Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ 11

Emergency stop relay and safety
gate monitor in accordance with
VDE 0113-1, 11/98, EN 60204-1,
12/97 and IEC 204-1, 11/98.

Features

● Dual-channel wiring with short

circuit detection across the
input contacts

● Monitored manual or automatic

reset can be selected

● 2 semiconductor outputs

(Fault, K1/K2)

● Each AC unit can be operated

with 24 VDC

Approvals

Technical Details

PNOZ 11

Electrical Data

Supply Voltage

AC: 24, 42, 48, 110, 115, 120, 230, 240 V

DC: 24 V

Tolerance

85 ... 110 %

Power Consumption

Approx. 4 W/7 VA

Voltage and Current at the

Input Circuits

24 VDC, 80 mA/160 mA

Reset Circuits and Feedback Control Loop 24 VDC, 50 mA

Switching Capability in accordance with

EN 60947-4-1, 10/91

AC1:

240 V/8 A/2000 VA

DC1: 24 V/8 A/200 W

EN 60947-5-1, 10/91 (DC13: 6 cycles/min.) AC15: 230 V/5 A; DC13: 24 V/7A

Output Contacts

7 safety contacts (N/O)

1 auxiliary contact (N/C)

Contact Fuse Protection

10 A quick or 6 A slow

(EN 60947-5-1, 10/91)

Semiconductor Outputs

24 VDC/20 mA, short-circuit protected

External Supply Voltage

24 VDC ±20 %

Times

Switch-on delay

Max. 500 ms

Delay-on De-energisation

Max. 50 ms

Recovery Time

Approx. 1 s

Simultaneity channel 1/2

¥

Max. Supply Interruption before De-energisation

Approx. 10 ms

Mechanical Data

Maximum Cross Section of

2 x 1.5 mm

2

or 1 x 2.5 mm

2

External Conductors

Single-core or multi-core

with crimp conenctors

Dimensions (H x W x D)

87 x 90 x 121 mm

Weight

700 g

Description

● 90 mm, P-93 housing, DIN-Rail

mounting

● Positive-guided relay outputs:

– 7 safety contacts (N/O)
– 1 auxiliary contact (N/C)

● Connections for

– E-STOP button
– safety gate limit switch
– reset button

● LEDs for power, channel 1IN,

channel 2 IN, Start (reset),
channel 1 and channel 2

● Increase in the number of

safety contacts available by
connecting expander modules.

PNOZ 11

Operating Modes

● Single-channel operation

● Dual-channel operation

● Automatic reset

● Manual reset

● Monitored manual reset

NSG-D-2-058-07/02

background image

1

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

14

K4

K5

13

Y1

Y2

K4

K5

1L1

1L2

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ 11

Internal Wiring Diagram

External Wiring

● Example 1
Single-channel E-STOP wiring with
manual reset.

● Example 2
Dual-channel E-STOP wiring with
manual reset.

● Example 3
Single-channel E-STOP wiring with
monitored manual reset.

● Example 4
Single-channel safety gate control
with manual reset.

● Increase in safety contacts
The number of output contacts can
be increased by using expander
modules or relays/contactors with
positive-guided contacts.

● Example 5
Dual-channel safety gate control with
manual reset.

● Example 6
Dual-channel safety gate control with
automatic reset.

S11 S31

S33

S12

S34

S32

S21

S22

Y1

Y2

S11 S31

S33

S12

S34

S32

S21

S22

S34

S37

Y1

Y2

S32

S34

S33

S31

S11

S22

S12

S21

Y2

Y1

– Key

S1/2:

E-STOP or safety gate switch

S3:

Reset button

Switch operated

Gate open

Gate closed

A1 A2

S37

S12

S22

S21

Y2

53 63 73

81

54 64 74

82

S32

Y1

S34

S33

S31

13

33 43

14

34 44

K1

K2

23

24

&

Y35

Y31

B

B

Y32

Y30

CH1

CH2

Start
Unit

S34

AC

DC

S11

Input

circuit

Feedback

control

loop

Reset
circuit

Input

circuit

Input circuit

U

B

Safety contacts

Auxiliary

contact

S21

S22

S12

S34

S32

S33

S11

S31

Y2

Y1

S12

S34

S33

S11

S21

S32

S22

S31

Y2

Y1

S12

S34

S33

S11

S21

S32

S22

S1

S2

S31

Y2

Y1

NSG-D-2-058-07/02

background image

1-3

1

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ 11

NSG-D-2-058-07/02

General Technical Data

Unless stated otherwise in the technical details for the specific unit

Electrical Data

Frequency Range AC

50 ... 60 Hz

Residual Ripple DC

160 %

Contact Material

AgSnO

2

Continuous Duty

100 %

Environmental Data

EMC

EN 50081-1, 01/92, EN 50082-2, 03/95

Vibration in accordance with

Frequency: 10 ... 55 Hz,

EN 60068-2-6, 04/95

Amplitude: 0.35 mm

Climatic Suitability

DIN IEC 60068-2-3, 12/86

Airgap Creepage

DIN VDE 0110 part 1, 04/97

Ambient Temperature

-10 ... +55 °C

Storage Temperature

-40 ... +85 °C

Mechanical Data

Torque Setting on Connection Terminals

0.6 Nm (screws)

Mounting Position

Any

Housing Material

Thermoplast Noryl SE 100

Protection

Mounting: IP 54

Housing: IP 40

Terminal Range: IP 20

The units were tested in accordance with the relevant standards current at
the time of development.

Order References

Type

U

B

Order No.

PNOZ 11

24 V AC/DC

774 080

PNOZ 11

42 V AC/24 V DC

774 081

PNOZ 11

48 V AC/24 V DC

774 082

PNOZ 11

110 V AC/24 V DC

774 083

PNOZ 11

115 V AC/24 V DC

774 084

PNOZ 11

120 V AC/24 V DC

774 085

PNOZ 11

230 V AC/24 V DC

774 086

PNOZ 11

240 V AC724 V DC

774 087


Wyszukiwarka

Podobne podstrony:
pnoz x3p gb B5VW75QW7OGZ3YAVF6G43JUJXVPZSFBDAWURFWI
pnoz xe1 gb[1] OHVH62VRNRX27UG45CP4SMHI65HT275IHJKNDPA
PNOZ EX GB
PNOZ XV2P GB
PNOZ X3P GB
PNOZ X2P GB
PNOZ 16SP GB
PNOZ XE2 GB
PNOZ XV2 1 GB
PNOZ XV3 GB
PNOZ E1P GB
PNOZ 2VQ GB
PNOZ XM1 GB
PNOZ X2C GB
PNOZ X3 1 GB
PNOZ 16 GB
PNOZ X13 GB

więcej podobnych podstron