CLP3521 3621 3626 TechnicalBulletin 20090925

background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 01 / Firmware Upgrade (Ver.002.001)

SB-8688/M

Date: 16-01-2009


T

OPIC

:

The Firmware is upgraded as follows.

C

ONTENT OF

C

HANGES

:

When system setting of printer is changed in the Command Center, F46F error might occur if certain data is
printed with the PCLXL set in the KX driver.

Program No.

Check SUM

Ver.

Status Date

Remarks

DL_CTRL_2HN -

-

2HN_3000.002.001.bin 278e

-

System

2HN_3100.001.010.hex 1704

002.001

2008.12.01

-

Current Version: 001.004

R

EFERENCE

:

The picture below shows the printer system display (administrator mode) in the Command Center.

1/2




















Please press the Submit button once.

background image

2/2


Field Measure: If F46F error occurred, please upgrade the controller firmware. Afterwards, please press the

Submit button only once on the printer system display (administrator mode) in the Command Center.


Serial Nos. of Affected Machine:
From December 2008 production

background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3426

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 02 / Parts List Correction

SB-8708/M

Date: 06-02-2009


T

OPIC

:

Correction: Change of Fig. number and Ref. number.

The following part numbers described in the Parts List are corrected.

[Wrong] [Correct]

Fig.

Ref.

Part No.

Description

Part No.

Description

Remarks

5 12

302HL09090

2HL09090

CURSOR RIGHT

302HL94070

2HL94070

CURSOR RIGHT PF ASSY 2HL SP

CT-500

5

31

303K809420

3K809420

CURSOR RIGHT PF

302HN94300

2HN94300

CURSOR RIGHT PF ASSY 2HN SP

CT-501
CT-502

5

31

303K809420

3K809420

CURSOR RIGHT PF

303K894060

3K894060

CURSOR RIGHT PF

ASSY SP

CT-503

1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 03 / Parts List Correction (Fig. 14)

SB-8706/M

Date: 19-02-2009


T

OPIC

:

The following part numbers described in the Parts List are corrected.

Wrong

Correct

Fig.

Ref.

Part No.

Description

Part No.

Description

14 9

302HN00040

2HN00040

ID SENSOR ASSY

302HN94320

2HN94320

ID SENSOR ASSY SP

14 19

302HL01070

2HL01070

P.W.BOARD ASSY ENGINE WITH

SOFTWARE(E)

(21/23ppm 250sheet)

302HL01100

2HL01100

P.W.BOARD ASSY ENGINE WITH

SOFTWARE(E)(21/23ppm 250sheet)

14 19

302HM01050

2HM01050

P.W.BOARD ASSY ENGINE WITH

SOFTWARE(E)

(21/23ppm 500sheet)

302HM01080

2HM01080

P.W.BOARD ASSY ENGINE WITH

SOFTWARE(E)(21/23ppm 500sheet)

14 19

302HN01180

2HN01180

P.W.BOARD ASSY ENGINE WITH

SOFTWARE(E)

(26/28ppm 500sheet)

302HN01270

2HN01270

P.W.BOARD ASSY ENGINE WITH

SOFTWARE(E)(26/28ppm 500sheet)

1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 04 / Parts List Correction

SB-8755/M

Date: 13-03-2009


T

OPIC

:

The following part numbers described in the Parts List are corrected.

Wrong

Correct

Fig. Ref. Part No.

Description

Part No.

Description

14 18 2HN94140

SOLENOID FD ASSY SP

2HN94220 SOLENOID FD ASSY CLN SP

14 105 E0025180 SPRING PIN/M2.5 X 18 S-BLK

Deleted

13 103 E0025140

SPRING PIN 2.5 X 14

Deleted

1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521

CLP 3621
CLP 3626

TA
TA
TA

CLP 4521

CLP 4621
CLP 4626



TB 05 / Change: SPRING EARTH and WORKPLATE LIFT

SB-8757/M

Date: 13-03-2009


Only CLP 3621, CLP 3626 /

CLP 4621, CLP 4626


T

OPIC

:

Shape of SPRING EARTH and WORKPLATE LIFT is changed → From February 2009 production on.

When fitting the cassette without paper, squeak noise may occur in between SPRING EARTH and
WORKPLATE at paper lift motion.
As the measures, shape of SPRING EARTH is changed and NIGREX 568 grease is applied,
Shape of WORKPLATE LIFT is changed to form a cutout.

PAPER CASSETTE

Shape of

SPRING EARTH is changed

1/2







Before

After

Grease is applied to contact with SHAFT WORKPLATE




Shape of

WORKPLATE LIFT is changed












WORPLATE LIFT

SHAFT WORPLATE

SPRING EARTH

Before

After

Cutout is formed

background image

2/2


Q’ty

Compatibility

No

Old Part

No.

New Part

No.

Description

Old

New Old New

SP

Remarks

1 2HN09370 2HN09371 SPRING

EARTH

1

1

1 1 O 1*

2 2HN09140 3K809490 WORK PLATE LIFT

1

1

1 1 O 1*

1*:When changing SPRING EARTH and WORK PLATE LIFT, please change a set from the old part to the new pats at the same time.

Parts with [O] indicates regular maintenance parts. "+" Mark at the head of the description means it is a components parts.

background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 06 / Shape of LEVER CAM MFP is changed.

SB-8783/M

Date: 06-04-2009


T

OPIC

:

For strength up ,change of LEVER CAM MPF

From February 2009 production on.

Shape of LEVER CAM MPF is changed to improve the strength.
According to this change, part code is changed as follows.




FRAME MPF ASSY

LEVER CAM

Before

After












Q’ ty

Compatibility

No

Old Part

No.

New Part

No.

Description

Old New Old New

SP

Remarks

1 2HN08180 2HN08181 LEVER CAM MFP

1

1

- O

O

• Parts with [O] indicates regular maintenance parts.

1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 07 / Engine firmware upgrade (Ver.005.003)

SB-8774/M

Date: 06-04-2009


T

OPIC

:

Engine firmware is upgraded to correct the failure as follows.

1. Paper jam is corrected that occurs in case paper feed from the duplex unit delays, calibration is requested

during retrial of the paper feed in continuous duplex printing and the next paper enters the duplex unit.

2.Paper jam is corrected that may rarely occur in case toner replacement is requested when paper is feed from

the bottom of the full set of paper feeders in continuous duplex printing of letter size.


CLP 3521 /

CLP 4521

Program No.

Check SUM

VER.

Status Date

Remarks

ENGINE

S2HL_1000005003.x 2dbe

005.003

2009/2

-

Current Version: 004.001


CLP 3621 /

CLP 4621

Program No.

Check SUM

VER.

Status Date

Remarks

ENGINE

S2HM_1000005003.x 6c22

005.003

2009/2

-

Current Version: 004.001


CLP 3626 /

CLP 4626

Program No.

Check SUM

VER.

Status Date

Remarks

ENGINE

S2HN_1000005003.x 0cfb

005.003

2009/2

-

Current Version: 004.001



Field Measure:

If the problem arises, please upgrade firmware.

Serial Nos. of affected Machine: From February 2009 production on.

1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 08 / Change: ACTUATOR MPF

SB-8861/M

Date: 01-07-2009


T

OPIC

:

Shape of ACTUATOR MPF is changed to improve margin for sensing the MP tray paper when feeding thin media.
According to this change, following part number is changed.










ACTUATOR MPF

0.7mm is added.



Q’ ty

Compatibility

No

Old Part

No.

New Part

No.

Description

Old New Old New

SP

Remarks

1 2HN06120 2HN06121 ACTUATOR

MPF

1

1

O O O

Parts with “O” indicates regular maintenance parts.


Classification

Entire Stock Rework

In-Field modification at next visit

In-Field modification by case

No modification necessary

Field Measure: Please use the new type part for the next development machine.

Serial Nos. of Affected Machine: From the production in (May), 2009 on* (Plan)

* The above is the plan at the present moment.

Please note that there is a possibility of change after giving this information.


1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 09 / Parts List is corrected (Fig.11 Fuser Section)

SB-8884/M

Date: 08-07-2009


T

OPIC

:

Following parts cannot be changed in the field since dedicated jigs are necessary for parts assembly around the
roller heat. Therefore, following parts are deleted from the parts list.

Fig.11 FUSER SECTION






















Ref Part

No.

Alternative.

Description

Q’ty

Remarks

3

302FZ25300

2FZ25300

BEARING 20 32

2

deleted

6 302HN25010

2HN25010 ROLLER

HEAT

1

deleted

10

302HN25050

2HN25050

PLATE SIDE L

1

deleted

11

302HN25060

2HN25060

PLATE SIDE R

1

deleted

12 302HN25070

2HN25070 PLATE

STAY

1

deleted

36

302HN25410

2HN25410

SEPARATOR ASSY

1

deleted

37

302HN25420

2HN25420

SPRING SEPARATOR L

1

deleted

39

302HN25440

2HN25440

SPRING SEPARATOR R

1

deleted

43 302HN25480

2HN25480 SCREW

ADJUSTMENT 2

deleted

62 5MVM180XN002

2D920030

BUSH

FUSER

2

deleted

1/1


background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 10 / Noise in the primary transfer unit

SB-8895/M

Date: 20-07-2009


T

OPIC

:

Noise may be rarely heard from the primary transfer unit. It is from friction between the gear and attaching boss.
As measures, grease is added to following place.

According to the grease added, parts code is not changed

Please refer to the attached procedures to add the grease.















PULLEY P14 S3M BELT

Added grease















1/2


background image

TR-540 / 560

ABOUT GREASE COATING

:






2/2
















Reassemble after applying grease.

Q’ ty

Compatibility

No

New Part

No.

Description

Old New

Old New

SP

Remarks

1

M014000080

GREASE Molykote EM-50LP

-

1

O O

-

Parts with “O” indicates regular maintenance parts. "+" Mark at the head of the description means it is a components parts.



Classification

Entire Stock Rework

In-Field modification at next visit

In-Field modification by case

No modification necessary

Field Measure: According to the grease added, parts code is not changed

Serial Nos. of Affected Machine: CLP 3521 /

CLP 4521

J XFF9602441 and up.

CLP 3621 /

CLP 4621

J XFJ9602149 and up.

CLP 3626 /

CLP 4626

J XFM9600970 and up.

1.) Take off clips and then gears

2.) Take off belt and then gear

3.) Grease (Pos1) is added

background image

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621

CLP 3626

TA
TA
TA

CLP 4521
CLP 4621

CLP 4626



TB 11 / LEVER LOCK ENVELOPE - Default Setting

SB-9011/M

Date: 23-09-2009



Only

J CLP 3521, CLP 3621 /

CLP 4521, CLP 4621



T

OPIC

:

Conventionally, the fuser pressure setting with the envelope switch was set to the envelope mode (right side) at
factory.
This is to avoid deformation of the fuser roller after prolonged storage with less fuser pressure applied to the
roller. Accordingly, if normal paper is used, the envelope switch had to be manually switched to the normal
mode (left side).

Since it was confirmed that the fuser pressure with normal mode would not deform the fuser roller, the printer is
now shipped with the envelope switch set to the normal mode (left side).









LEVER LOCK ENVELOPE



<Before> Set to envelope mode (right side)
<After>

Set to normal paper mode (left side)




Classification

Entire Stock Rework

In-Field modification at next visit

In-Field modification by case

No modification necessary

Field Measure: ----------------------------


Serial Nos. of Affected Machine: From the September 2009 production

1/1

background image

1/2

Technical Bulletin

UTAX
UTAX
UTAX

CLP 3521
CLP 3621
CLP 3626

TA
TA
TA

CLP 4521
CLP 4621
CLP 4626



TB 12 / T0 parameter (MP tray mode)

Dör/M

Date: 23-09-2009



T

OPIC

:


With the new printer series below, the T0 parameter (MP tray mode) does no longer exist.

N

OTE

:


With the firmware revision below, a similar functionality is available now.

SYSTEM

J 2HN.3000.005.016


For this purpose the following two settings in the printer menu should be applied accordingly:

Š In "Print Settings" the "MP tray" has to be defined as default tray.

Š In "Device Common" the "Error Handling" for "MP Tray Empty" has to be set to "Off"