• Designtocomplywiththerulesconcerningpreparationandchillingoffoodstuffs(HACCP)
• Fourconfigurablecycles:pre-setaccordingtothemostcommonfood–safetyapplications:softchill,hardchillandfreezing
• Outputforremotedisplaytomonitorthecoretemperatureofgoods
• Internalrealtimeclock
• Printeroutput(XB07PR)fortemperatureandblastchillercyclesreports
• Alldifferentphasesmonitoratedandshownonthedisplay
• Ultravioletsterilizationcyclemanagement
• StandardcommunicationprotocolModBUS-RTU
• HotKey128orProgtoolkitconnectorforaquickandeasyprogramming
• 5VAmaxpowerabsorption
• DualdisplaywithredLED(8,0mmhigh)andyellowLED(5,6mmhigh)and14icons
XB
SERIE: CONTROLLERS FOR BLAST CHILLER AND TEMPERATURE
MAINTENANCE APPLICATIONS – SERIAL OUTPUT
0
= No
1
= Yes
0
= No
1
= Yes
X-REP output
For blue display please contact Dixell
Power supply
Input
Measurement unit
Printer output
HOW TO ORDER
B
B
BL
LLA
A
AS
S
ST
T
T C
C
CH
H
HIIIL
LLL
LLE
E
ER
R
R C
C
CO
O
ON
N
NT
T
TR
R
RO
O
OL
LLL
LLE
E
ER
R
RS
S
S
2
= 24Vac
4
= 110Vac
5
= 230Vac
C
= °C
F
= °F
N
= NTC
P
= PTC
L: 38x185mm
2
The XB570L controller is dedicated to blast chiller applications and gives a solution
to HACCP system.
With the XB570L, food is rapidly cooled (both at +3°C and at –18°C) immediately
after it has been cooked, to avoid the proliferation of bacteria that occurs when
food is allowed to cool naturally or in a normal refrigerator.
Ease of use and complete management of each blast chilling phase is guaranteed
by 4 cycles that can be adjusted to suit any type of food. It is possible to display the
temperature of either the air or the food insertion probe.
The hygiene of the blast chiller is guaranteed by an extra configurable output for
sterilization by means of ultraviolet rays.
The optional XB07PR printer can be connected to the XB570L controllers to provide
the user with a written report of all the main data required: cycle start and stop
times, duration, the temperature of the product or the coldroom, all at regular
intervals, via an internal time clock.
The XB570L has 4 different soft and hard chill cycles in it’s memory. These can also be modified by the User.
Each cycle is defined with independent time and temperature parameters to set each control phase and can be combined even with the hold phase.
The four cycles are directly selectable from the keyboard. The control of each cycle is carried out using the insert probe or by time duration.
Each cycle (Cy1, Cy2, Cy3 and Cy4) can be programmed
with three different phases according to the food
type.
• First phase: hard chill
Limits bacteria reproduction during the initial phase
(from high temperature down to 2 °C). During “Hard
Chill”, both compressor and fan are always “on” until
the end cycle temperature is reached.
• Soft chill phase
Reduces the variation between the surface and core
temperatures of the product. During “Soft Chill” the
temperature of the room is regulated by the ambient
probe: compressor is cycled to maintain a particular
air temperature.
• Freezing cycle phase
Freezes the product in the shortest possible time.
During the “Freezing Cycle” both compressor and fan
are always on until the end temperature is reached.
• Holding phase
The holding phase maintains the final temperature
reached by the chilling cycle.
HACCP: A POSITIVE SOLUTIONS
FREEZING CYCLE: HOW IT IS ACHIEVED
The drawing shows a typical freezing cycle
PHASE 1:
HARD CHILL
PHASE 2:
SOFT CHILL
PHASE 3:
FREEZING CYCLE
ROOM PROBE
INSERT PROBE
B
B
BL
LLA
A
AS
S
ST
T
T C
C
CH
H
HIIIL
LLL
LLE
E
ER
R
R C
C
CO
O
ON
N
NT
T
TR
R
RO
O
OL
LLL
LLE
E
ER
R
RS
S
S
3
XB
XB570L
XB570L
L: 38x185mm
First display: n° digits
Second display: n° digits
Keyboard: push buttons
Power supply
Probe inputs
Thermostat
Defrost
Insert 1
Insert 2
Insert 3
Digital inputs
Alarm
Door switch
Relay outputs
Compressor
Defrost
Fans
Light
AUX
Alarm
Other
Hot Key 128/Prog Tool Kit output
Remote display output
Printer output
Serial output
Buzzer
Real time clock
Blast chiller digital controller with four configurable cycles, RTC, printer output and serial
output
FEATURES
BLAST CHILLER DIGITAL CONTROLLER
XB570L
B
B
BL
LLA
A
AS
S
ST
T
T C
C
CH
H
HIIIL
LLL
LLE
E
ER
R
R C
C
CO
O
ON
N
NT
T
TR
R
RO
O
OL
LLL
LLE
E
ER
R
RS
S
S
± 3 d.p.
± 4 d.p.
8
24, 110, 230Vac
NTC/PTC
NTC/PTC
NTC/PTC
NTC/PTC
NTC/PTC
config
pres
20A
8A
8A
16A
8A
16A
pres
X-REP opt
XB07PR opt
RS485
pres
pres