Sprawność układu silnik napędowy - pompa wyznaczamy z równania: gdzie:
Ns - rzeczywista moc pompy Nu - moc użyteczna pompy
a) 1200 obrotów/mm
P, | Pa | |
P.IPal |
V,. 10*^1 |
NsIW] |
Hu |ml |
N„ IW) |
T\l%) |
10000 |
160000 |
0,00 |
435 |
15.32 |
0 |
0.00 |
10000 |
140000 |
2.22 |
525 |
13.28 |
29 |
16.51 |
10000 |
140000 |
2.78 |
540 |
13.28 |
36 |
20.06 |
10000 |
110000 |
4.17 |
600 |
10.21 |
42 |
20.83 |
10000 |
70000 |
5,28 |
600 |
6,13 |
32 |
15,83 |
10000 |
30000 |
6.11 |
585 |
2.04 |
12 |
6.27 |
10000 |
0 |
6,94 |
588 |
-1,02 |
-7 |
-3,54 |
b) 2400 obrotów/min
Ps [Pal |
p, [Pal |
V, [ io4—1 |
K [W] |
Hu[ml |
Nu [W) |
T1[%1 |
10000 |
440000 |
0.00 |
909 |
43.92 |
0 |
0.00 |
10000 |
400000 |
3.06 |
1290 |
39.84 |
119 |
27.71 |
1(KXK) |
360(XX) |
5,28 |
1560 |
35.75 |
185 |
35,52 |
10000 |
300000 |
7.22 |
1680 |
29.62 |
209 |
37.40 |
10000 |
260000 |
8.06 |
1713 |
25,54 |
201 |
35,27 |
10000 |
160000 |
9.72 |
1719 |
15.32 |
146 |
25.45 |
10000 |
80000 |
10.83 |
1671 |
7.15 |
76 |
13.61 |
HJml