background image

NA to BS EN 1993-1-9:2005

UK National Annex to 

Eurocode 3: Design of 

steel structures –

Part 1-9: Fatigue

ICS 91.010.30

NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW

NATIONAL ANNEX

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

Publishing and copyright information

The BSI copyright notice displayed in this document indicates when the 
document was last issued.

© BSI 2008

ISBN 978 0 580 54971 7

The following BSI references relate to the work on this standard:
Committee reference B/525/10 and B/525/31
Draft for comment 

07/30128138 DC

Publication history

First published May 2008

Amendments/corrigenda issued since publication

Date

Text affected

NA to BS EN 1993-1-9:2005

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

© BSI 2008 •

i

NA to BS EN 1993-1-9:2005

Contents

Introduction   1

NA.1

Scope   1

NA.2

Nationally Determined Parameters   1

NA.3

References to non-contradictory complementary 
information   5

Bibliography   6

List of tables
Table NA.1 – Minimum required fatigue strength   2
Table NA.2 – Recommended *

Ff

 for safe life design   3

Summary of pages
This document comprises a front cover, an inside front cover, 
pages i and ii, pages 1 to 6, an inside back cover and a back cover.

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

NA to BS EN 1993-1-9:2005

ii

• © BSI 2008

This page deliberately left blank

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

© BSI 2008 •

1

NA to BS EN 1993-1-9:2005

National Annex (informative) to 

BS EN 1993-1-9:2005, Eurocode 3 – Design of 

steel structures – Part 1-9: Fatigue

Introduction

This National Annex has been prepared by BSI Subcommittee B/525/10, 
Bridges, in consultation with B/525/31, Structural use of steel. In the 
UK it is to be used in conjunction with BS EN 1993-1-9:2005.

NA.1 Scope

This National Annex gives:
a) the UK decisions for the Nationally Determined Parameters 

described in the following clauses and subclauses of 
BS EN 1993-1-9:2005:

1.1(2)

Clause 2(2)

Clause 2(4)

Clause 3(2)

Clause 3(7)

Clause 5(2)

6.1(1)

6.2(2)

7.1(3)

7.1(5)

Clause 8(4)

b) references to non-contradictory complementary information.

NA.2 Nationally Determined Parameters

NA.2.1

Material and execution tolerances and 
information on inspection requirements for 
fabrication [BS EN 1993-1-9:2005, 1.1(2)]

NA.2.1.1

Material and execution tolerances

Until such time as BS EN 1090-2 is published, the rules are applicable 
to structures where execution conforms to either BS 5400-6:1999 for 
bridges or BS 5950-2:2001 for buildings. Note that, where 
BS 5400-6:1999 makes reference to minimum class requirements D, E 
and F, Unspecified, these may be taken to refer to a minimum 
requirement for the value of %

σ

c

 = 91 N/mm

2

, 80 N/mm

2

, 63 N/mm

2

 

and 56 N/mm

2

 respectively. For additional guidance see NA.3.

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

NA to BS EN 1993-1-9:2005

2

• © BSI 2008

NA.2.1.2

Information on inspection requirements for 
fabrication

For the safe life method of assessment, special inspection and testing 
requirements for welds, cut edges and plain surfaces should be provided 
on drawings for all applications where the minimum required fatigue 
strength exceeds the relevant value of 

Δσ

c

 in Table NA.1.

For additional guidance see NA.3.

NA.2.2

Fatigue loading models 
[BS EN 1993-1-9:2005, Clause 2(2)]

NA.2.2.1

Sources of fatigue loading

All sources of fluctuating stress in the structure should be identified and 
should be obtained from the relevant parts of BS EN 1991. For fatigue 
loading not covered in BS EN 1991 the following should receive 
particular attention:

a) superimposed moving loads, including vibrations from machinery 

in stationary structures;

b) environmental loads such as wind, waves, etc.;

c) acceleration forces in moving structures;

d) temperature changes.

Where no published data for live loading exist, the partial safety factors 
for fatigue load intensity for safe life design should take into account 
the degree of confidence in the prediction of the design load spectrum 
from the available data. Recommended values of 

γ

Ff

 are given in 

Table NA.2.

Table NA.1

Minimum required fatigue strength

Detail type according to BS EN 1993-1-9 Fatigue strength levels, 

Δσ

Table

Detail numbers

N/mm

2

 

8.1

1, 2, 3, 4

>125

8.2

1, 2, 3, 4, 5, 6, 7, 10, 11

>90

8.3

1, 2, 4, 5, 7, 19

>80

8, 10

>71

3, 6

>63

8.4

4

>80

8.8

5

>80

NOTE    Minimum required fatigue strength is the value of ¹c that would 

just achieve compliance with BS EN 1993-1-9:2005, Clause 

8.

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

© BSI 2008 •

3

NA to BS EN 1993-1-9:2005

Reference to guidance on determination of specific fatigue loading 
models is given in NA.3.

NA.2.3

Determination of fatigue strength from tests 
[BS EN 1993-1-9:2005, Clause 2(4)]

Reference to guidance on determination of specific fatigue strength data 
from tests is given in NA.3.

NA.2.4

Provisions for in-service inspection programmes 
[BS EN 1993-1-9:2005, Clause 3(2)]

In the event that the damage tolerant assessment method is to be used, 
the following provisions apply.
a) The designer should be satisfied that the Maintaining Authority for 

the structure is aware of the practical requirements and the likely 
costs of provision of access, the inspection itself, possible repair 
and temporary loss of service, prior to approval being given.

b) Any potential fatigue crack initiation sites should be on or close to 

a surface which will be readily accessible in service.

c) The method or methods of inspection should be specified for each 

potential fatigue initiation site. Inspection for fatigue cracking 
requires more sophisticated techniques than are used for normal 
principal inspections.

d) The minimum size of detectable fatigue crack should be specified 

for each initiation site, taking into account the capability of the 
methods in c).

e) The maximum tolerable size of fatigue crack (using fracture 

mechanics) for fracture under ULS loading should be calculated.

f) The time taken for the fatigue crack to grow from the minimum 

detectable size in d) to the fracture tolerable size in e) should be 
calculated by fracture mechanics using upper bound crack growth 
data and the upper bound fatigue loading. 

g) The maximum interval between inspections should be not more 

than half the time calculated in f). This may be less than the 
interval between principal inspections.

h) Guidance should be given on any requirements for taking the 

structure out of service or increasing the inspection frequency in 
the event that cracks are detected.

Table NA.2

Recommended 

γ

Ff

 

for safe life design

Number of standard 
deviations on load 
intensity

Value of 

γ

Ff

0 standard deviations 

A)

+2 standard deviations 

A)

0

1,5

1,4

+1

1,3

1,2

+2

1,1

1,0

A)

Number of standard deviations on number of cycles.

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

NA to BS EN 1993-1-9:2005

4

• © BSI 2008

i)

Viable schemes should be drawn up for repair, strengthening or 
replacement of the member where fatigue cracks have been 
detected.

j)

A maintenance manual should be provided to the maintaining 
authority at the time of commissioning of the structure, giving 
details of the items in c), g), h) and i).

NA.2.5

Assessment method, definition of class of 
consequence and partial factor for fatigue 
strength [BS EN 1993-1-9:2005, Clause 3(7)]

NA.2.5.1

Assessment method

Steel structures subject to fatigue loading should be assessed using the 
safe life method, unless otherwise agreed with the Maintaining 
Authority.

NA.2.5.2

Classes of consequences

Unless otherwise specified in the project specification, all steel 
structures subjected to fatigue should be consequence class CC2 
according to BS EN 1990:2002, Annex B. If consequence class CC1 
or CC3 is specified, the appropriate K

F1

 factors should also be applied. 

The values in BS EN 1990:2002, Annex B are recommended.

NA.2.5.3

Partial factor for fatigue strength

For steel structures assessed for safe life using the detail categories 
given in BS EN 1993-1-9:2005, Tables 8.1 to 8.10, and the fatigue 
loading in BS EN 1991-2, a value of 

γ

Mf

 = 1.1 should be used 

irrespective of consequence class in BS EN 1990:2002. For additional 
guidance see NA.3.

NA.2.6

Stress limitations for Class 4 sections 
[BS EN 1993-1-9:2005, Clause 5(2)]

The effects of excessive repeated non-linear out of plane deflection in 
flat panels might be neglected if the slenderness of plates meets 
criterion (2) of BS EN 1993-2:2006, 7.4.

NA.2.7

Use of nominal, modified nominal and 
geometric stress ranges 
[BS EN 1993-1-9:2005, Clause 6.1(1)]

Reference to guidance on determination of stress ranges is given 
in NA.3.

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

© BSI 2008 •

5

NA to BS EN 1993-1-9:2005

NA.2.8

Design value of nominal stress range 
[BS EN 1993-1-9:2005, Clause 6.2(2)]

Where no 

λ

i

 values are given it is not possible to calculate the value 

of 

Δσ

E,2

. In such cases the verification format should be based 

on damage accumulation equation A.1, given in 
BS EN 1993-1-9:2005, A.5(1), and damage accumulation expression 
A.2, given in BS EN 1993-1-9:2005, A.6(1), using the most 
comprehensive load model available. For additional guidance see NA.3.

NA.2.9

Verification of fatigue strength category 
[BS EN 1993-1-9:2005, Clause 7.1(3)]

Verification of a fatigue strength category for a particular application 
by testing is permitted provided that it is evaluated in accordance with 
BS EN 1993-1-9:2005, 7.1(3), Note 1. For additional guidance 
see NA.3.

NA.2.10

Fatigue strength categories for details not 
covered by Tables 8.1 to 8.10 or Annex B 
[BS EN 1993-1-9:2005, Clause 7.1(5)]

Fatigue strength categories for details not covered by BS EN 1993-1-9 
should be given for individual projects.

NA.2.11

Use of Annex A 
[BS EN 1993-1-9:2005, Clause 8(4)]

NA.2.11.1

Loading events

Reference to guidance on determining fatigue loading models is given 
in NA.3.

NA.2.11.2

Cycle counting

Reference to guidance on the procedure for cycle counting by the 
reservoir method is given in NA.3.

NA.3 References to non-contradictory 

complementary information

Complementary guidance on fatigue is given in PD 6695-1-9.

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

NA to BS EN 1993-1-9:2005

6

• © BSI 2008

Bibliography

For dated references, only the edition cited applies. For undated 
references, the latest edition of the referenced document (including any 
amendments) applies.
BS 5400-6:1999, Steel, concrete and composite bridges – Part 6: 
Specification for materials and workmanship, steel
BS 5950-2:2001, Structural use of steelwork in building – Part 2: 
Specification for materials, fabrication and erection – Rolled and 
welded sections
PD 6695-1-9, Recommendations for the design of structures 
to

 

BS EN 1993-1-9

BS EN 1990:2002, Eurocode – Basis of structural design
BS EN 1991, Eurocode 1 – Actions on structures
BS EN 1993-2:2006, Eurocode 3 – Design of steel structures – 
Part 2: Steel bridges

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

This page deliberately left blank

NA to BS EN 1993-1-9:2005

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI

background image

BSI – British Standards Institution

BSI is the independent national body responsible for preparing British Standards. 
It presents the UK view on standards in Europe and at the international level. 
It is incorporated by Royal Charter.

Revisions

British Standards are updated by amendment or revision. Users of British Standards 
should make sure that they possess the latest amendments or editions.
It is the constant aim of BSI to improve the quality of our products and services. 
We would be grateful if anyone finding an inaccuracy or ambiguity while using this 
British Standard would inform the Secretary of the technical committee responsible, 
the identity of which can be found on the inside front cover. 
Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures that 
subscribers automatically receive the latest editions of standards.

Buying standards

Orders for all BSI, international and foreign standards publications should be 
addressed to Customer Services. Tel: +44 (0)20 8996 9001. 
Fax: +44 (0)20 8996 7001. Email: orders@bsi-global.com. Standards are also 
available from the BSI website at http://www.bsi-global.com.
In response to orders for international standards, it is BSI policy to supply the BSI 
implementation of those that have been published as British Standards, unless 
otherwise requested.

Information on standards

BSI provides a wide range of information on national, European and international 
standards through its Library and its Technical Help to Exporters Service. Various 
BSI electronic information services are also available which give details on all its 
products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. 
Fax: +44 (0)20 8996 7048. Email: info@bsi-global.com.
Subscribing members of BSI are kept up to date with standards developments and 
receive substantial discounts on the purchase price of standards. For details of these 
and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. 
Fax: +44 (0)20 8996 7001. Email: membership@bsi-global.com.
Information regarding online access to British Standards via British Standards 
Online can be found at http://www.bsi-global.com/bsonline.
Further information about BSI is available on the BSI website at 
http://www.bsi-global.com.

Copyright

Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of 
the publications of the international standardization bodies. Except as permitted 
under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, 
stored in a retrieval system or transmitted in any form or by any means – electronic, 
photocopying, recording or otherwise – without prior written permission from BSI.
This does not preclude the free use, in the course of implementing the standard, of 
necessary details such as symbols, and size, type or grade designations. If these 
details are to be used for any other purpose than implementation then the prior 
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.
Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.
Email: copyright@bsi-global.com.

NA to BS EN 1993-1-9:2005

389 Chiswick High Road
London
W4 4AL

Licensed copy: BSI USER 06 Document Controller, Midmac Contracting Co. W.L.L, Version correct as of 05/06/2011 14:53, (c) BSI


Document Outline