C5HG08F1 - 607
REMOVAL - REFITTING HEATER
IMPERATIVE :
BEFORE ANY WORK ON THE AIR CONDITIONING CIRCUIT, OBSERVE THE RECOMMENDED PRECAUTIONS
.
1 -
SPECIAL TOOLS
[1] Hose clamp : Workshop reference (-).1512
.
2 -
REMOVAL
Drain the refrigerant circuit
.
Remove the fascia
.
Remove the ventilator conduits
.
Unclip the scuttle panel
.
Remove the pollen filter
.
Remove the 2 fittings (1) from the filter bracket (2)
.
Depressurise the cooling system
.
Clamp the heater matrix inlet and outlet pipes (3), Using the tool [1]
.
Disconnect the hoses (3)
.
Remove the fastener (4)
.
Remove the nuts (5)
.
Detach the clamp from the pressure relief valve and block the input points of the pressure relief valve and the pipes
.
Remove the 2 fittings (6) from the heater assembly on the bulkhead
.
Remove the fittings (7) from the condensation drain plate (8)
.
Disconnect the connector (9) from the blower module, Release the harness
.
WARNING :
place a receptacle under the heater matrix inlet and outlet pipes
.
Remove the heater assembly
.
3 -
REFITTING
Proceed in the reverse order to removal
.
Fit new lubricated seals on all the pipes of the air conditioning circuit which have been removed.
.
RECHARGE WITH REFRIGERANT
.
Check operation of the circuit
.