DIXELL Blast Chiller

background image

1

XB

D

C

B

A

-

L

0

7

B

X

5

E

D

B

C

E

A

• Design to comply with the rules concerning preparation and chilling of foodstuffs (HACCP)
• Four configurable cycles: pre-set according to the most common food – safety applications: soft chill, hard chill and freezing
• Output for remote display to monitor the core temperature of goods
• Internal real time clock
• Printer output (XB07PR) for temperature and blast chiller cycles reports
• All different phases monitorated and shown on the display
• Ultra violet sterilization cycle management
• Standard communication protocol ModBUS-RTU
• Hot Key 128 or Prog tool kit connector for a quick and easy programming
• 5VA max power absorption
• Dual display with red LED (8,0mm high) and yellow LED (5,6mm high) and 14 icons

XB

SERIE: CONTROLLERS FOR BLAST CHILLER AND TEMPERATURE

MAINTENANCE APPLICATIONS – SERIAL OUTPUT

0

= No

1

= Yes

0

= No

1

= Yes

X-REP output

For blue display please contact Dixell

Power supply

Input

Measurement unit

Printer output

HOW TO ORDER

B

B

BL

LLA

A

AS

S

ST

T

T C

C

CH

H

HIIIL

LLL

LLE

E

ER

R

R C

C

CO

O

ON

N

NT

T

TR

R

RO

O

OL

LLL

LLE

E

ER

R

RS

S

S

2

= 24Vac

4

= 110Vac

5

= 230Vac

C

= °C

F

= °F

N

= NTC

P

= PTC

L: 38x185mm

background image

2

The XB570L controller is dedicated to blast chiller applications and gives a solution
to HACCP system.
With the XB570L, food is rapidly cooled (both at +3°C and at –18°C) immediately
after it has been cooked, to avoid the proliferation of bacteria that occurs when
food is allowed to cool naturally or in a normal refrigerator.
Ease of use and complete management of each blast chilling phase is guaranteed
by 4 cycles that can be adjusted to suit any type of food. It is possible to display the
temperature of either the air or the food insertion probe.
The hygiene of the blast chiller is guaranteed by an extra configurable output for
sterilization by means of ultraviolet rays.
The optional XB07PR printer can be connected to the XB570L controllers to provide
the user with a written report of all the main data required: cycle start and stop
times, duration, the temperature of the product or the coldroom, all at regular
intervals, via an internal time clock.

The XB570L has 4 different soft and hard chill cycles in it’s memory. These can also be modified by the User.
Each cycle is defined with independent time and temperature parameters to set each control phase and can be combined even with the hold phase.
The four cycles are directly selectable from the keyboard. The control of each cycle is carried out using the insert probe or by time duration.

Each cycle (Cy1, Cy2, Cy3 and Cy4) can be programmed
with three different phases according to the food
type.

• First phase: hard chill

Limits bacteria reproduction during the initial phase
(from high temperature down to 2 °C). During “Hard
Chill”, both compressor and fan are always “on” until
the end cycle temperature is reached.

• Soft chill phase

Reduces the variation between the surface and core
temperatures of the product. During “Soft Chill” the
temperature of the room is regulated by the ambient
probe: compressor is cycled to maintain a particular
air temperature.

• Freezing cycle phase

Freezes the product in the shortest possible time.
During the “Freezing Cycle” both compressor and fan
are always on until the end temperature is reached.

• Holding phase

The holding phase maintains the final temperature
reached by the chilling cycle.

HACCP: A POSITIVE SOLUTIONS

FREEZING CYCLE: HOW IT IS ACHIEVED

The drawing shows a typical freezing cycle

PHASE 1:

HARD CHILL

PHASE 2:

SOFT CHILL

PHASE 3:

FREEZING CYCLE

ROOM PROBE

INSERT PROBE

B

B

BL

LLA

A

AS

S

ST

T

T C

C

CH

H

HIIIL

LLL

LLE

E

ER

R

R C

C

CO

O

ON

N

NT

T

TR

R

RO

O

OL

LLL

LLE

E

ER

R

RS

S

S

background image

3

XB

XB570L

XB570L

L: 38x185mm

First display: n° digits
Second display: n° digits
Keyboard: push buttons
Power supply
Probe inputs

Thermostat
Defrost
Insert 1
Insert 2
Insert 3

Digital inputs

Alarm
Door switch

Relay outputs

Compressor
Defrost
Fans
Light
AUX
Alarm

Other

Hot Key 128/Prog Tool Kit output
Remote display output
Printer output
Serial output
Buzzer
Real time clock

Blast chiller digital controller with four configurable cycles, RTC, printer output and serial

output

FEATURES

BLAST CHILLER DIGITAL CONTROLLER

XB570L

B

B

BL

LLA

A

AS

S

ST

T

T C

C

CH

H

HIIIL

LLL

LLE

E

ER

R

R C

C

CO

O

ON

N

NT

T

TR

R

RO

O

OL

LLL

LLE

E

ER

R

RS

S

S

± 3 d.p.
± 4 d.p.
8
24, 110, 230Vac

NTC/PTC
NTC/PTC
NTC/PTC
NTC/PTC
NTC/PTC

config
pres

20A
8A
8A
16A
8A
16A

pres
X-REP opt
XB07PR opt
RS485
pres
pres


Wyszukiwarka

Podobne podstrony:
DIXELL Blast Chiller
DIXELL WING Basic
DIXELL Prime D
DIXELL XR100 XR500
DIXELL XR10C D
Top of Volcano Blown of in Blast!
algorytm Fasta i BLAST
DIXELL XM Series
DIXELL XC700 800 900
DIXELL Prime CX
DIXELL WING 200, 500
Blast Your Bench
Corrosion behaviour of commercially pure titanium shot blast
boliva chille intel report 2006

więcej podobnych podstron