No.    1000-00104

Framo Submerged Cargo    Pumps    oate/sign:    ujan77/

PURGINGINSTRUCTION    £*9*    5ofs

Rev. I:    08Jun04/AGAa

4 TROUBLE SHOOTING

Warning: To preveni damage from hazardous cargoes, take necessary precauttons, wear safeły gear and avoid contact with spray/gases.

Symptom:

POSSIBLE REASON:

Remedy: *)

Not possible to purge the cofferdam (no air. inert gas or liquid coming out of the check pipę when purging)

(See also chapter 1)

a)    No or insufficient purging medium supply

b)    Blocked cofferdam system

Notę!

fn case steam is used in attempt to elear a blockage in pamp cofferdam system pay special allention not to over pressarize the pamp/pipę stack

a)    Check valves. hose connections and purging medium relief valve (open at approx. 3 bar).

b)    Check the exhaust trap and the piping on deck for blockage. Open if possible.

b1) Disconnect check pipę from pump unit (Icrwer seal house) - watch oat for possible pressurized lrqaid rn cofferdamli By carefully purging check if the blockage is located in the check pipę or in the pump/ pipę stack cofferdam Depending on the naturę of the medium blockmg the cofferdam system use steam or solvent to dissolve the blockage.

Dismantling of pump might be required.

Notę! Pressare test pamp after assembly

Cargo leakage to pump cofferdam.

(See also chapter 1)

General

Notę!

Afways pressare test pamp prror to and after dismantling. This is regaired to locate possible leakage and to confirm no leakage apon completion of repair.

Pressure test pump cofferdam system at approx 3 bar.

Check for leakage - if required spray with soapy water to locate the leakage

a) Worn cargo seal Notę; If no leakage is detected by pressure test it islikely that the cargo leakage to cofferdam is caused by worn cargo seal. (the upper seal lip is sealing when pressurizing cofferdam).

a) Replace cargo seal set.

AJso. carefully check ceramic sleeve for possible damage-wear

b) Leaking seal element in flange connection

b) Check for loose bolts and for pitting corrosion in seal faces - in case of corrosion repair is required

When assemble.renewdamaged seal element.

c) Crack/pinhole in piping

c) Contact a Framo Service Station.

*) Ref inslruction for maintenance and repair for actual pump


Wyszukiwarka

Podobne podstrony:
5instructions640 No.    1000-00104Framo Submerged Cargo
7instructions640 No.    1000-00104Framo Submerged Cargo
6instructions640 FRAMO No.    1000-00104Framo Submerged Cargo Pumps Date/sign: i4jan7
7instructions640 No.    1000-00104Framo Submerged Cargo
3instructions640 No.    10004)0104Framo Submerged Cargo Pumps Date/sign: ujan77/
4instructions640 No.    10004)0104Framo Submerged Cargo
4instructions640 No.    10004)0104Framo Submerged Cargo
3instructions640 No.    10004)0104Framo Submerged Cargo Pumps Date/sign: ujan77/
8instructions640 PURGING ROUTINE FOR FRAMO SUBMERGED CARGO PUMPSO)m x SHIPNAME VOYAGE NO
Obraz1 (69) no* 1000 + 2000 ~B~ p ’ nc - 1000 ^ 2000 237,8 239,9 Przyjmuję długość pasa równą 2
200 400 600 800 1000 T2mr^ Machinę: Linear Example Serial No:15345/Lin Date:08:09 May 16
Comparison of no. of infections per 1000 inhabitants in 4 countries nearthe same latitude and using
No. of cases per 1000 inhabitants (Daily data El Pais 13.4.20) ITALY 2.59 SAN
Correlation of no. of infections per 1000 inhabitants with 5G KoŁpit_ de UoDregai de Uamanet 1,3 SAN
Przewody hamulcowe 1 99562-1000 99562-1000- (Ć)
1l (INTCOM) i 78 mVp-p(INT COM) - 1000 mVp-p (SP-PMONE) 10 mVp p 01 rr FINAŁ POWER AMP 15 mVp-

więcej podobnych podstron