Function description
D. Electrical function, control unit as of approx. 08/86 (Webasto no.
105.499)
Note
3. Repeat start:
The following functions of this control unit
If combustion does not occur during the
(N33)
first start, the combustion air blower
have been modified or added:
continues running for 30 seconds.
Thereafter, a second start is performed
1. Undervoltage cutout:
automatically. If this also does not result
If the power supply drops below 9.5
in combustion, the combustion air blower
0.5 volts during the cut-in period, the
continues running for 60 seconds. The
total time to a fault cut-off is increased
auxiliary heater switches off. The
from the previous 4 minutes to 5 1/2
auxiliary heater can only be restarted
minutes.
after it is switched off and on again.
4. After-running controller of combustion
2. Glow plug monitoring:
air blower after interruption of
If the glow coil of the glow plug or the
combustion:
power supply is interrupted, the control
If combustion is interrupted, e.g. because
unit switches to fault. The combustion air
of a shortage of fuel, a photo-transistor in
blower continues running for approx. 60
the flame monitor assures optically
seconds. The operating indicator lamp
controlled after-running of the
then goes out and the auxiliary heater
combustion air blower. This is limited to
switches off. No automatic repeat start is
max. 80 seconds. Thereafter, the
performed as before.
electronically controlled after-running of
60 seconds commences, as before.
5. Temperature-switching points
Coolant temperature in heater (°C)
Full load to part load
78
Part load to full load
70
Start of combustion interval
86
End of combustion interval (full-load start)
78