Protokol pomiaru pomiaru dwojnikow RL i RC metoda trzech woltomierzy
Lublin 2007-12-11
Wykonali:
1. Pawel Szykula
2. Kamil Wosko
3. L L
Przyrzady:
Woltomierz:
Typ: METEX M-4650CR
Blad analogowy woltomierza: 0,5%
Blad cyfrowy woltomierza: 0,001
Pomiar:1 Dwojnik:RL
-----------------------
U= 14.808 V
Ur= 0.012 V
Ul= 14.815 V
f= 50.0 Hz
I= 0.00012 A
R= 100.0 Ohm
Z= 127713.8 Ohm
Rl=-75999.996 Ohm
X= 102639.2395772934 Ohm
L= 326.8765591634H
cosk= -0.5951
sink= 0.8037
S= 0.001719 W
P= -0.001023 W
Q= 0.000007 VAr
Pomiar:2 Dwojnik:RL
-----------------------
U= 14.830 V
Ur= 5.623 V
Ul= 10.880 V
f= 50.0 Hz
I= 0.05623 A
R= 100.0 Ohm
Z= 193.5 Ohm
Rl=110.629 Ohm
X= 158.7534841676 Ohm
L= 0.5055843445H
cosk= 0.5717
sink= 0.8204
S= 0.611739 W
P= 0.349750 W
Q= 0.002509 VAr
Pomiar:3 Dwojnik:RC
-----------------------
U= 14.879 V
Ur= 7.609 V
Ul= 12.754 V
f= 50.0 Hz
I= 0.00761 A
R= 1000.0 Ohm
Z= 1676.3 Ohm
Rl=7.235 Ohm
X= 1676.2937776241 Ohm
C= 0.0000018999F
cosk= 0.0043
sink= 1.0000
S= 0.097040 W
P= 0.000419 W
Q= 0.000049 VAr
Pomiar:4 Dwojnik:RC
-----------------------
U= 14.861 V
Ur= 11.359 V
Ul= 7.778 V
f= 50.0 Hz
I= 0.00114 A
R= 10000.0 Ohm
Z= 6847.1 Ohm
Rl=1213.857 Ohm
X= 6738.6540744230 Ohm
C= 0.0000004726F
cosk= 0.1773
sink= 0.9842
S= 0.008835 W
P= 0.001566 W
Q= 0.000000 VAr
Pomiar:5 Dwojnik:RL
-----------------------
U= 14.775 V
Ur= 7.826 V
Ul= 9.034 V
f= 50.0 Hz
I= 0.07826 A
R= 100.0 Ohm
Z= 115.4 Ohm
Rl=61.577 Ohm
X= 97.6467356011 Ohm
L= 0.3109768650H
cosk= 0.5334
sink= 0.8459
S= 0.707015 W
P= 0.377128 W
Q= 0.002990 VAr
Wyszukiwarka
Podobne podstrony:
Wyniki A107ID22014 xv smp final wynikiWyniki cw1Wyniki ?MBOWyniki KKKWyniki2 korelacja2Próba 1 wyniki skryptuStan i możliwości rozwoju małych i średnich obiektów hotelarskich w Euroregionie Nysa wyniki badańFP 30 WPwCZ wynikiwyniki szkol 2011Wyniki 3CWRLwyniki zaliczenia metody fiz 16 Wrzesień 2011więcej podobnych podstron