4. Pomiary.
f |
A |
|
|
|
f |
ΔΦ |
[kHz] |
[działki] |
|
|
|
[kHz] |
[działki] |
100.006 |
1 |
|
|
|
100.094 |
17 |
100.006 |
2 |
|
|
|
100.074 |
17 |
100.015 |
3 |
|
|
|
100.067 |
17 |
100.019 |
4 |
|
|
|
100.059 |
16 |
100.023 |
5 |
|
|
|
100.05 |
15 |
100.027 |
6 |
|
|
|
100.046 |
13 |
100.028 |
8 |
|
|
|
100.042 |
10 |
100.03 |
10 |
|
|
|
100.042 |
8 |
100.031 |
14 |
|
|
|
100.041 |
6 |
100.034 |
20 |
|
|
|
100.04 |
0 |
100.035 |
25 |
|
|
|
100.037 |
10 |
100.036 |
30 |
|
|
|
100.036 |
16 |
100.037 |
37 |
|
|
|
100.035 |
18 |
100.037 |
45 |
|
|
|
100.032 |
19 |
100.038 |
53 |
|
|
|
100.018 |
20 |
100.04 |
45 |
|
|
|
100.008 |
20 |
100.041 |
37 |
|
|
|
|
|
100.042 |
30 |
|
|
|
|
|
100.043 |
25 |
|
|
|
|
|
100.043 |
20 |
|
|
|
|
|
100.044 |
14 |
|
|
|
|
|
100.047 |
10 |
|
|
|
|
|
100.051 |
8 |
|
|
|
|
|
100.052 |
6 |
|
|
|
|
|
100.053 |
5 |
|
|
|
|
|
100.062 |
4 |
|
|
|
|
|
100.073 |
3 |
|
|
|
|
|
100.092 |
2 |
|
|
|
|
|
5. Opracowanie wyników.
Wykres 1. Zależność kwadratu amplitudy od częstotliwości.
Na wykresie nie zaznaczono błędów, ponieważ są one mniejsze od zaznaczonych punktów pomiarowych.
Z wykresu odczytano szerokość połówkową krzywej rezonansowej:
df = (4 ±2) Hz
Korzystając z zależności Q = f0/df można obliczyć dobroć rezonatora:
Q = 25010
Dokładnego błędu obliczonej wielkości nie da się określić z powodu zastosowania graficznej metody wyznaczania szerokości połówkowej krzywej rezonansowej. Zakładając, że została ona określona z idealną dokładnością, to błąd nie przekracza 0.002%, czyli jest praktycznie pomijalny. Wynika z tego, że nawet przy popełnieniu dość dużego błędu przy wyznaczaniu szerokości połówkowej krzywej rezonansowej, obliczona wartość dobroci będzie z wystarczającą dokładnością.