26 marzec 2006 Albercik
SAFETY EQUIPMENT
=================
RULES AND REGULATIONS
----------------------------------------
1.1 Pyt. Can National Maritime Authorities and Classification Societles require additions to the SOLAS
requirements?
C Odp. Yes.
1.2 Pyt. Who must be familiar with the Musterlist and Emergency Instructions on board?
C Odp. All crew members and other personnel on board.
1.3 Pyt. Does the Musterlist and Emergency Instructions contain information relevant only to the deck
officers?
C Odp. No,all crew members and other personel on board.
EXTINGUISHING AGENTS AND FIRE CLASSES
-------------------------------------------------------------------
2.1 Pyt. Trzeba zaznaczyc jakie oznaczenia sa do ktorej ikonki.
Odp. A
B
C
-
2.2 Pyt. Which of these extinguishing agents deprive the air of oxygen and therefore may causa
suffocation in a confined space?
A Odp. CO2.
2.3 Pyt. A fire has broken out in your cabin (the bunk),which of the extinguisher agents listed below are
best suited to extinguish the fire?
A Odp. Water.
2.4 Pyt. A short circuit causes fire in the electrical system,which extinguishing agent must not be used
to extinguich the fire?
B Odp. Water.
2.5 Pyt. A frying pan catches fire in the galley,which extinguishing agents shall you use?
B Odp. CO2 or Powder(type BC)
FIRE FIGHTING APPLIANCES
------------------------------------------
Trzeba zaznaczyc aby dalej przrjsc ! Fire fihgting appliances on bard are defined as: (Pytanie nie
punktowane, bierzemy 1 test gorny a potem dolny)_
3.1.1 Pyt. A CO2 system extinguishes a fire In a protected space by
C Odp. Depriving the fire of oxygen.
3.1.2 Pyt. Is this statement true or false?
“Always attempt to extinguish a fire before sounding the alarm”
A Odp. False.
3.1.3 Pyt. The general alarm sounded by the detection system can be described as:
A Odp. 7 short blast and 1 long blast.
3.1.4 Pyt. A sprinkler system is normally used to protect the.....
b Odp. Accomodation area
3.1.5 Pyt. .................. is listed as a CFC gas,as of January 1 st 1994 ................. systems are not
installed on board new ships.
B Odp. Halon
3.2.1 Pyt. Uzupelnic literowe oznaczenia gasnic.
Odp. Foam AB Accomodation areas and Engine room
Water A Accomodation area
Dry powder ABC Accomodation areas and Engine room
CO2 BC Radio room,galley,Engine Control Room,is used in Pump room
3.2.2 Pyt. Where do you always find operation and maintenance instructions for the extinguishers?
B Odp. On the label of the extinguisher.
3.2.3 Pyt. The firehose cabinets shall contain:
Odp. Skrzynka,waz,pradownica.
3.2.4 Pyt. The firemans Outfit is required on board all ships under SOLAS and shall contain:
Odp. Srebny kombinezon,butla tlenowa,toporek,latarka.
3.2.5 Pyt. Emergency compressed air breathing escape sets on bard chemical and gas carries stall
have duration of service not less than
B Odp. 15 minutes.
3.2.6 Pyt. According to SOLAS the breathing air apparatus that must be on board shall have
sufficient capacity for how many minutes of operation?
B Odp. 30 minutes
LIFE SAVING APPLIANCES
---------------------------------------
4.1 Pyt. Instructions for how to operate and release a life raft you will find on the
B Odp. Container where the raft is stored
4.2 Pyt. Uzupelnij
Odp. 1. free fall boat
2. davit launched
3. man overboard boat
4.3 Pyt. Uzupelnic.
Odp. Zielona antena sat. z strzałkami zialonae radio wieksze zielone rodio mniejsze
Jakby czerwona gasnica radiotelefon bialo nieb.jakby gasnica
4.4 Pyt. Uzupełnić.
Odp. 1. life jackets
2. embarkation stations
3. lifebuys
4. open deck