Air conditioning sometimes does not work

background image

Nazwa

Air conditioning sometimes does not work

Nr dokumentu

af8330p6000b

Tytuł dokumentu

Air conditioning sometimes does not work

background image

AF83.30-P-6000B

Air conditioning sometimes does not work

1.9.99

MODEL

124, 126, 129, 140, 163, 168, 170, 201, 202, 208, 210

Modification notes

1.9.99

Supersedes STIP 83.30-007 dated 15.8.97

Damage code

Cause

Remedy

83 751

Pressure sensor (B12) occasionally indicates 1

Connect pressure gauge and HHT.

wrong pressure value to control and
operating module (N19/22) (depending on
temperature).

2

Call up air conditioning actual values

Air conditioning/automatic air conditioning

with HHT.

occasionally does not function, refrigerant
compressor does not run.

3

Compare refrigerant pressure between

pressure gauge (high pressure side)
and HHT.

If pressure difference is greater than

2 bars.

4

Remove/install/replace pressure sensor

on receiver/drier.

Parts ordering notes

Part no.

Designation

Quantity

140 830 00 72

Pressure sensor

As required

Copyright Daimler AG 06.05.14 G/08/07. Ten wydruk WIS nie jest obj

ę

ty funkcj

ą

aktualizacji.

strona 1


Wyszukiwarka

Podobne podstrony:
SR 8 Adaptive Air Conditioning ULA[1]
6 4 1%20Ventilation%20in%20Air conditioned%20Premises
Barry Smith Why polish philosophy does not exist
0502 Refrigerant circuit Model 126 with air conditioning system
HEATER & AIR CONDITIONER
Audel Hvac Fundamentals, Air Conditioning, Heat Pumps And Distribution Systems (Malestrom)
does not belong objects1
Manual Air Conditioning
Air Conditioning
Automatic Air Conditioning
Design Of Air Conditioning Ducts
Reality Does Not Exist
19 air conditioning
Power Does Not Come From the?rrel of a Gun
SR 8 Adaptive Air Conditioning ULA[1]
6 4 1%20Ventilation%20in%20Air conditioned%20Premises

więcej podobnych podstron