123 20 System K lacznik C I


123. FREYSSINET C AND K SYSTEMS ANCHORAGES
K System: C I Couplers (Tromplate)
PAGE 1/3
C
x 1
Ø H
x 2
leak proof joint
x 3
x 4
R
Ø P
monostrand prolongator
1 int.
Ø
sheath
PPC 123/20-02.95
A x B
123. FREYSSINET C AND K SYSTEMS ANCHORAGES
K System
COUPLER C I (TROMPLATE) / COUPLER C I (PLATE + TRUMPET)
C I  7 K 13 C I  12 K 13 C I  7 K 15 C I  19 K 13 C I  27 K 13 C I 37 K 13 C I 55 K 13
Dimensions in mm
C I  4 K 15 C I  12 K 15 C I  19 K 15 C I 27 K 15 C I 37 K 15
A x B 170 x 170 235 x 220 235 x 220 260 x 260 315 x 315 450 x 400 495 x 495
C 120 180 180 205 400 470 486
E 75 70
(1) Ø1int. x e Class 1 55 x 0.30 65 x 0.30 65 x 0.30 80 x 0.35 100 x 0.40 120 x 0.60 130 x 0.60
(1) Ø1int. x e Class 2 55 x 0.45 65 x 0.45 65 x 0.45 80 x 0.50 100 x 0.60 120 x 0.60 130 x 0.60
Ø H 190 254 254 300 352 440 440
Ø P 140 193 159 193 244 273 356
R 870 1220 920 1300 1350 1460 1610
(2) Whorl Ø2
10 12 12 14 16 18 20
Steel grade FeE 235
Number of convolutions 6 6 6 6 6 7 8
Ø3 ext. 200 280 280 360 440 540 640
Pitch 50 50 50 60 65 70 70
Total length 300 300 300 360 390 490 560
(2) Type of cross-wise bursting reinf. 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2
Number of layers 1 1 1 1 1 2 2
Ø of reinf. bars Steel grade FeE 235 10 12 12 14 16 14 16
b 160 200 200 240 300 360 400
s 100 120 120 150 170 210 240
q1 350 420 420 500 570 560 640
q2 260 312 312 374 426 434 496
7 K 13 12 K 13 19 K 13 4 K 15 7 K 15 12 K 15
27 K 13 37 K 13 55 K 13 19 K 15 27 K 15 37 K 15
NOTE
(1) According to standard EN 523.
(2) The helical or cross-wise hoops mentioned in this table, which resist the bursting forces of concrete in the anchorage zone, are only valid when an anchorage is isolated in a pris-
matic section element (test block) and for concrete with a cylinder strength fcmin of between 23 and 43 MPa.
 When the anchorages are grouped along one line or more, continuous reinforcement of an equivalent section has to be provided, linking all anchorages and correctly anchored
within the structure.
PAGE 2/3
COUPLER
REINFORCEMENT
HELICAL BURSTING
REINFORCEMENT
CROSS-WISE BURSTING
123. FREYSSINET C AND K SYSTEMS ANCHORAGES
K System: C I Couplers (Plate + Trumpet)
PAGE 3/3
C
E
x 1
Ø H
x 2
leak proof joint
x 3
x 4
R
Ø P
monostrand prolongator
1int.
Ø
sheath
A x B


Wyszukiwarka

Podobne podstrony:
123 System C lacznik R
123 System K lacznik C
123 System C lacznik C
123! System K lacznik R
123 System C lacznik CI
123 System C zakotwienie zwykle (2)
123 System C i K Zakotwienie bierne NE
123# System C rozmieszczanie zakotwien (2)
123 System C i K sprezenie wewnetrzne opis
123 System K zakotwienie bierne NB
123 System K zakotwienie zwykle
123 1 System C i K Sprezenie wewnetrzne
123 System C bezprzyczepnosciowy

więcej podobnych podstron