Subdomain Settings - Convection and Conduction (cc)
Equation
ójsP^aT/et + V-(-kVT) = Q - pCpu-VT T = temperatura
Subdomains
Groups
Subdomain selection
> | ||
■r- | ||
Group: |
▼ | |
Select by group | ||
V; Active in this domain |
Quantity
6.
Physics Init [ ElementT
Thermal properties and heat sources/sinks
Library materiał: High-strength alloy steel ▼
ts
o k(isotropic) 44.5[W/(m*K)]
I
Load...
Unit |
Description |
1 |
Time-scaling coefficient |
W/(m-K) |
Thermal conductivity |
W/(m-K) |
Thermal conductivity |
kg/m3 |
Density |
J/(kg-K) |
Heat capacity at constant pressure |
1 |
Ratio of specific heats |
W/m3 |
Heat source |
m/s |
Velocity field |
Artificial Diffusion...
OK
Cancel
Apply