TABELARYCZNE ZESTAWIENIE OBLICZEŃ DO PRZEPŁYWU CIEPŁĄ I DYFUZJI PARY WODNEJ PRZEZ ŚCIANĘ TRÓJWARSTWOWĄ.
numer: 33 ti=15+0,1⋅33=18,3 °C; te=0-0,1⋅33= -3,3 °C
ϕi=30+33=63 %; ϕe=60+33/2=76,5 %
ps(18,3° C)=21,05 [hPa] =2105 [Pa]; ps(-3,3 °C)=4,64 [hPa] =464 [Pa]
pi=ϕi⋅ ps(18,3° C)/100=63⋅2105/100=1326,2 [Pa]; pe=ϕe⋅ ps(-3,3° C)/100=76,5⋅464/100=355 [Pa];
Warstwa |
Grubość d [m] |
λ [W/m⋅K] |
δ [g/m⋅h⋅Pa] |
R (d/λ) [m2⋅K/W] |
r (d/δ) [m2⋅h⋅Pa/g] |
Δt [°C] |
ΔP [Pa] |
t [°C] |
P [Pa] |
Ps (t) [Pa] |
Powietrze wewnętrzne |
|
|
|
0,120 |
|
0,71 |
|
18,30 |
1326,2 |
2105 |
|
|
|
|
|
|
|
|
17,59 |
1326,2 |
2014 |
Tynk wapienny |
0,015 |
0,70 |
0,000075 |
0,021 |
200 |
0,12 |
16,5 |
|
|
|
|
|
|
|
|
|
|
|
17,47 |
1309,7 |
2001 |
Mur z pustaka MAX |
0,29 |
0,40 |
0,000135 |
0,723 |
2140,7 |
4,27 |
176,5 |
|
|
|
|
|
|
|
|
|
|
|
13,20 |
1133,2 |
1518 |
Styropian |
0,10 |
0,04 |
0,000012 |
2,500 |
8333,3 |
14,76 |
687,2 |
|
|
|
|
|
|
|
|
|
|
|
-1,56 |
446,0 |
534 |
Warstwa osłonowa z pustaka MAX |
0,09 |
0,40 |
0,000135 |
0,223 |
659,3 |
1,32 |
54,4 |
|
|
|
|
|
|
|
|
|
|
|
-2,88 |
391,6 |
480 |
Tynk cementowo - wapienny |
0,02 |
0,90 |
0,000045 |
0,022 |
444,4 |
0,13 |
36,6 |
|
|
|
|
|
|
|
|
|
|
|
-3,01 |
355,0 |
476 |
Powietrze zewnętrzne |
|
|
|
0,050 |
|
0,30 |
|
|
|
|
|
|
|
|
|
|
|
|
-3,31 |
355,0 |
464 |
|
|
|
Σ |
3,659 |
11777,7 |
21,61 |
|
|
|
|
|
|
Katedra Budownictwa Wiejskiego Akademia Rolnicza w Krakowie |
Kraków 22.03.2001 |
Ćwiczenie 1
Projektowanie ściany zewnętrznej budynku.
Rok akademicki: 2000/2001 Rok studiów: IV |
Kowalska Monika Wydział Inżynierii Środowiska i Geodezji |