD-Assist: Online test and commissioning
Online access via gateway
diagnostic interface (V1.10)
Upload target confguration
Compare target confguration
Display confguration differences
Display of process values
Display of device settings
Display of diagnostic information
Update Gateway-Firmware
Verify SWD-Network without PLC
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
24
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
PLC confguration
fel
d
bus
SWD
PLC
SWD Confguration can be compared
to confguration of standard remote
I/O
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
25
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
SWD
Confguration in STEP 7
Confguration of SWD-
Network is similar to the
confguration of a modular
DP Slave. Features are
defned via GSD-fle.
A single SWD-module is
equal a single I/O- module of
such a remote I/O
system( e.g. ET200)
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
26
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
SWD
Confguration in CoDeSys
Confguration of SWD-
Network is similar to the
confguration of a modular
DP Slave. Features are
defned via GSD-fle.
A single SWD-module is
equal a single I/O- module of
such a remote I/O
system( e.g. XION)
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
27
2010 Eaton Corporation. All rights reserved.
SmartWire-DT– the easy way to connect
Benefts of SmartWire-Darwin Technology?
Darwin Technology offers security and simplifcation
Time saving (Less interfaces, components)
Reduction of wiring, I/O Modules (PLC), auxiliary contacts
Project:
Cost reduction (Less cables, components, space)
Less components to consider (Example: one RMQ-function element replaces
command and signalization component
Simplifcation of assembly
Assembly
Time saving due to elimination of control wiring
Elimination of wiring test
Less components to order / unpack
Order / Delivery
Service
More diagnostics
Simple replacement. All SWD-participants with
connector
Sum
mar
y:
Les
s ti
me
Red
uce
d sp
ace
Les
s co
st
Mor
e se
cur
ity
Mor
e po
ssib
iliti
es
Refer to protection notice ISO 16016
07. Nov. 2008
Refer to protection notice ISO 16016
07. Nov. 2008
28
2010 Eaton Corporation. All rights reserved.