With new advancements in Mechanical CPR, Michigan Instruments ended production of the Thumper® 1007* model in 2007 and introduced the 1007CC and 1007CCV models.
In 2003, the Life-Stat™ Model 1003 was developed in compliance with 2005 AHA Guide linę s. Due to the success of the Life-Stat™ Model 1003 Mechanical CPRdevice, Michigan Instruments will officially end production of the Model 1007CCV on December 31, 2009.*
Michigan Instruments is pleased to offer an UPGRADE PROGRAM for the current owners ofthe Model 1007 or Model 1007CCV Thumper® CPR.
For morę information about this special program, contact us for upgrade pricing on either model. We will be morę than happy to provide you with a ąuote.
Optionally, you may consider a trade-in of your Model 1007 or 1007CCV Thumper® towardsthe purchase of a NEW Model 1003 Life-Stat™.
*Service and technical support for Thumper® 1007 and 1007CCV will continue to be provided.
The Life-Stat™ Model 1003 provides complete,
Hands-Free CPR. per 2005 AHA Guide linę s for both Basic Life Support (BLS) and Advanced Life Please click link for morę dstails.
Support (ALS) protocols.
Electronic System
Control Panel
• Switchfrom30:2 (BLS) to CCV modę (ALS) seamlessly
• Pause/Resume CPR
• U ses long-life 9 voŁ battery supply
• Batteries canbe “hot swapped’ outwhile unit is tunmng
Patient Retention System (PRS)BackBoard included Works on large rangę of patient
sizes, including bariatric patients.
DISTRIBUTORS AND REPRESENTATIVES
Where we’ll be:
OCT 26-30. 2009 ATLANTA. GA
A NEW WAY 0F THINKING
55th AARC INTERNATIONAL RESPIRATORY CONGRESS
DEC 5-8.2009 SAN ANTONIO. TX
► Click here for supporting 3nd 3ddition3l information Reouest Price Ouote
The Thumper Model 1007CCV has many advantages over the use of standard chest compressions, including:
• Continuous CPR
• 100 Compressions/ Min
• 50% Duty Cycle
• Ventilation
-Time Cycled. const3ntflovvventil3tor -Adjusted Volume Control: 400-1200ml
• Light- Only 20lbs
• FastDeployment
• No Loss of CPR during Deployment
• No rescuerfatigue
• Allows 3mbul3nce personnel to be in safety belts during transport 3nd free to provide C3re to the patient