Interlace variables
Scope |
Mamę |
Typ® |
Initial Comment |
Input |
1 Port |
WagoTypesł.todule 75x 6321 Module 75x 632 |
Access to the moduł |
bSoleno«dNo |
BYTE |
1 1->soleno*d one.2*>soleno*d two | |
xPow«r€nable |
BOOL |
Enable power stage Reset error | |
xCunentEnaNe |
BOOL |
EnaWe cunent control | |
iCurrent |
INT |
Reference cunent m % 100%-Mhat is 10 000 in Iht proces* image | |
xStop |
BOOL |
Stop ->tirang details in manuał 750-632 | |
xJogPos |
BOOL |
Jog m positrve direction ->timmg details m manuał 750-632 | |
xJogfleg |
BOOL |
Jog m n«gatrve direction ->timing details in manuał 750-632 | |
xOlherEnabłe |
BOOL |
Enable dither functionalrty | |
bRampSelect |
BYTE |
Choose vvtch ramp to be used | |
Out pot |
xEnabled |
BOOL |
Power stage enabled |
tActualCurrent |
INT |
Actual cunent | |
xError |
BOOL |
Enor occured | |
oStatus |
WagoSysEnorBase FbResult |
Status details |
Fu nc li on
Contro! a propoitional vatve