A A 098


GRAM-AA- 98
PARTS-SERVICE
June 20 1998
Models:
S&H 70-155XL
GRAM
S&H 45-65 XM
SUBJECT: SETTING INITlAL IGNITION TIMING ON 1996 AND LATER 3.0&4.3 LITER G.M.
ENGINES
Current procedures for setting initial ignition timing on 1996 and later 3.0 and 4.3 liter G.M. engines as
outlined in the Service Repair Manual and Dealer Letters has proven to be insufficient in some cases.
Because of this Service Engineering is recommending that ONLY the Rinda timing adapter be used to set, or
check ignition timing on 3.0 and 4.3 liter G.M. engines that are built from 1996 thru 1998 as of this writing.
Instructions are included with the timing adapter. To order the RINDA TIMING ADAPTER P/N 95009:
RINDA TECHNOLOGIES
4563 North Eleston Avenue
Chicago, Illinois 60630
Tel: (773) 736 6633
Fax: (773) 736 2950
INSTRUCTIONS FOR USE OF THE RINDA TIMING ADAPTER
1. Unplug the four-wire connector on the distributor housing.
2. Plug the timing adapter into the distributor housing where you removed the four-wire
connector.
3. Plug the four-wire connector into the timing adapter.
4. Attach the alligator clip, located on the timing adapter s red wire to battery positive.
5. Start the engine and set the base timing to  0 degrees BTDC for the 4.3L engine and ( 8
degrees for the 3.0L engine) at idle.
6. Remove the timing adapter harness after engine shutdown and reconnect the original
four-wire connector to the distributor.
Timing is now complete.
NOTE; Disconnecting the initial timing connector jumper wire and R.P.M. at 1200 is not
required for this procedure.
PARTS STOCK: N/A
EFFECTIVE S/N: By engine build code. 3.0 liter 5RA or 5RS
4.3 liter 6LX
We reserve the right to make changes in design or add improvements without incurring the obligation to make such
changes in equipment previously manufactured.


Wyszukiwarka

Podobne podstrony:
098 103 tb4ari2cfxy6bndjlnlwyasohxtdqgwgcepy5ja
098 ADMM
095 098
095 098 r6zasmwfalugjlutqwlhyvwea6w3ebelfalbo7y
096 098
095 098
098 99
095 098 fwd4ngz32i2e675g3zotm6opg2a5rl62sfmo5fi
2010 Wykład 12 Pierwiastki d, f elektronoweid 098
v 04 098
098 102
098 100
098 Ustawa o op atach abonamentowych

więcej podobnych podstron