{\rtf1\ansi\deff0{\fonttbl{\f0\fnil MS Sans Serif;}}
{\colortbl ;\red255\green0\blue0;\red0\green0\blue0;}
\viewkind4\uc1\pard\qc\cf1\lang2057\b\f0\fs24 G96 Constant Surface Speed Control
\par \cf2\b0\fs20
\par \pard\cf1\b\fs24
\par \cf2\b0\fs20 If surface speed (relative speed between tool and billet) is set after the address S __ , the spindle speed is calculated so that the surface speed is always the specified value in relation to the tool position.
\par The units used will depend on whether the machine is operating using metric or imperial measurements.
\par
\par The units of surface speed are as follows:
\par
\par Input Unit. Surface Speed Unit.
\par Metric - Millimetre. Metres per Minute, M/Min.
\par Imperial - Inches. Feet per Minute, Feet/Min.
\par
\par A G96 command for surface speed control is written in the following format:
\par G96 S __ ;
\par where,
\par S __ is the surface speed (M/Min or Feet/Min)\cf1\b\fs24
\par
\par
\par
\par
\par
\par }