background image

S

TERLING POWER  PRODUCTS  LTD

86A Blackpole Trading Estate West

Worcester, WR3 8TJ

England

Tel.: +44 (0)1905 452105

Fax: +44 (0)1905 458836

Email: help@sterling-power.com

Copyright 2005 by Sterling Power Products Ltd. Copying and reprinting not allowed. Changes and errors excepted.

Wiring Diagram

for connecting a S

TERLING

 DAR12 or PDAR advanced regulator

to a Prestolite 110A alternator

Set Sterling advanced regulator to 

NEGATIVE

 field control!

B+

L+/D+

(yellow + brown)

NEGATIVE

(2x black)

DF 

(white)

Temperature

Sensor (PDAR)