0 sclabs"
Tested by high-performance liquid chroma-tography with diode-array detection (HPLC-DAD). |
COMPOUND |
LOD/LOO (mg/g) |
MEASUREMENT UNCERTAINTY (mg/g) |
RESULT (mg/g) |
RESULT <%) |
CBD |
0.004 / 0.011 |
*0.0201 |
0.420 |
0.0420 | |
Mathod: OSP • (11S7) o! Carnab<iKi<£< by WtC-OAO |
CBG |
0.002/0.005 |
*0.0011 |
0.017 |
0.0017 |
CBN |
0.001/0.004 |
*0.0003 |
0.007 |
0.0007 | |
TOTAL THC: Not Dctccted |
A9THC |
0.002/0.005 |
N/A |
ND |
ND |
Total THC (A9THC+0.877*THCa) |
A8THC |
0.01/0.02 |
N/A |
ND |
ND |
TOTAL CBD: 190.260 mg/unit Total CBD (CBD*0.877*CBDa) |
TH Ca |
0.001/0.002 |
N/A |
ND |
ND |
THCV |
0.002/ 0.008 |
N/A |
ND |
ND | |
THCVa |
0.002/0.005 |
N/A |
ND |
ND | |
TOTAL CANNABINOIDS: 201.132 mg/unit |
CBDa |
0.001/0.003 |
N/A |
ND |
ND |
Total Cannabinoids (Total THC) + (Total CBD) + (Total CBG) ♦ (Total THCV) + (Total CBC) ♦ |
CBDV |
0.002/0.007 |
N/A |
ND |
ND |
(Total CBDV) + A8THC + C8L + CBN |
CBDVa |
0.001/0.003 |
N/A |
ND |
ND |
CBGa |
0.002 / 0.006 |
N/A |
ND |
ND | |
C8L |
0.003 / 0.008 |
N/A |
ND |
ND | |
TOTAL CBG: 7.701 mg/unit |
CBC |
0.003 / 0.010 |
N/A |
ND |
ND |
Total CBG (CBG*0.877’CBGa) |
CBCa |
0.001/0.004 |
N/A |
ND |
ND |
TOTAL THCV: ND |
SUM OF CANNABINOIDS |
0.444 mg/g |
0.0444% |
Total THCV (THCV+0.877*THCVa)
A9THC per UnH |
1100 per-package limit |
ND |
PASS |
Total THC per Unit |
ND | ||
CBD per Unit |
190.260 mg/unit | ||
Total CBD per Unit |
190.260 mg/unit | ||
Sum of Cannabinoids per Unit |
201.132 mg/unit | ||
Total Cannabinoids per Unit |
201.132 mg/unit | ||
MOISTURE TEST RESULT |
DENSITY TEST RESULT |
VISCOSITY TEST RESULT | |
Not Tested |
Not Tested |
Not Tested |
SC Laboratories. LLC100 Pioneer Street. Suitę E. Santa Cruz. CA 95060 I 866-43S-0709 I sclabs.com | C8-O0OCO13-UC IISO/1ES17025 :2017 Accrcd.ted PJLA Accrcditation Number 87168 4' 2020 SC Labs ai rights rese^yed. Trademarks refereneed aro trademarics of either SC Labs or ther resocctive owners. MKT0003 REVS 6/20 CoA ID: 200922R012-CO! Page 2 of 6