Daily Operating Instructions for JOWA OWS
Before Start, ensure the user is authorised to operate the equipment.
To Start Operation
1. Check Valves on Inlet Pipe.
2. Check Valves on Outlet Pipe.
3. Check Valves on Jowa OWS.
Closed Valves:V11, V13, V14, V15, V16, V17, V18, V19, V30.
Open Valves:V10, V12, V20.
4. Check Air Supply.
5. Switch on Power Supply.
6. Turn Switch to Auto.
7. When pump running, check flow on sample outlet from bilge-alarm.
To Stop Operation
1. Turn Switch from Auto to 0
2. Switch off Power Supply.
3. Close V20.