APC Back UPS BK300MI,BK500MI 1


REV # DATE REVISION APPRVD
PCB B REV 2 5/24/96 PILOT AND BETA PRODUCTION RELEASE RM
PCB B REV 3 6/25/96 NO ELECTRICAL CHANGES RM
PCB D REV 5 01/08/97 ADDED D30 PAJ
NOTES:
PCB E REV 6 03/30/98 ADDED SENSE CIRCUIT PER ECO PAJ/SD
PCB F REV 7 09/25/98 REV PER COMP VALUES/DFM ISSUES PAJ/DN
1) CHECK BOMS FOR DIFFERENT VALUES (SEE TABLE 1)
PCB F REV 8 3/25/99 ADDED BK500IACH OPTION PAJ/PF
AND POPULATION OPTIONS.
HS1
F2
T1 D18 D2
1 2 1 3 2 1 2 1
UTIL_HOT IC1 BATT12V
1 12
125mA,FAST,250V,VDE,RD 1N4005 1N4005
2
D3
D4 2,1
D17
2 1
RELAYVLT
3 10
C4
1N4148
D30
4 9
D5 D6
6 7
UTIL_NTL
10VA,28VCT,120/240V
+5
+5
+12
R42 +12 +12
R1
+5
R19 R56
R61
+12 ACFAIL
+12
3
11
IC4
3
R18
+
V+ IC5 14
13 1 2 5
IC4
14 5
+
V+
10 2 11 10
V- 4
- 150K,5%,1/4W IC3
6
4
V-
7
12
-
C5
R17 350-4001
12
R37 R38 12UNFILT
+12
NOTE 1
C18
C6
J1 3
1
0.022UF,50V,5%
9
IC4
TEST
+
V+ D21
14
SW1 C19
J1
SW1 1N4148 R74
2 8
V- R58 +12
- 1 2
XFER1 XFER2
12 2 1
IFDFWRD
J1 20-OHM,5%,1/4W 150K,5%,1/4W
C1 R2
3
+5 0.001UF,100V,10%
2 1
COMP
R70
ALARMDIS XFER VOLTS
2
R55
C7 XFER1 XFER2
+5 +12
VR2 1
R49
R5 +5
1 2
196V OPEN OPEN 50K 2 1 C35 R75
1 2
XFER 470K,5%,1/4W
49.9K,1%,1/4W
184V CLOSED OPEN
6.8M,5%,1/4W
VOLTS 3 C2
2
R4
172V OPEN CLOSED
1 2 1 2
R83 R50
VR3 1 1 2
160V CLOSED CLOSED C16
200K,5%,1/4W
49.9K,1%,1/4W R48
0.1UF,50V,5%,POLY 50K
R71
1M,5%,1/4W
(500IACH)165V N/A N/A OUTPUT 20K,5%,1/4W
+12 +5 +12 +5
VOLTS
14
3
1
R86
IC7 3 1
+5 C36
2 1
R54 R3 Q17
2
15 16
Q18
2
2N2907
7
FREQUENCY 2N2907 +VIN VREF
3
2
ADJUST
+5 3 2 13
NON_INV COL_B PUSHPL2
R80
+12 C15 1 14
1 1 2 EMIT_B
PUSHPL2 R93 VR4 INV
14
1 2 1 2 9 IC6 COL_A 12
12
50K COMP PUSHPL1
470K,5%,1/4W
IC7 11
3 EMIT_A 11
1.5K,1%,1/4W
OSC_OUT
13 0.01UF,100V,5%
+12
PUSHPL1 3 6 SHUTDOWN 10
RT
7 D26 7 +CL 4
CT 360-3524B ISENSE
IC2
+12 1N4148
14 R82
R81 GND -CL
6
VCC R76 R78 R77
C
9 1 2 1 2
R47 8 5
OUT
1 2 8
2 1
IN
GND 4.7K,5%,1/4W 470K,5%,1/4W
200K,5%,1/4W
100K,5%,1/4W
C28
7
R65
R57 C27
C37
C22
1 2 +12
3
+12
+12
0.1UF,50V,5%,POLY 2 Q14
IC2
14 2N2222
5
VCC R94
IC5 IC5 C 1
3 1 2
14 14 R46
3 4 5 61 2 OUT
4
IN
GND
2.26K,1%,1/4W
7 7 100K,5%,1/4W
C21
7
R64 SW1
AMERICAN POWER CONVERSION
DESCRIPTION SHEET
TABLE 1
MODEL R115 R116 R56 R79 COMPS NOT INSTALLED 1 OF 3
SCHEMATIC BKBABY 230V
300MI 4.02K 1/4W 1% 49.9K 1/4W 1% 56.5K 1/4W 1% 110K 1/4W 1% N/A PRODUCT APCC PART #
500MI 4.75K 1/4W 1% 10K 1/4W 1% 56.5K 1/4W 1% 110K 1/4W 1% N/A
BK300MI/BK500MI VDE BABY
640-0213F
R3,R25,R37,R38,R98,
500IACH 4.75K 1/4W 1% 10K 1/4W 1% 49.9K 1/4W 1% 121K 1/4W 1%
DATE BY SCALE DWG REV
R94,SW1,J1,C27,C34,Q14
3/25/99
12/27/95 RFM E213F-08 08
2
1
2
1
33V,1/2W,5%
0.1UF,50V,5%,POLY
1N4005
1N4005
1N4005
1N4005
2
1
2
1
2
1
2
1
2
1
2
1
200K,5%,1/4W
200K,5%,1/4W
2
1
2
1
2
1
10K,5%,1/4W
66.5K,1%,1/4W
6.8M,5%,1/4W
2
1
2
1
3.3NF,50V,5%
200K,5%,1/4W
2
1
2
1
110K,1%,1/4W
237K,1%,1/4W
2
1
2
1
0.1UF,50V,5%,POLY
2
1
550-0003
550-0003
7
2
6
3
12
523K,1%,1/4W
2
1
2
1
200K,5%,1/4W
3.3NF,50V,5%
2
1
12
0.01UF,50V,20%,CER
150K,5%,1/4W
0.1UF,50V,5%,POLY
21
12
12
12
2
2
20K,5%,1/4W
0.01UF,50V,20%,CER
12
1
1
121K,1%,1/4W
2
1
2
1
470K,5%,1/4W
133K,1%,1/4W
0.01UF,100V,5%
2
1
2
1
2
1
20K,5%,1/4W
20K,5%,1/4W
2
1
2
1
12
R79
1M,5%,1/4W
2
1
100K,5%,1/4W
2
1
0.022UF,50V,5%
12
110K,1%,1/4W
0.1UF,50V,5%,POLY
0.22UF,50V,5%
2
1
550-0003
5
4
0.1UF,50V,5%,POLY
2
1
1M,5%,1/4W


Wyszukiwarka

Podobne podstrony:
APC Back UPS BK300MI,BK500MI 2
APC Back UPS BK300MI,BK500MI 3
APC BACK schemat UPS BK300MI,BK500MI
APC Back UPS 250,400,600 2
Instrukcja obsługi APC BACK UPS CS 500
Back UPS RS 550
UPS APC 2200 990 1674C PL
apc
APC SMART schemat 1000 1400
Back In The Saddle
ups howto 4 moe5mlzqv3vdbybvlzrf4tu6kzwaprjsi5bkeoy moe5mlzqv3vdbybvlzrf4tu6kzwaprjsi5bkeoy
stabilizatory i UPS

więcej podobnych podstron