Wpływ układu pracy na moc odbiornika trójfazowego
U12 |
U23 |
U31 |
I1 |
I2 |
I3 |
IU |
IV |
IW |
P1 |
P2 |
P |
P/P1 |
P/P1 |
V |
V |
V |
A |
A |
A |
A |
A |
A |
W |
W |
W |
----- |
------ |
77 |
80 |
80 |
0,96 |
0,91 |
0,96 |
0,52 |
0,53 |
0,55 |
68 |
60 |
128 |
1,88 |
1,87 |
78 |
80 |
82 |
0 |
0,80 |
0,80 |
0,26 |
0,53 |
0,26 |
0 |
59 |
59 |
0 |
0 |
77 |
80 |
80 |
0,52 |
0,90 |
0,53 |
0,52 |
0,53 |
0 |
23 |
59 |
82 |
3,56 |
5,53 |
78 |
80 |
82 |
0 |
0,52 |
0,53 |
0 |
0,53 |
0 |
0 |
41 |
41 |
0 |
0 |
U12 |
U23 |
U31 |
I1 |
I2 |
I3 |
IN |
U1 |
U2 |
U3 |
P1 |
P2 |
P3 |
P |
P/P1 |
P/P1 |
V |
V |
V |
A |
A |
A |
A |
V |
V |
V |
W |
W |
W |
W |
----- |
----- |
76 |
80 |
77 |
0,31 |
0,29 |
0,28 |
0 |
42 |
38 |
44 |
13 |
13 |
15 |
41 |
3,15 |
2,06 |
77 |
80 |
80 |
0 |
0,30 |
0,30 |
0,31 |
0 |
36 |
44 |
0 |
13 |
15 |
28 |
0 |
0 |
76 |
80 |
79 |
0,26 |
0,26 |
0 |
0 |
35 |
36 |
0 |
9 |
10 |
0 |
9 |
1,0 |
3,64 |
76 |
80 |
78 |
0,30 |
0 |
0 |
0,30 |
41 |
0 |
0 |
13 |
0 |
0 |
13 |
1,0 |
3,20 |
Obliczenia:
P = P1 + P2 = 68 W + 60 W = 128 W; P = P1 + P2 + P3 = 13W + 13W + 15W = 41W
P / P1 = 128 W / 68 W = 1,88 ( obliczeniowe )
Trójkąt:
Ip = √3 If ; Iv = Iu = Iw = If = 0,53 A
P = 3 Uf If ; U12 = U23 = U31 = Uf = 80 V
P = 3 ⋅ 80 V ⋅ 0,53 A = 127,2 W
P/ P1 = 127,2 W / 68 W = 1,87 ( teoretyczne )
Gwiazda:
Uf = Up / √3 = 80 V /√3 = 46,24 V
P = 3 Uf If = 3 ⋅ 46,24 V ⋅ 0,29 A = 26,82 W
P / P1 = 26,82 W / 13 W = 2,06
Odbiornik gwiazdowy niesymetryczny:
Przypadek |
U12 |
U23 |
U31 |
I1 |
I2 |
I3 |
IN |
U1 |
U2 |
U3 |
P1 |
P2 |
P3 |
P |
|
V |
V |
V |
A |
A |
A |
A |
V |
V |
V |
W |
W |
W |
W |
1 |
98 |
100 |
97 |
0,58 |
0,34 |
0,32 |
0,24 |
52 |
52 |
55 |
33 |
19 |
21 |
73 |
2 |
98 |
100 |
95 |
0,48 |
0,38 |
0,40 |
0 |
42 |
55 |
58 |
22 |
23 |
25 |
70 |
3 |
98 |
100 |
98 |
0,38 |
0,34 |
0 |
0 |
33 |
60 |
0 |
13 |
22 |
1 |
36 |
Obliczenia:
P = P1 + P2 + P3 = 33 W + 19 W + 21 W = 73 W ( przypadek 1 )
+
3 ) Wykaz przyrządów pomiarowych:
Rezystory: R = 177 Ω I = 0,6 A E2/P3/203
R = 183 Ω I = 0,6 A E2/P3/125
R = 179 Ω I = 0,6 A E2/P3/135
Watomierz: FM; kl. Dokładnosci 0,5 E2/P3/262
zakr. napięciowy: 100 / 200 /400 V
zakr. prądowy: 0,5 / 1 A
Watomierz: FM; kl.dokładnosci 0,5 E2/P3/263
zakr. napięciowy : 100 / 200 / 400 V
zakr. prądowy : 0,5 / 1 A
Transformator: E2/P3/304
P = 3 x 1000 VA
f = 50 ÷ 60 Hz Tip: 3
Imax = 4,6 A Ubl: 3 x 380 V
Tablica laboratoryjna w sali laboratoryjnej ( scienna ):
woltomierze
watomierze
amperomierze