TECHNICAL DATA SHEET IG3 Horizon 08 2008[1]

background image

08/2008

- The manufacturer reserves the right to modify the device without prior notification.

IG3 “HORIZON”

TECHNICAL DATA

Working pressure

from 0,5 to 2,0 bar

Max pressure

4,5 bar

Type E3 = 2,8 ohm ± 15%

Coil resistance

Type E2 = 2,0 ohm ± 15%

Alimentation

12 V ± 15%

E3

2,8 ms ± 3%

Peak current time

E2

2,3 ms ± 3%

E3

2,8 ms ± 3%

Minimum Injection Pulse

E2

2,3 ms ± 3%

Opening = 2,5 ms ± 5%

E3

Closing = 2,0 ms ± 5%

Opening = 2,0 ms ± 5%

Complete opening / closing time

(tested at 1 bar pressure, 12V,

with total inj. Time 5 ms)

E2

Closing = 2,0 ms ± 5%

Inlet gas fitting

Rubber hose Ø10mm

Outlet gas fitting

Calibrated nozzles M8x1, external Ø7mm

Calibrated hole range (for nozzles)

1,0 - 3,5 mm (0,25mm step)

T range

-20 / + 120° C

Agreement

67R-01 / 110R-00

background image

N o z z l e

HP / CYL.

Ø

from to

1,00

… 11

1,50

12 16

2,00

17 22

2,50

23 30

3,00

31 38

3,50

39 50

Note: this is only a suggestion; use also intermediate nozzles diameter to have
correct running at idle.
Note 2: Suggested nozzles and flow graphics are based on E3 type;
for E2 type, consider +10-15% of gas mass flow.


T inj = total injection time for gas injector
T peak = max current or voltage time
T hold / PWM = maintenance time



T

hold: It's maintenance time, made by reducing current or voltage to a costant value,

less than max one (Peak).

T

PWM: It's maintenance time, made by using pulse-width modulation

Pulse-width modulation (PWM) of a signal or power source involves the modulation of its duty cycle, to either convey
information over a communications channel or control the amount of power sent to a load.
Pulse-width modulation uses a square wave whose duty cycle is modulated resulting in the variation of the average value
of the waveform.

The duty cycle (D) is defined as the ratio between the pulse duration (t) and the period (T) of a rectangular waveform.
Duty cycle is the proportion of time during which a component, device, or system is operated. Suppose a plunger operates
for 0,100 milliseconds, and is shut off for 0,070 ms, then is run for 0,030 ms again, and so on. The drive runs for 30 out of
100 microseconds, or 30/100 of the time, and its duty cycle is therefore 30/100, or D=30% (percent).

IG3 suggested driving values

Type E3

Type E2

Coil Resistance ( ± 15%)

2,8 ohm

2,0 ohm

Peak current time (MAX Tpeak)

2.8 ms

2.3 ms

Peak current (± 10%)

4 A

6 A

Max holding current (± 10%)

2 A

2 A

Suggested holding current (± 10%)

1 A

1 A

PWM 'on' current (Duty cycle ±
20%)

50% 40%

Minimum Injection Pulse

2.8 ms ± 3%

2.3 ms ± 3%


Wyszukiwarka

Podobne podstrony:
TECHNICAL DATA SHEET IG1 Apache 08 2008[1]
eismann agregaty technical data sheet
CW2006EX Mill Turn data sheet web
cx5500 data sheet enus
2008 Metody obliczeniowe 08 D 2008 11 11 21 31 58
MAXTOR DiamondMax 10, diamondmax 10 data sheet
InfoDług 08 2008
CW2006EX Turn data sheet web
Holder Block data sheet
AMD Family 10h Power and Thermal Data Sheet
European Demographic Data Sheet 2010
Exell D Sabic data sheet
F 200 Data Sheet
CADWELD Mechanical Rebar Splice data sheet
0 Technical Data
Cisco SIP Proxy Server Data Sheet
DT Vitosol 200 T SD2A (08,2008)

więcej podobnych podstron