Protokol pomiaru pomiaru dwojnikow RL i RC metoda trzech woltomierzy
Lublin 2007-12-12
Wykonali:
1. Przemyslaw Stachyra
2. Michal Tomala
3. Sebastian Trojanowski
Przyrzady:
Woltomierz:
Typ: M-4650CR
Blad analogowy woltomierza: 0.5
Blad cyfrowy woltomierza: 10
Pomiar:1 Dwojnik:RC
-----------------------
U= 10.811 V
Ur= 9.170 V
Ul= 5.667 V
f= 50.0 Hz
I= 0.00092 A
R= 10000.0 Ohm
Z= 6180.0 Ohm
Rl=39.589 Ohm
X= 6179.8910771832 Ohm
C= 0.0000005153F
cosk= 0.0064
sink= 1.0000
S= 0.005197 W
P= 0.000033 W
Q= 0.000000 VAr
Pomiar:2 Dwojnik:RC
-----------------------
U= 10.666 V
Ur= 5.442 V
Ul= 9.186 V
f= 50.0 Hz
I= 0.00544 A
R= 1000.0 Ohm
Z= 1688.0 Ohm
Rl=-4.100 Ohm
X= 1688.0198647082 Ohm
C= 0.0000018867F
cosk= -0.0024
sink= 1.0000
S= 0.049993 W
P= -0.000121 W
Q= 0.000025 VAr
Pomiar:3 Dwojnik:RL
-----------------------
U= 8.310 V
Ur= 3.170 V
Ul= 6.089 V
f= 50.0 Hz
I= 0.03170 A
R= 100.0 Ohm
Z= 192.1 Ohm
Rl=109.146 Ohm
X= 158.0291713723 Ohm
L= 0.5032776158H
cosk= 0.5683
sink= 0.8228
S= 0.193033 W
P= 0.109701 W
Q= 0.000794 VAr
Pomiar:4 Dwojnik:RL
-----------------------
U= 8.333 V
Ur= 4.427 V
Ul= 5.081 V
f= 50.0 Hz
I= 0.04427 A
R= 100.0 Ohm
Z= 114.8 Ohm
Rl=61.256 Ohm
X= 97.0577579768 Ohm
L= 0.3091011401H
cosk= 0.5337
sink= 0.8457
S= 0.224974 W
P= 0.120074 W
Q= 0.000951 VAr
Wyszukiwarka
Podobne podstrony:
Wyniki analityczne interpretacja raporty
przemoc wyniki badań i raport
Wyniki A107ID2
DiW 4 raport lifting
raport Saturn
2014 xv smp final wyniki
Wyniki cw1
streszczenie raportu pzh dla portalu
Wyniki ?MBO
Raport?danie? Krakow 06 [ www potrzebujegotowki pl ]
108 A Raport?ncassurance (2)
Road safety vademecum (raport)
więcej podobnych podstron