EQUIPMENT
Gloves, sterile
Betadine stick swabs
New drainage bag, sterile
PROCEDURE
Change bag when
3
/
4
full. Prevents overfilling of drainage
bag.
1. Gather equipment. Promotes organization and effi-
ciency.
2. Wash hands. Reduces transmission of microorganisms.
3. Prepare connection between tubing and bag by cleans-
ing with betadine swab sticks. Reduces transmission of
microorganisms.
4. Allow to dry. Betadine must dry to be effective.
5. Ensure clamps on tubing between drip chamber and
bag are closed. To prevent CSF from entering tubing.
6. Open package containing new bag maintaining sterile
technique.
7. Put on sterile gloves. Reduces transmission of microor-
ganisms.
8. Remove old bag from tubing and attach new bag.
9. Dispose of old bag containing CSF in biohazard con-
tainer. Consistent with guidelines for handling bodily
fluids.
10. Remove gloves. Wash hands. Reduces transmission of
microorganisms.
DOCUMENTATION
1. Bag change.
85
Copyright © 2007 by Thomson Delmar Learning, a division of Thomson Learning, Inc. All rights reserved.
SKILL 37
SKILL 37
EVD: Changing the Drainage Bag