1. Dane znamionowe prądnicy i silnika bocznikowego
Prądnica: |
Silnik: |
Typ GZD S46 |
Typ GMR-6 |
Un = 380 [V] |
Un = 110 [V] |
S = 3300 [VA] |
I = 60 [A] |
In = 5 [A] |
P = 5,5 [kW] |
n = 1500 [obr/min] |
n = 1400 [obr/min] |
cosϕ = 0,8 |
|
f = 50 [Hz] |
|
2. Synchronizacja prądnicy.
a) Synchronizacja na ciemno:
b) Synchronizacja na jasno
c) Synchronizacja na światło wendrujące
d) Synchronizacja
2. Charakterystyki regulacyjne.
cosϕ = 1
L.P |
I1 |
I2 |
I3 |
I |
Ir |
P1 |
P2 |
P |
U |
|
A |
A |
A |
A |
A |
W |
W |
W |
V |
1 |
1.1 |
1.15 |
1 |
1.08 |
0.75 |
430 |
440 |
870 |
380 |
2 |
1.5 |
1.6 |
1.5 |
1.53 |
0.8 |
530 |
540 |
1070 |
380 |
3 |
2.3 |
2.4 |
2.3 |
2.33 |
0.85 |
800 |
800 |
1600 |
380 |
4 |
2.9 |
3 |
2.9 |
2.93 |
0.9 |
1100 |
1050 |
2150 |
380 |
5 |
3.5 |
3.6 |
3.6 |
3.56 |
0.94 |
1200 |
1200 |
2400 |
380 |
6 |
4 |
4.2 |
4.1 |
4.1 |
1.04 |
1400 |
1400 |
2800 |
380 |
7 |
4.5 |
4.6 |
4.6 |
4.56 |
1.1 |
1500 |
1500 |
3000 |
380 |
cosϕ = 0,5 ( indukcyjny )
L.P |
I1 |
I2 |
I3 |
I |
Ir |
P1 |
P2 |
P |
U |
|
A |
A |
A |
A |
A |
W |
W |
W |
V |
1 |
1.15 |
1.2 |
1 |
1.11 |
0.58 |
0 |
330 |
330 |
380 |
2 |
2.3 |
2.4 |
2.3 |
2.33 |
0.39 |
0 |
770 |
770 |
380 |
3 |
2.7 |
2.8 |
2.7 |
2.73 |
0.35 |
0 |
900 |
900 |
380 |
4 |
3.5 |
3.6 |
3.5 |
3.53 |
0.27 |
0 |
1180 |
1180 |
380 |
5 |
4 |
4.1 |
4 |
4.03 |
0.26 |
0 |
1330 |
1330 |
380 |
6 |
4.6 |
4.7 |
4.6 |
4.63 |
0.23 |
0 |
1500 |
1500 |
380 |
cosϕ = 0,5 ( pojemnościowy )
L.P |
I1 |
I2 |
I3 |
I |
Ir |
P1 |
P2 |
P |
U |
|
A |
A |
A |
A |
A |
W |
W |
W |
V |
1 |
1.5 |
1.6 |
1.6 |
1.56 |
1.05 |
580 |
0 |
580 |
380 |
2 |
2 |
2.1 |
2.1 |
2.06 |
1.17 |
780 |
0 |
780 |
380 |
3 |
3.1 |
3.2 |
3.2 |
3.16 |
1.4 |
1150 |
0 |
1150 |
380 |
4 |
3.9 |
4 |
4 |
3.96 |
1.55 |
1350 |
0 |
1350 |
380 |
5 |
4.2 |
4.3 |
4.3 |
4.26 |
1.65 |
1450 |
0 |
1450 |
380 |
6 |
4.4 |
4.4 |
4.5 |
4.43 |
1.7 |
1500 |
0 |
1500 |
380 |
4. Krzywe „V”
Mn1 = Mo |
Mn2 > Mo |
||||||||||||||||
Iw |
I |
P1 |
P2 |
P |
U |
Iw |
I |
P1 |
P2 |
P |
U |
Iw1 |
Is |
Us |
Ps |
||
A |
A |
W |
W |
W |
V |
A |
A |
W |
W |
W |
V |
A |
A |
V |
W |
||
0.6 |
1.5 |
480 |
280 |
760 |
3880 |
0.82 |
1.5 |
400 |
550 |
950 |
380 |
1.05 |
2 |
95 |
190 |
||
0.4 |
2 |
650 |
50 |
700 |
380 |
1.05 |
2 |
800 |
750 |
950 |
380 |
1.05 |
2 |
95 |
190 |
||
0.3 |
2.5 |
780 |
80 |
860 |
380 |
1.2 |
2.5 |
80 |
880 |
960 |
380 |
1.05 |
2 |
95 |
190 |
||
0.15 |
3.5 |
920 |
250 |
1170 |
380 |
1.35 |
3 |
50 |
1000 |
1050 |
380 |
1.05 |
2 |
95 |
190 |
||
0.05 |
4 |
1020 |
320 |
1340 |
380 |
1.5 |
3.5 |
180 |
1150 |
1330 |
380 |
1.05 |
2 |
95 |
190 |
||
|
|
|
|
|
|
1.6 |
4 |
250 |
1250 |
1500 |
380 |
1.05 |
2 |
95 |
190 |
||
|
|
|
|
|
|
1.72 |
4.5 |
350 |
1350 |
1700 |
380 |
1.05 |
2 |
95 |
190 |
||
|
|
|
|
|
|
1.83 |
5 |
400 |
1450 |
1850 |
380 |
1.05 |
2 |
95 |
190 |
5. Spis mierników.
A - LM-1; kl.0,5; zakres 3[A]
A - ME-160; kl.1,5; zakres 40[A]
V - TLME-2; kl.0,5; zakres 300[V]
Zasilacz U 0÷30[V]; I = 2,5[A]
6. Wnioski.
Przy łączeniu prądnicy z siecią można uniknąć stanów nieustalonych, a tym samym dużych prądów łączeniowych, jeśli w chwili łączenia maszyny z siecią wartości chwilowe napięć odpowiadających faz po obu stronach otwartego wyłącznika są równe. Wartości chwilowe napięć po obu stronach łącznika są równe jeśli:
- wartości skuteczne napięć po obu stronach są jednakowe;
- częstotliwości tych napięć są równe;
- kąt przesunięcia fazowego napięć tej samej fazy prądnicy i sieci wynosi zero stopni.
Wybór chwili włączenia prądnicy do sieci, przy spełnieniu wymienionych warunków nazywa się synchronizacją.