Block Describtion DI


BLOCK DESCRIPTION Strona 1 z 15
ERICSSON ///
DOCUMENT INSTRUCTION
Uppgjord - Prepared Faktaansvarig - Subject responsible Nr - No
EED/TM Anna Paintner ETX/TX/DT MYON 14/1013-FCK 114 21 Uen
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
ETX/TX/DT (H. Westlund) 1996-01-01 B
BLOCK DESCRIPTION
Contents
1 REVISION INFORMATION
2 APPLICATION
3 PURPOSE OF THIS DOCUMENT INSTRUCTION (DI)
4 BLOCK DESCRIPTION (BD)
4.1 Purpose of a Block Description
4.2 Users of a Block Description
4.3 Identification of a Block Description
4.4 Contents of a Block Description
4.5 Writing a Block Description
5 GLOSSARY
6 REFERENCES
1 REVISION INFORMATION
This is a new document instruction, which replaces the following document instructions:
Block Description; 3/1013-FCK 114 21 Uen and
Block Description Flow Chart; 4/1013-FCK 114 21 Uen.
Rev B
The document has been updated for the AM concept and the HLPLEX programming language.
2 APPLICATION
This document instruction applies to new descriptions of AXE (CNT, CNZ and CNA) blocks. When
descriptions are modified, the document should be adapted to the instruction as much as possible.
3 PURPOSE OF THIS DOCUMENT INSTRUCTION (DI)
This DI defines the structure and contents of a Block Description and gives instructions on how to
write a Block Description.
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 2 z 15
4 BLOCK DESCRIPTION (BD)
4.1 Purpose of a Block Description
The BD describes functionality within a block, which may cover one or more functions, or a part of a
function, and shows how these functions are distributed on the block (hardware and software) unit.
The external interfaces to other blocks and the internal interfaces between the block units are
described in a verbal and graphical manner. The BD also describes the dynamic behaviour of a
block, for example, in terms of event sequences. An event sequence has a defined start-point, which
is the event, followed by a sequence of actions that ends in a defined end-point.
4.2 Users of a Block Description
Those who need information and guidelines from the BD are:
Unit Designers, as a basis for unit design and basic test
Management, administration and customers as a product description
Function Designers and Block Designers as an aid to understand the block structure during
block update
4.3 Identification of a Block Description
The document head should contain the following information:
Document name:
The corresponding tag is called docname.
Enter the document name DESCRIPTION in capital letters.
Prepared:
The corresponding tag is called prep.
Enter your company code and office code, separated by a stroke (/), and your registered
initials.
Example: ETX/TX/DZ ADS
Subject responsible:
The corresponding tag is called subresp.
Enter the company code and office code, separated by a stroke (/), and the registered initials of
the person to be consulted.
Example: ETX/TX/DZ BKN
This field is entered only when:
A person other than the document's author is to be consulted on the contents of the
document
The office providing the data is not subordinate to the approving office
No.:
The corresponding tag is called docno.
Enter the document number, which must have the format:
1551- Uen
Example: 1551-CNT 216 1234 Uen
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 3 z 15
Doc respons/Approved:
The corresponding tag is called appr.
Enter a dash (-) here until the document has been approved.
The company code and office code of the Final Documentation Office is entered here. The
manager of this office signs the hard copy of the document, to indicate that it is a valid
document.
On the computer-stored document, the name is given within brackets to indicate that the
document has been signed.
Example: ETX/TX/FO (B. Eriksson)
Checked:
The corresponding tag is called checked.
Enter the company signature of the person who technically approves the document. He or she
signs the hard copy of the document.
The registered signature is entered here to indicate that the document has been signed.
Example: EEDUFR
Date:
The corresponding tag is called date.
Enter the date in the order YYYY-MM-DD
Example: 1994-06-21
The date on the document is the date when the document was last revised.
Rev:
The corresponding tag is called rev.
The revision letter defines the revision state of the document. Begin with A for a new
document. Use capital letters A ... Z, AA ... ZZ, except I, O, P, Q, R, U and W. A document
change which affects the subject contents, must be indicated by a stepped revision letter. Other
changes, such as correction of spelling errors etc., do not alter the revision letter.
Example: C is stepped to D, AB is stepped to AC.
A preliminary document is denoted by a "P" before the revision letter, and a numeral,
indicating the sequence number, after the revision letter. If a preliminary document must be
revised, the sequence number is stepped.
Example: PA1 is stepped to PA2.
When approved, the document gets a full-letter revision.
Example: PB4 becomes B.
Title:
The corresponding tag is called title.
Enter the title of the BD. Use capital letters.
BLOCK

Example:
BLOCK BASSC
DYNAMIC OUTGOING/INCOMING
B-CHANNEL ASSIGNMENT
4.4 Contents of a Block Description
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 4 z 15
All BDs should have a uniform structure and layout.
1 REVISION INFORMATION
2 GENERAL
3 IMPLEMENTATION
3.1 Block Structure
3.2 Data Structure
3.3 Program Structure
4 INTERWORK
4.1 External Interwork
4.2 Internal Interwork
4.3 Test Points and Operation Points
4.4 Commands
4.5 Printouts
5 FUNCTION
5.1 Object Classes
5.2 Start/Restart
5.3 File Size Alterations
5.4 Block Function
5.n Block Sub-Function n (if any)
5.n+1 Subroutines
6 REFERENCES
7 GLOSSARY (optional)
4.5 Writing a Block Description
This section explains how to write a BD. It defines the headings and numbering to be used. Under
each heading there is an explanation of what the specific heading should comprise. If a heading is
not applicable, then insert "-" under the heading.
To avoid duplication of information, give priority to flowcharts when describing program and data
structure. Use verbal description only if it helps understanding the flowchart.
4.5.1 1 REVISION INFORMATION
Give a brief description of the changes in the document if the revision is being stepped.
4.5.2 2 GENERAL
Give a short (3-6 lines) description of the main function(s) of the block.
4.5.3 3 IMPLEMENTATION
Implementation is divided into the following sections:
4.5.4 3.1 Block Structure
Give a brief description of the block's functional modules. Describe in which units (CP, RP, EMRP,
SP, and Hardware) the modules are implemented. If the block consists of more than one unit, then
draw a figure (block diagram) to show the units and their interfaces. For each unit briefly describe
the main purpose(s) of the unit. (Most blocks in AXE contain only one unit, that is, CP software.)
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 5 z 15
4.5.5 3.2 Data Structure
Briefly describe all the major data used in the block, specifying the block's common data, files, and
records. Describe data structures on external data media and in transferred buffers owned by the
block. Diagrams may be used in describing the data structure. For each Data Structure mentioned,
describe the main variables/individuals associated.
4.5.6 3.3 Program Structure
Describe how the code will be divided into different sub-programs (modules) within the block, when
implementing the block in PLEX. Give a brief description of each sub-program (module).
Describe how the block is divided into HLPLEX processes when implementing the block in
HLPLEX.
For a block containing Object Classes, describe each Object Class in a seperate sub-program (PLEX)
or process (HLPLEX).
For an SP block, show how each unit in the block is divided into Eripascal processes (SP) or
DEFAX modules. Give a description of the main functions for each process or DEFAX module.
4.5.7 4 INTERWORK
Interwork is divided into the following main sections:
External Interwork
Internal Interwork
Test Points and Operation Points
Commands
Printouts
4.5.7.1 4.1 External Interwork
External Interwork is divided into the following subchapters. If a subchapter does not contain
information then it should be ommitted:
4.1.1
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 6 z 15
PLEX External Interwork
4.1.2
HLPLEX External Interwork
4.1.3
Object Class Interface
4.1.4
Eripascal (SP) External Interwork
4.5.7.2 4.1.1 PLEX External Interwork
If the block is implemented in PLEX, the External Interwork with other blocks is implemented with
PLEX signals. The block can also use an Object Class Interface to communicate with other blocks.
See section Object Class Interface.
List all signals in the interface between the described block and other blocks. Indicate all software
signals, except those "hidden" in language statements (read/write signals), transited (a signal
received and then sent again by the same block) and "dummy" signals (signals specified in the Signal
Survey, but dummy marked in the code so that they will cause an exit from the code and not cause a
restart. These signals may then be used by the block in the future). Where blocks are linked together
to form a software relation, indicate only those transited signals which have a functional effect on the
block. Subdivide the signals into "received" and "sent" signals.
4.1.1.1 Received PLEX Signals
List the recieved signals in alphabetical order. For each received signal, give a short description (1-2
lines) of the signal function (as it is seen from this block). This should include the following
information:
Name of signal
Sender/Receiver
Purpose of signal
Example:Signal Name From Purpose
ASEIZE LI, IL, BL, SE Seizure of SEPRM individual. Originating call.
BANSWA LI, OL, BL, SE B subscriber answer.
4.1.1.2 Sent PLEX Signals
As specified for Received PLEX Signals.
Example:Signal Name To Purpose
CONTFSEND DAF Answer to question if the size alteration can take place.
DELSELINK LI, IL, OL, BL, SE Delete SEPRM link from SE chain.
4.5.7.3 4.1.2 HLPLEX External Interwork
If the block is implemented in HLPLEX, the External Interwork with other blocks is implemented
with HLPLEX Events, Procedures, Functions and Seizurecases. The block can also use an Object
Class Interface to communicate with other blocks. See section Object Class Interface. Describe the
HLPLEX Interwork between the described block and other blocks, under the following headings:
4.1.2.1 Received HLPLEX Events
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 7 z 15
List the received events in alphabetical order. For each received event, give a short description (1-2
lines) of the event function (as it is seen from this block).The events should be listed according to
their protocols. This should include the following information:
Protocol Name
Event Name
Sender
Purpose of event
Example:Protocol Name Event Name From Purpose
ATCA_ATJA ATTNEWDESTINFO ATCA Call diversion information
ATTL_ATJA SERIALCALLINFO ATTL Mark call for Serial Call
4.1.2.2 Sent HLPLEX Events
As specified for Received HLPLEX Events.
Example:Protocol
Event Name To Purpose
Name
Inform that status of the subscriber has been
ATCC_ATJC CHSUBSTATEINFO ATTL
changed.
ATTB_ATJB ATTSTARTINGREQ ATCA Asks ringing to be stated.
4.1.2.3 HLPLEX Procedures
List the HLPLEX Procedure names, the block owner and the purpose of the HLPLEX Procedure in
following format:
Procedure Module Owner Purpose
- - -
- - -
4.1.2.4 HLPLEX Functions
List the HLPLEX Function names, the block owner and the purpose of the HLPLEX Function in
following format:
Function Module Owner Purpose
- - -
- - -
4.1.2.5 HLPLEX Seizurecases
List the HLPLEX Seizurecase names, the block owner and the purpose of the HLPLEX Seizurecase
in following format:
Seizurecase Module Owner Purpose
- - -
- - -
4.5.7.4 4.1.3 Object Class Interface
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 8 z 15
Note: This section is applicable to both HLPLEX and PLEX.
There are two types of blocks that use an Object Class Interface:
Blocks containing Management Function (MF) functionality
Object Owning Blocks
When an MF wants to communicate with an Object Class and vice versa, they must use the interface
(messages) described in the Object Class Description (OCD). The MF and Object Class use this
interface differently (see ).
Management Function
A Management Function only has to implement those parts (messages) of an OCD that it requires to
fulfill it's functionality. If this Block Description is for a block acting as a Management Function,
include the following information:
4.1.3.1 Messages sent by Management Function to Object Class
List the messages the MF can send in alphabetical order. For each message specified, give a short
description (1-2 lines) of the message function (as it is seen from this block). This should include the
following information:
Message Name
NOTE: It is possible that message names can be the same in different Object Class Protocols,
so specify the message name in the format where OC is the name of the Object Class
that defines the message and M is the message name,
Names of Object Classes that the MF may send the message to,
Purpose of message.
Example:Messages Object Classes Purpose
PROPHAN, This message implements the sending of the
TOP.close_association_c
SUBSCR, BSHAN actionclose_association on C-level.
PROPHAN, Up to 16 instances of the subsription object
SUBCHECK.check
SUBSCR can be checked with this message.
This message implements the sending of the
PRVCHAR.get_restr_type_of_snb BSHAN
action get_RestrTypeOfSNB .
For each Object Class listed, refer to it's Object Class Description in Chapter 6, References.
4.1.3.2 Messages Received by Management Function from Object Class
As specified for Messages Sent by MF to Object Class in previous section.
Example:Messages Object Classes Purpose
PROPHAN, This message is a reply to the check
SUBCHECK.check_resp
SUBSCR message.
This message is sent in response to the
PRVCHAR.get_restr_type_of_snb_ack BSHAN
message get_restr_type_of_snb .
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 9 z 15
For each Object Class listed, refer to it's Object Class Description in Chapter 6, References.
4.1.3.3 Event Notifications received by Management Function
For each Event Notification that can be received by the MF, list the name of the Events in
alphabetical order and it's Purpose in the following format:
Example:Event Name Purpose
Pbx_subscr_admin This event occurs after linking or unlinking of a GIN.
Object Owning Block
A Block containing an Object Class must implement all messages that can be received by the Object
Class. If this Block Description is for an Object Owning Block, include the following information
for each Object Class that the block owns:
4.1.3.4 Object Classes owned by the Block
List the Object Classes that the Block owns in alphabetical order, and include the following
information:
Object Class Name
Purpose of Object Class
Example:Object
Purpose
Class
Defines the structure and the means of obtaining Call Path Tracing Information
CAPTAM
in an AM based system.
Reads subscriber numbers from the IO Buffer for translation in addition to the
TRANSNB
insertion of translated subscriber numbers into the IO Buffer.
Information on the messages that the Object Class can receive and send can be found in the OCD for
the Object Class. For each Object Class listed, refer to it's OCD in Chapter 6, References.
4.5.7.5 4.1.4 Eripascal (SP) External Interwork
If the block is implemented in Eripascal (SP Design only), describe the Interwork between the
described block and other blocks, under the following headings:
4.1.4.1 Received Signals
List the recieved signals in alphabetical order. For each received signal, give a short description (1-2
lines) of the signal function (as it is seen from this block). This should include the following
information:
Name of signal
Sender/Receiver
Purpose of signal
Example:Signal Name From Purpose
ASEIZE LI, IL, BL, SE Seizure of SEPRM individual. Originating call.
BANSWA LI, OL, BL, SE B subscriber answer.
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 10 z 15
4.1.4.2 Sent Signals
As specified for Received Signals.
Example:Signal Name To Purpose
CONTFSEND DAF Answer to question if the size alteration can take place.
DELSELINK LI, IL, OL, BL, SE Delete SEPRM link from SE chain.
4.1.4.3 Procedures and Functions
Show all imported subroutines (procedures and functions) for the SP block. In addition, list any
exported subroutines, besides those described in the open interface documents. List the subroutines
alphabetically and subdivide into the following headings:
ImportedProcedure/Function Exporter Purpose
- - -
- - -
ExportedProcedure/Function Purpose
- -
- -
4.1.4.4 Types
Show all Eripascal types imported by the block, and from where they are imported. In addition, list
any exported types, besides those described in open interface documents.
ImportedName Exporter Purpose
- - -
- - -
ExportedName Purpose
- -
- -
4.1.4.5 Constants
Show all Eripascal constants imported by the block, and where they are imported from. In addition,
list any exported constants, besides those described in the open interface documents. Use the same
headings as for exported types (see previous section).
4.5.7.6 4.2 Internal Interwork
Internal Interwork is divided into the following subchapters. If a subchapter does not contain
information, it should be ommitted:
4.2.1
PLEX Internal Interwork
4.2.2
HLPLEX Internal Interwork
4.2.3
Eripascal (SP) Internal Interwork
4.5.7.7 4.2.1 PLEX Internal Interwork
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 11 z 15
List all signals sent between the central and the regional Software Units and signals sent to own
Software Unit (not LOCAL). If a regional Software Unit exists, subdivide the chapter into "CP -
RP", "RP - CP" and "CP - CP" and list the signals in alphabetical order. For each signal, give a short
(1-2 lines) description of the signal function.
Also list the local signals of the block.
4.2.1.1 CP - RP Signals
List the CP - RP signals alphabetically. For each CP - RP signal, give a short (1-2 lines) description
of the signal function. Divide in incoming and outgoing signals.
4.2.1.2 RP - RP Signals
As for CP - RP signals, 4.2.1.1
4.2.1.3 CP - CP Signals
As for CP - RP signals, 4.2.1.1
4.2.1.4 SP - SP Signals
For SP blocks that interwork with other SP blocks, list, in alphabetical order, the signals used in the
interwork.
List also the Local signals of the block.
4.5.7.8 4.2.2 HLPLEX Internal Interwork
4.2.2.1 HLPLEX Block Internal Events
List all HLPLEX events between two processes within the block and give a short description (1-2
lines) of each event.
4.5.7.9 4.2.3 Eripascal (SP) Internal Interwork
4.2.3.1 Procedures and Functions (SP onlly)
Show any module level subroutines (procedures and functions) for an SP block. List the subroutines
alphabetically subdivide into the following headings:
Procedure/Function Purpose
- -
- -
4.5.7.10 4.3 Test Points and Operation Points
This section applies only to blocks that have associated hardware. List the different points. Give a
short description of the message which can be sent or received for each point.
4.5.7.11 4.4 Commands
List the commands which can be received by the module. Give a short description of the command
function for each command code.
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 12 z 15
4.5.7.12 4.5 Printouts
List the printouts which can be initiated by the module (not procedure printouts). Give a short
description of the printout.
4.5.8 5 FUNCTION
4.5.8.1 5.1 Object Classes
Specify all Object classes which the block owns.
4.5.8.2 5.2 Start/Restart
Describe all Start/Restart phases in which the block participates as well as the initializations made.
4.5.8.3 5.3 File Size Alterations
Describe, where applicable, the following Size Alterable entities:
Files,
HLPLEX Procedures,
HLPLEX Functions,
HLPLEX Processes.
.
4.5.8.4 5.4 Block Function
Give a graphical description of the block functions. Give a brief verbal description of each module.
Divide the chapter into subchapters, one subchapter for each block subfunction. Describe the block
function with all its normal and abnormal cases of events. If the abnormal cases are not complex,
they may be described with the normal cases.
External interwork (an interwork with a block outside the block in question) may be shown in either
of the ways outlined below. When naming external blocks, use the Free Text symbol followed by the
name of the block to indicate the external block name. This symbol will not appear in the printout.
The signal name should be given above the signal line.
Pseudo-code is recommended to describe SP-block functions instead of flowcharts.
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 13 z 15
The external blocks do not have to be shown in a separate column. The signal name is given beside
the signal, and the name of the block from which the signal is sent or received is written below the
signal using the Free Text symbol.
4.5.8.5 5.n Block Sub-Function n (if any)
Clearly describe together with a flowchart the course of events for all block subfunctions. The
description should show when a specific signal is sent or received and how this signal is related to
other signals. When the external interwork is described, interworking blocks or subsystems may be
indicated by their designations. If there are no block subfunctions to describe, omit this chapter.
4.5.8.6 5.n+1 Subroutines
Give a verbal and graphical description in alphabetical order of the subroutines of the block.
4.5.9 6 REFERENCES
List references made to other documents.
List also Function DescriptionsFDs, Interwork DescriptionsIWDs (SP design only), and Design
RulesDR that are applicable for the function block.
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 14 z 15
Structure the list as you find appropriate, for example as below:
Document References
[1]
1551-CNT 216 1610 Uen, BLOCK CAPP
Function Description
1/155 16-CNT 216 1611 Uen
CALL PATH TRACING
Control System Design Rules
ETX 102 60-1026
Execution Time Limits
ETX 102 60-1207
Limitations in Signal/Event sending
ETX 102 60-1141
Command Routines in AXE
ETX 102 60-1114
System Start and Restart in AXE
ETX 102 60-1116
Selection of Signalling Level
XT/UD 81 022
Standardized Signals for Level Change
General Application Design Rules
X/UD 26 78 Ue
Global States in APT 210; Definitions
Function Specific Design Rules
X/U 159-75 104 Ue
Tracing of Switching Paths
4.5.10 7 GLOSSARY (optional)
5 GLOSSARY
BD
Block Description
Block Units
The function block could be split into 1 CP unit and 1 EMRP unit, or 2 CP units and 1 RP unit,
etc.
CP
Central Processor
DEFAX
Definition Module in AXE
Dummy signal
A dummy signal is specified in the Signal Survey, but dummy marked in the code so that it
will cause an exit from the code and not cause a restart. This type of signal may be used by the
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30
BLOCK DESCRIPTION Strona 15 z 15
block in the future.
EMRP
Extension Module RP
Functional Modules
A functional module is a part of the block in which a particular function is implemented.
HLPLEX
High Level PLEX
MF
Management Function
OCD
Object Class Description
RP
Regional Processor
SP
Support Processor
6 REFERENCES

AM Encyclopedia
EN/LZT 101 1859

Design Directive for MF's and OOB's
EEI/STB-94:0213 Uen
file://C:\Documents%20and%20Settings\wakr\Pulpit\wiedza\tomax\mdoc-309.html 2004-12-30


Wyszukiwarka

Podobne podstrony:
Test di controllo
GiorgioGaber Io non mi sento italiano di AnnaToscano Il discorso indiretto
Francesco d’Assisi Cantico di Frate Sole
Ferzan Ozpetek Finestra di fronte, La (2003)
EXT2 SUPER BLOCK (2)
Source Parametre List DI
01 140 Read measure value block 08
testo di storia
motore di Stirling
W220 Block Diagram signal

więcej podobnych podstron