akkus polprzewodniki dsei12 12a eng
DSEI 12, 1200 V
DSEI 12 IFAVM = 11 A
Fast Recovery
VRRM = 1200 V
Epitaxial Diode (FRED)
trr = 50 ns
TO-220 AC
C
A
VRSM VRRM Type
C
V V
A
C
1200 1200 DSEI 12-12A
A = Anode, C = Cathode
Symbol Test Conditions Maximum Ratings
Features
IFRMS TVJ = TVJM 25 A International standard package
IFAVM ÿÿ TC = 100 C; rectangular, d = 0.5 11 A
JEDEC TO-220 AC
IFRM tP < 10 s; rep. rating, pulse width limited by TVJM 150 A
Planar passivated chips
Very short recovery time
IFSM TVJ = 45 C; t = 10 ms (50 Hz), sine 75 A
Extremely low switching losses
t = 8.3 ms (60 Hz), sine 80 A
Low IRM-values
TVJ = 150 C; t = 10 ms (50 Hz), sine 65 A
Soft recovery behaviour
t = 8.3 ms (60 Hz), sine 70 A
Epoxy meets UL 94V-0
I2t TVJ = 45 C t = 10 ms (50 Hz), sine 28 A2s
t = 8.3 ms (60 Hz), sine 27 A2s
Applications
TVJ = 150 C; t = 10 ms (50 Hz), sine 21 A2s
t = 8.3 ms (60 Hz), sine 20 A2s
Antiparallel diode for high frequency
switching devices
TVJ -40...+150 C
Anti saturation diode
TVJM 150 C
T -40...+150 C Snubber diode
stg
Free wheeling diode in converters
Ptot TC = 25 C 78 W
and motor control circuits
Md Mounting torque 0.4...0.6 Nm
Rectifiers in switch mode power
supplies (SMPS)
Weight 2 g
Inductive heating and melting
Uninterruptible power supplies (UPS)
Symbol Test Conditions Characteristic Values Ultrasonic cleaners and welders
typ. max.
IR TVJ = 25 C V = VRRM 250 A Advantages
R
TVJ = 25 C V = 0.8 " VRRM 150 A
R
High reliability circuit operation
TVJ = 125 C V = 0.8 " VRRM 4 m A
R
Low voltage peaks for reduced
VF IF = 12 A; TVJ = 150 C 2.2 V
protection circuits
TVJ =2 5 C 2.6 V
Low noise switching
VT0 For power-loss calculations only 1.65 V
Low losses
rT TVJ = TVJM 46.2 m
Operating at lower temperature or
space saving by reduced cooling
RthJC 1.6 K/W
RthCK 0.5 K/W
RthJA 60 K/W
t IF = 1 A; -di/dt = 50 A/ s; VR = 30 V; TVJ = 25 C 5 0 70 ns
rr
IRM VR = 540 V; IF = 12 A; -diF/dt = 100 A/ s 6.5 7.2 A
L 0.05 H; TVJ = 100 C
IFAVM rating includes reverse blocking losses at TVJM, VR = 0.8 VRRM, duty cycle d = 0.5
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions
1 - 2
Internet: Konto bankowe:
ul.Kochanowskiego 17/66, 84-200 Wejherowo http://www.akkus.com.pl Kredyt Bank SA O/Gdynia 15001881-121880020718
tel. (058) 6779192, tel. kom. 0501173793, fax (058) 6774036 info@akkus.com.pl
033
DSEI 12, 1200 V
30 3.0 30
TVJ=100°C
TVJ=100°C
A µC
A
VR=540V
VR= 540V
25 2.5 25
max.
IRM
IF=11A
IF=11A
20 2.0 20
IF=22A
IF Qr IF=22A
TVJ=25°C
IF=11A
IF=11A
TVJ=100°C
IF=5.5A
IF=5.5A
15 1.5 15
TVJ=150°C
10 1.0 10
max. typ.
5 0.5 5
typ.
0 0.0 0
A/µs
0 1 2 3 4 V 1 10 100 1000 0 100 200 300 400
A/µs
VF -diF/dt -diF/dt
Fig. 1 Forward current Fig. 2 Recovery charge versus -diF/dt. Fig. 3 Peak reverse current versus
versus voltage drop. -diF/dt.
1.4 1.0 60 1200
V
TVJ=100°C
ns
µs
VR=540V
1.2
50 1000
0.8
VFR
1.0
IF=11A
max. 40 800
IRM trr
VFR
Kf
IF=22A tfr
0.6
0.8
IF=11A
600
30
IF=5.5A
0.6
tfr
0.4
QR
400
20
0.4
0.2
10 200
0.2
TVJ=125°C
typ.
IF=11A
0
0.0 0.0 0
0 4 0 80 120 °C 160 0 100 200 300 A/µs400 0 100 200 300 A/µs 400
TJ
-diF/dt
diF/dt
Fig. 4 Dynamic parameters versus Fig. 5 Recovery time versus -diF/dt. Fig. 6 Peak forward voltage
junction temperature. versus diF/dt.
Dim. Millimeter Inches
Dimensions
Min. Max. Min. Max.
A 12.70 14.73 0.500 0.580
B 14.23 16.51 0.560 0.650
C 9.66 10.66 0.380 0.420
D 3.54 4.08 0.139 0.161
E 5.85 6.85 0.230 0.420
F 2.54 3.42 0.100 0.135
G 1.15 1.77 0.045 0.070
H - 6.35 - 0.250
J 0.64 0.89 0.025 0.035
K 4.83 5.33 0.190 0.210
L 3.56 4.82 0.140 0.190
M 0.38 0.56 0.015 0.022
N 2.04 2.49 0.080 0.115
Q 0.64 1.39 0.025 0.055
Fig. 7 Transient thermal impedance junction to case.
-
© 2000 IXYS All rights reserved
2 - 2
Internet: Konto bankowe:
ul.Kochanowskiego 17/66, 84-200 Wejherowo http://www.akkus.com.pl Kredyt Bank SA O/Gdynia 15001881-121880020718
tel. (058) 6779192, tel. kom. 0501173793, fax (058) 6774036 info@akkus.com.pl
Wyszukiwarka