IM PAC YG81TB WT05422X02 Apr 2009

background image

- 1 -

• Before installing the Mounting attachment B type, please read the following safety precautions carefully to ensure proper

installation.

• Observe the following precautions to ensure safety.
• The following symbols are used in this manual to indicate the type and severity of potential consequences that may result when

given instructions are not followed exactly as stated.

• After the completion of installation, perform a test run to confirm proper operation.
• Retain this manual for future reference. When the unit is reinstalled or repaired, make this manual available to those who provide

these services. Make sure that the manual is passed on to any future air condition system users.

1 Safety Precautions

WARNING

Indicates a risk of death or serious injury.

CAUTION

Indicates a risk of injury or damage to the product.

WARNING

CAUTION

Air-conditioner Control System Optional Parts
Mounting attachment B type for use with AG-150A

PAC-YG81TB

Installation Manual

Applicable
Model

Centralized Controller

AG-150A

Only a dealer or qualified technician should replace
the unit.
Improper replacement by an unqualified person may result
in electric shock or fire.

The Mounting attachment B type should be installed
on a surface that is strong enough to support the
weight of the unit.
If the Mounting attachment B type is installed on a surface
that lacks the strength to support it, it may fall and cause
injury.

Do not attempt to modify or repair the Mounting
attachment B type.
Modification or improper repair may result in electric shock
or fire. Consult your dealer when repairs are necessary.

Install the Mounting attachment B type properly
according to the instructions detailed in this
Installation Manual.
Improper installation by an unqualified person may result in
electric shock or fire.

Electric work must be performed by authorized
personnel according to the local regulations and the
instructions detailed in the Installation Manual.
Inadequate circuit capacity or improper installation may
result in electric shock or fire.

Ask your dealer or an authorized technician to move
the Mounting attachment B type.
Improper installation by an unqualified person may result in
electric shock or fire. Consult your dealer or a qualified
technician.

Do not install the Mounting attachment B type where
there is a risk of leaking flammable gas.
If the leaked gas accumulates around the Electric Box, it
may ignite and cause an explosion.

Do not use the Mounting attachment B type in an
environment that has high concentrations of oil,
steam, or sulfuric gas.
These substances may have adverse effects on the
performance of the Mounting attachment B type or
damage its parts.

Seal the wire access holes with putty to prevent dew,
water, and insects from entering to avoid electric
shock.

Do not install this Mounting attachment B type in a
place that has the potential for steam, such as a
bathroom or kitchen.
Steam may cause an electric shock or a unit malfunction.

Do not install this Mounting attachment B type where
an acid, alkaline solution, or special chemical spray is
used frequently to avoid electric shock or malfunction.

Keep the cables from coming in direct contact with the
edges of the wire access holes.
If the cables are damaged, they may cause electric shock
or fire.

This Mounting attachment B type is for exclusive use
with the AG-150A and cannot be used with other
devices.

background image

- 2 -

The Installation Manual and the parts listed below are included with the package.
* Leave the Mounting attachment B type in the package until ready to install to protect it from damage.

The following parts are necessary to mount the Mounting attachment B type (PAC-YG81TB) on the wall.

Use screws that are suitable for the wall type.
The weight of the AG-150A including the Mounting attachment B type (PAC-YG81TB) is 2.7 kg (6.0 lbs).
Use screws with the head size of between 7.0 and 8.8 mm (5/16 and 6/16 in).

2 Parts List

Name

1

Mounting attachment B type
(PAC-YG81TB)

2

AG-150A mounting screws

3

LAN link-up cable

Quantity

1

4

1

Shape

3 Field-supplied parts

Name

1

Wall mounting screws (M4)

Quantity

6

4 External Dimensions

Roundhead screws M4×16

299 (11-

13/16

)

184

(7-

1 /

4

)

250 (9-

7/8

)

167

(6-

5 /

8

)

65 (2-

9/16

)

226 (8-

15/16

)

120

(4-

3 /

4

)

200 (7-

7/8

)

50

(2)

40 (1-

5/8

)

20

(

13

/ 16

)

UP

113 (4-

1/2

)

9 (

3/8

)

4.5 (

3/16

)

Unit: mm (in)

Wall mounting screw hole (6)

background image

- 3 -

1. Required installation space

Install the Mounting attachment B type (PAC-YG81TB) where the space indicated in the figure below can be secured.

The cable can be routed either from the top or the bottom.

1. To route the cable from the top

(1) Cut out the knockout hole on the Mounting attachment B type (PAC-YG81TB) at the top with a nipper for the cable

(the thin part of the plastic).

(2) Sand the cut surface of the knockout hole smooth.

5 Selecting an Installation Site

6 Installation

CAUTION

Any rough edges that are left may damage the cable and cause electric shock or fire.

Mounting attachment B type (PAC-YG81TB)

Unit: mm (in)

30 (1-3/16)

151 (6)

184 (7-1/4)

299 (11-13/16)

30 (1-3/16)

121 (4-13/16)

UP

NOTE
Install the Mounting attachment B type (PAC-YG81TB)
so that the arrow (ÇUP) on the back of it points up.

background image

- 4 -

(3) Install the Mounting attachment B type (PAC-YG81TB) with

the six mounting screws (field-supplied).
Use screws that are suitable for the wall type.
Install it on the surface strong enough to support its weight.

(4) Push the cable through the knockout hole.

(5) Remove AG-150A surface cover.

NOTE
Install the Mounting attachment B type (PAC-YG81TB)
so that the arrow (ÇUP) on the back of it points up.

Wall

Wall

Insert a flat-tip screwdriver in the holes
indicated and move the handle up to
remove the cover.

background image

- 5 -

(6) Connect the cable to the AG-150A.

Refer to the AG-150A Installation Manual for details.

(7) If the AG-150A is not always connected to the LAN, connect the supplied LAN link-up cable to the LAN connector.

(* If the AG-150A is always connected to the LAN, connect the LAN cable (field supplied) via a HUB and the LAN link-up
cable is not required.)

(8) Securely seal the cable lead-in port with putty to prevent dew, water and insect, etc. from entering.

CAUTION

* When routing the cable from the top of the controller, let the cable hang down below the connector before connecting it to

the terminal block or connector as shown in the figure below to prevent water from running down the cable and cause
electric shock or fire.

Terminal block or
connector

Good example

Bad example

M-NET
transmission
cable

Shield

DC power cable

Back of controller

Function earthing
(ground) cable

LAN

LAN link-up cable (supplied)

Seal with putty

background image

- 6 -

(9) Install the AG-150A with the four screws that are supplied.

If the LAN link-up cable is used, place it inside the Mounting attachment B type.

(10) Attach the cover on the AG-150A.

background image

- 7 -

2. To route the cable from the bottom

(1) Cut out the knockout hole on the Mounting attachment B type (PAC-YG81TB) at the bottom with a nipper for the cable.

(2) Sand the cut surface of the knockout hole smooth.

(3) Install the Mounting attachment B type (PAC-YG81TB) with

the six mounting screws (field-supplied).
Use screws that are suitable for the wall type.
Install it on the surface strong enough to support its weight.

CAUTION

Any rough edges that are left may damage the cable and cause electric shock or fire.

NOTE
Install the Mounting attachment B type (PAC-YG81TB) so that
the arrow (ÇUP) on the back of it points up.

Knockout hole

NOTE
Install the Mounting attachment B type (PAC-YG81TB)
so that the arrow (ÇUP) on the back of it points up.

Wall

background image

- 8 -

(4) Push the cable through the knockout hole.

(5) Remove AG-150A surface cover.

(6) Connect the cable to the AG-150A.

Refer to the AG-150A Installation Manual for details.

Insert a flat-tip screwdriver in the holes
indicated and move the handle up to
remove the cover.

M-NET
transmission
cable

Shield

DC power cable

Back of controller

Function earthing
(ground) cable

background image

- 9 -

(7) If the AG-150A is not always connected to the LAN, connect the supplied LAN link-up cable to the LAN connector.

(* If the AG-150A is always connected to the LAN, connect the LAN cable (field supplied) via a HUB and the LAN link-up
cable is not required.)

(8) Install the AG-150A with the four screws that are supplied.

If the LAN link-up cable is used, place it inside the Mounting attachment B type.

(9) Attach the cover on the AG-150A.

LAN

LAN link-up cable (supplied)

background image

- 10 -

There is a maintenance access panel at the bottom of the Mounting attachment B type.
The maintenance access panel is used for maintenance purpose when the AG-150A is not always connected to the LAN.

To open the maintenance access panel
(1) Unscrew the four screws on the panel with a Phillips driver.

(2) Remove the panel by placing your finger on the dent at right and pulling it down.

If the AG-150A is not always connected to the LAN, connect a LAN cable to the LAN link-up cable through this maintenance access
panel to upgrade the AG-150A software as necessary.

7 Access panel

Bottom view

Bottom view

Dent

LAN cable

PC

LAN link-up cable

background image
background image

HEAD OFFICE: TOKYO BLDG. , 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V.

HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K.

WT05422X02
Printed in Japan
Recycled Paper

Please be sure to put the contact address/telephone number on

this manual before handing it to the customer.


Wyszukiwarka

Podobne podstrony:
IM PAC YG83UTB WT05420X01 Apr 2009
IM PAC SC51KUA J WT05372X03 Apr 2009
IM PAC IF011B E IF012B E BH79D099H02 GB 09 2009
IM PAC SE51CRB WT03594X05 GB Aug 2009
Kwasy karboksylowe Apr 2009(1)
IM PAC KE07DME WT05243X01 2007
IM PAC SC36NA E(WT04936X01) GB
0300122810 Yale University Press One State Two States Resolving the Israel Palestine Conflict Apr 20
IM PAC SE51CRA WT02699X01 GB 2005
IM PAC SA1ME E RG79V563H01 2007
IM PAC YG66DCA WT04977X01 EN 2007
IM PAC YG63MCA WT04975X01 EN 2007
IM PAC SE55RA E WT02925x01 pd
IM PAC YG60MCA WT04973X01 EN 2007
IM PAC AK31 51BC BG79U439K08 Sep 2010
IM PAC AH125 140 250M H WT04980X02 GB 2007
IM MAC 399IF E SG79Y416H05 Sep 2009

więcej podobnych podstron