Protokol pomiaru pomiaru dwojnikow RL i RC metoda trzech woltomierzy
Lublin 2007-12-14
Wykonali:
1. Michal Starzynski
2. Kamil Skoczylas
3. Grzegorz Solek
Przyrzady:
Woltomierz:
Typ: M4650CR
Blad analogowy woltomierza: 0.5%
Blad cyfrowy woltomierza: 0.01V
Pomiar:1 Dwojnik:RC
-----------------------
U= 10.051 V
Ur= 7.073 V
Ul= 7.078 V
f= 50.0 Hz
I= 0.00115 A
R= 6140.0 Ohm
Z= 6144.3 Ohm
Rl=55.144 Ohm
X= 6144.0061788931 Ohm
C= 0.0000005183F
cosk= 0.0090
sink= 1.0000
S= 0.008153 W
P= 0.000073 W
Q= 0.000001 VAr
Pomiar:2 Dwojnik:RC
-----------------------
U= 10.055 V
Ur= 0.014 V
Ul= 10.062 V
f= 50.0 Hz
I= 0.00000 A
R= 10000.0 Ohm
Z= 7186785.7 Ohm
Rl=-3186738.777 Ohm
X= 6441629.0539245606 Ohm
C= 0.0000000005F
cosk= -0.4434
sink= 0.8963
S= 0.000014 W
P= -0.000006 W
Q= 0.000000 VAr
Pomiar:3 Dwojnik:RC
-----------------------
U= 10.063 V
Ur= 8.543 V
Ul= 5.264 V
f= 50.0 Hz
I= 0.00085 A
R= 10000.0 Ohm
Z= 6161.7 Ohm
Rl=38.702 Ohm
X= 6161.6211280674 Ohm
C= 0.0000005169F
cosk= 0.0063
sink= 1.0000
S= 0.004497 W
P= 0.000028 W
Q= 0.000000 VAr
Pomiar:4 Dwojnik:RL
-----------------------
U= 10.054 V
Ur= 5.675 V
Ul= 5.663 V
f= 50.0 Hz
I= 0.02823 A
R= 201.0 Ohm
Z= 200.6 Ohm
Rl=114.881 Ohm
X= 164.4202605912 Ohm
L= 0.5236314032H
cosk= 0.5727
sink= 0.8197
S= 0.159885 W
P= 0.091574 W
Q= 0.000326 VAr
Pomiar:5 Dwojnik:RL
-----------------------
U= 10.073 V
Ur= 3.812 V
Ul= 7.387 V
f= 50.0 Hz
I= 0.03812 A
R= 100.0 Ohm
Z= 193.8 Ohm
Rl=111.349 Ohm
X= 158.6255358544 Ohm
L= 0.5051768658H
cosk= 0.5745
sink= 0.8185
S= 0.281582 W
P= 0.161780 W
Q= 0.001152 VAr