sprzet lab mikromanometry

background image

Sprzęt

Mikromanometry

background image

Alnor 632-530-110 Portable Micromanometer

background image

AXD 560 Digital

Manometer

Pressure Range -5 to 15" H2O (-1245 to 3735 Pa)

Velocity Range

250 to 15,500 ft/min (1.27 to 78.7 m/s)

Volume Range

up to 9,999,000 ft3/m, m3/h, l/s

Resolution

0.005" H2O (0.1 Pa)

Accuracy

Pressure: ±1% of reading ±0.005"WC

Pressure: ±1% of reading ±1 Pa

Velocity: ±1.5% of reading at 2000 ft/min (10.16 m/s)

Volume: Depends on Velocity

background image

2000P Series Digital Manometers

Model

Operating Range

User selectable units

Overrange Protection

2020P

25.00 mbar

2500 Pa

10.05 inches of water

255.3 mm of water

0.73 inches of mercury

18.75 mm mercury

0.36 PSI

350 mBar (140"WC)

2021P

130.0 mBar

13.00 kPa

52.28 inches of water

1320 mm of water

3.83 inches of mercury

97.5 mm of water

1.88 PSI

750 mBar (300"WC)

2022P

1999 mBar

199.9 kPa

804 inches of water

20.43 metres of water

59.00 inches of mercury

150.0 cm of mercury

29.00 PSI

4 Bar (60 PSI)

2023P

7.00 Bar

700 kPa

2815 inches of water

71.5 metres of water

206.7 inches of mercury

5.25 metres of mercury

101.5 PSI

10 Bar (150 PSI)

2026P

10.00 Bar

1000 kPa

4022 inches of water

102.2 metres of water

295.3 inches of mercury

5.25 metres of mercury

145 PSI

10 Bar (150 PSI)

background image

Series 477 Digital Manometer

Accuracy

±0.5% of full scale from 60 to 78°F (15 to 25°C);

±1% of full scale from 32 to 60, 78 to 104°F (0 to 15, 25 to

40°C)

Storage Temperature

4 to 176°F (-20 to 80°C)

Pressure Hysteresis

0.1% of full scale

background image

Mikromanometry DM2/DM2L

Parametr

DM2L

DM2

Zakres ciśnienia

-99,99...0...+ 99,99 mbar

-10,0...0...+ 10,0 kPa

-1,450...0...+ 1,450 psiI

-2000...0...+ 2000 mbar

-200,0...0...+200,0 kPa

-30.00...0...+30,00 psi

Rozdzielczość (ustawialna)

0,1 lub 0,01 mbar

0,1 lub 0,001 kPa

1 lub 0,1 mbar

0,1 lub 0,01 kPa

Dokładność w 20°C

1013mbar

±2% wartości mierzonej (-300...300mbar)

±0.5% zakresu (<-300mbar, >300mbar)

Temperatura pracy

0 - 40°C

0 - 40°C

background image

Mikromanometr EMA150

Zakresy pomiarowe

0...200Pa,

0...2kPa

0...20kPa,

0...200kPa

Dopuszczalne przeciążenie

20 x zakres (zakresy 200Pa i 2kPa)
10 x zakres (zakres 20kPa)

1.2 x zakres (zakres 200kPa)

Dokładność

±1% zakresu ±1 cyfra

Histereza

0.1%

background image

Mikromanometr EMA160

Zakresy pomiarowe

0...200Pa / 0(1.5)...18m/s

0...2kPa / 0(5)...58m/s
0...20kPa / 0(15)...180m/s

Sposób obliczania prędkości

v=1.291 x (

p)

1/2

Dopuszczalne przeciążenie

20 x zakres (zakresy 200 i 2kPa)
10 x zakres (zakres 20kPa)

Liniowość

±1% zakresu ±1 cyfra

Dokładność pomiaru prędkości

±2.5%

Histereza

<0.1%

background image

Mikromanometr EMA84

Zakresy pomiarowe

0...100Pa,

0...1kPa,

0...10kPa,

0...100kPa

Zakres wskazań

0...199% zakresu nominalnego

Dopuszczalne przeciążenie

10 x zakres (zakresy do 10kPa)

2 x zakres (zakres 100kPa)

Dokładność

±1% zakresu ±1 cyfra

±0.5% zakresu ±1 cyfra (opcja)

±0.2% zakresu ±1 cyfra (opcja)

Histereza

0.1%

background image

Mikromanometr PVM100

Parametr

Jednostki metryczne

Zakres pomiarowy prędkości

0 do 76m/s

Zakres pomiarowy ciśnienia

±3500Pa

Rozdzielczość

1Pa

Dokładność przy 20°C

±1% wartości odczytanej ±1 cyfra

Dopuszczalne przeciążenie

17.5 kPa

Temperatura pracy

-5°C do +50°C

background image

Mikromanometr REG21

Zakresy pomiarowe

0...50, 100, 250, 500Pa,

1, 2.5, 5, 10, 20, 50, 100kPa

dostępne także inne zakresy i jednostki

Dopuszczalne przeciążenie

200 x zakres (zakresy <2.5kPa)
600kPa (zakresy

2.5kPa)

Liniowość

±1% (standard),
±0.5% (opcja dla zakresów

250Pa)

Histereza

<0.1%

Stała czasowa

20ms (opcja: 1, 2 lub 5s)

Dryft termiczny

0.04% /K (w zakresie +10...+50°C)

background image

Mikromanometry cieczowe

Mikromanometr z

rurką pochyłą typu

504

Mikromanome

try typu FL.

Zakres pomiarowy

Działka

elementarna

Typ

Pa

mm H

2

O

[mm Hg]

Pa

Gęstość cieczy

przy 20°C

Długość

podzielni

[mm]

FL40

FL100

400

1k

-

-

10

10

0.784

0.784

130

130

504/125

504/250

504/500

504/750

125

250

500

750

12

25

50

75

1

2

5

10

0.784

0.784

0.784

0.784

255

255

255

255

SJ/200

SJ/300

SJ/400

SJ/600

SJ/380Hg

SJ/760Hg

2k

3k

4k

6k

50k

100k

200

300

400

600

[380]

[760]

10

10

10

10

200

200

0.784

0.784

0.784

0.784

13.56

13.56

255

385

510

764

372

745

background image

Mikromanometry MEDM

Parametr

MEDM 500

MEDM 5K

Zakres pomiarowy ciśnienia

0 - 500Pa

0 - 5000Pa

Zakres pomiarowy prędkości

0 - 28.8m/s

0 - 91m/s

Zakres pom. natężenia

0 - 999.9m

3

/s

0 - 999.9m

3

/s

Dopuszczalne ciśnienie

różnicowe

5000Pa

50kPa

Rozdzelczość

0.1Pa

1Pa

Zakres współczynnika K

1.00 do 2.99

Zakres poprawki na

temperaturę

0 do 699°C

Zakres poprawki na ciśnienie

absolutne

70 do 140kPa

Zakres pola przekroju

0,00001 do 99.9999m

2

Dokładność pomiaru

przy 50Pa < ±3.5% wartości mierzonej

przy 100Pa < ±2.5% wartości mierzonej

powyżej 150Pa < ±1% wartości mierzonej

background image

475 Mark III Digital Manometers

Accuracy

Pressure

Hysteresis

Temperature

Effect, Zero

Reading

Operating

Temperature

Range

±0.5% of full

scale, 60-78°F

(15-25°C)

±0.1% of full

scale

0.5% of full

scale, 32-122°F

(0-50°C)

32-122°F (0-

50°C)

Part Number

Range

Metric

Maximum Pressure

475-000-FM

0-1.000"WC

0-0.249 kPa

10"WC

475-00-FM

0-4.00"WC

0-0.995 kPa

5 PSI

475-0-FM

0-10.00"WC

0-2.49 kPa

5 PSI

475-1-FM

0-19.99"WC

0-4.97 kPa

11 PSIG

475-2-FM

0-40.0"WC

0-9.95 kPa

11 PSIG

475-3-FM

0-199.9"WC

0-49.7 kPa

11 PSIG

475-4-FM

0-10.00 PSID

0-0.689 bar

58 PSIG

475-5-FM

0-19.99 PSID

0-1.378 bar

58 PSIG

475-6-FM

0-30.0 PSID

0-2.07 bar

58 PSIG

475-7-FM

0-100 PSID

0-6.89 bar

150 PSIG

475-8-FM

0-150 PSID

0-10.34 bar

150 PSIG

background image

Mikromanometry

TB-PS

Zakresy pomiarowe

200Pa, 2000Pa, 7kPa, 10kPa , 20kPa

lub 70 kPa

Zakres temp. pracy

0 ... 50

o

C

Rozdzielczość

0,1Pa, 1 Pa lub 10 Pa

Dokładność

od 0,2% do 1 %

background image

Cyfrowy

mikromanometr

różnicowy CMR-10A

pomiarowy zakres różnicy ciśnień (delta p)

+/- (0 do 1500) Pa (po przekroczeniu -

autoblokada)

rozdzielczość

0,1 Pa w zakresie (0,0 do999,9)Pa;

1 Pa w zakresie (1000 do 1500)Pa

maksymalny błąd pomiaru

+/-(0,005 | delta p | do 0,5)Pa

zakres temperatury pracy

0 do 50

o

C

zakres nastawianej wartości iloczynu

gęstości gazu i liczby kształtu rurki

spiętrzającej (beta)

0,10 do 6,00 kg/m3 co 0,01 kg/m3

background image

Manometry

Manometry

8205

8215

8230

8252

82100

Zakres pomiarowy +/-[kPa]

34,47 103,42 206,84 13,79 689,48

Maksymalna różnica ciśnień[kPa]

137,89 206,84 413,69 137,89 1034,22

Rozdzielczość

0,001 0,001 0,002 0,001 0,004

Parametry wspólne dla wszystkich modeli

Błąd pomiaru w całym zakresie [%] dla 25°C

±0,3

Czas pomiaru [msec]

0,3

Zakres kompensacji temperatury

0..50°C

Liniowość i histereza

±0,2(maks.1,0)%

background image


Document Outline


Wyszukiwarka

Podobne podstrony:
sprzet lab profilografy
sprzet lab baro higrometry
sprzet lab termometry
sprzet lab inne
sprzet lab 1
sprzet lab pirometry
sprzet lab profilografy
sprzet lab baro higrometry
MIKROMETR lab
Badanie sprzętu ochronnego-lab, badanie sprzętu ochronnego, Politechnika Radomska
MIKROMETR lab
spis lab I sem 2010
III WWL DIAGN LAB CHORÓB NEREK i DRÓG MOCZ
sprzet SGRW
postępowanie ze sprzętem jednorazowym ASEPTYKA
Diagnostyka lab wod elektrolit
ZW LAB USTAWY, OCHRONA
T 1 4 Dezynfekcja rąk i sprzętu medycznego

więcej podobnych podstron