DTR GLORY ECO MSG07 21HRN2

background image

59

GLORY (ECO) STAR SERIES

1. Features 60

2. Specification 61

3. Dimensions 67

4. Refrigeration cycle diagram 70

5. Operation limits 71

6. Wiring diagram 72

7. Troubleshooting 80

8. Electronic function 80

60

61

67

70

71

72

80

80

background image

60

1.Features

1.1 Compact design

1.2 High efficiency and quiet operation

background image

61

2.Specification

Model

MSG-05CR

MSG-07HR

MSG-07CR

MSG-09HR

MSG-09CR

Power supply

Ph-V-Hz

220-240V~,50Hz

220-240V~,50Hz

220-240V~,50Hz

220-240V~,50H

220-240V~,50Hz

Capacity

Btu/h

5000

7000

7000

9000

9000

Input

W

560

760

760

1000

1000

Rated current

A

2.6

3.6

3.6

4.5

4.5

Cooling

EER

Btu/w.h

8.6

8.8

8.8

9

9

Capacity

Btu/h

7600

10000

Input

W

760

980

Rated current

A

3.4

4.4

Heating

COP

Btu/w.h

10

10.2

Moisture Removal

L/h

0.6

0.8

0.8

1

1

Max. input consumption

W

800

1050

1050

1300

1300

Max. current

A

3.8

5

5

7

7

Starting current

A

16

18

18

25

25

Model

KH104VFHC

2P14C235ANA

2P14C235ANA

PH170X1C-4DZ

PH170X1C-4DZ2

Type

Rotary

Rotary

Rotary

Rotary

Rotary

Brand

SHANGHAI

GD Matsushita

GD Matsushita

GD Toshiba

GD Toshiba

Capacity

Btu/h

5700

7500

7500

10000

10000

Input

W

590

725

725

970

970

Rated current(RLA)

A

2.7

3.4

3.4

4.5

4.5

Locked rotor Amp(LRA)

A

13

15

15

24

24

Thermal protector

BF540-KB

MRA98854

MRA98854

UP3QE0591-T6

UP3QE0591-T61(in

Capacitor

uF

15

25

25

25

25

Compressor

Refrigerant oil

ml

MS-56 270

ATOMOS M60 270

ATOMOS M60 270

SUNISO 350

SUNISO 350

Model

RPG13H

RPG13H

RPG13H

RPG13H

RPG13H

Brand

WELLING

WELLING

WELLING

WELLING

WELLING

Input

W

36.5

36.5

36.5

36.5

36.5

Capacitor

uF

1.2µF/450V

1.2µF/450V

1.2µF/450V

1.2µF/450V

1.2µF/450V

Indoor fan motor

Speed(hi/mi/lo)

r/min

1020/ 960/ 900

1020/ 960/ 900

1020/ 960/ 900

1100/1020/950

1100/1020/950

Indoor air flow (Hi/Mi/Lo)

m3/h

300/270/240

380/350/320

380/350/320

450/420/390

450/420/390

Indoor noise level (Hi/Mi/Lo)

dB(A)

32/28/25

32/28/25

32/28/25

33/31/27

33/31/27

Dimension (W*H*D)

mm

750×250×188

750×250×188

750×250×188

750×250×188

750×250×188

Packing (W*H*D)

mm

830X336X280

830X336X280

830X336X280

830X336X280

830X336X280

Indoor unit

Net/Gross weight

Kg

8/9.5

8.5/10

8.5/10

8.5/10

8.5/10

Model

YDK24-6T

YDK24-6T

YDK24-6T

YDK24-6T

YDK24-6T

Brand

WELLING

WELLING

WELLING

WELLING

WELLING

Input

W

70

70

70

70

70

Capacitor

uF

3

3

3

3

3

Outdoor fan motor

Speed

r/min

850

850

850

850

850

Outdoor air flow

m3/h

1400

1400

1400

1500

1500

Outdoor noise level

dB(A)

49

49

49

49

49

Dimension(W*H*D)

mm

700×535×235

700×535×235

700×535×235

700×535×235

700×535×235

Packing (W*H*D)

mm

815×580×325

815×580×325

815×580×325

815×580×325

815×580×325

Outdoor unit

Net/Gross weight

Kg

26/29

28/31

27/30

30/33

29/32

Refrigerant type R22

g

480

620

580

650

580

Design pressure

MPa

2.6

2.6

2.6

2.6

Liquid side/ Gas side

mm(inch)

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Max. refrigerant pipe length

m

10

10

10

10

10

Refrigerant piping

Max. difference in level

m

5

5

5

5

5

Connection wiring

No

No

No

No

No

Plug type

10A

10A

10A

10A

10A

Thermostat type

Electronic control

Electronic control

Electronic control

Electronic

Electronic control

Operation temp

17-30

17-30

17-30

17-30

17-30

Ambient temp

-7-43

-7-43

-7-43

-7-43

-7-43

Application area

m2

8-12

10--14

10-14

14-21

14-21

★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient

condition.

background image

62

Model

MSG-12CR

MSG-12HR

MSG-18CR

MSG-18HR

Power supply

Ph-V-Hz

220-240V,50HZ

220-240V,50HZ

220-240V~,50Hz

220-240V~,50Hz

Capacity

Btu/h

12000

12000

18000

18000

Input

W

1230

1230

1930

11920

Rated current

A

5.7

5.7

9.1

9.0

Cooling

EER

Btu/w.h

9.8

9.8

9.4

9.4

Capacity

Btu/h

13000

20000

Input

W

1290

1980

Rated current

A

6

9.2

Heating

COP

Btu/w.h

10.1

10.6

Moisture Removal

L/h

1.2

1.2

1.5

1.5

Max. input consumption

W

1650

1690

2040

2080

Model

PH200X2C-8FTC

2K23S225AHA

SHY33MC2-U

SHY33MC2-U

Capacity

Btu/h

11840

13610

17620

17620

Input

W

1135

1305

1725

1725

Rated current(RLA)

A

5.2

6.1

8。1

8。1

Locked rotor Amp(LRA)

A

26

36

36

Thermal protector

Internal

External

INNER

INNER

Capacitor

uF

25

35

50

50

Compressor

Refrigerant oil

ml

440

430

600

600

Input

W

36.5

36.5

53

53

Capacitor

uF

1.2

1.2

1.5uF/450V

1.5uF/450V

Indoor fan motor

Speed(hi/mi/lo)

r/min

1350

1350

1325

1325

Indoor air flow (Hi/Mi/Lo)

m3/h

550

550

750/710/650

750/710/650

Indoor noise level (Hi/Mi/Lo)

dB(A)

36/33/30

36/33/30

38/35/32

38/35/32

Dimension (W*H*D)

mm

750X250X188

750X250X188

906×286×235

906×286×235

Packing (W*H*D)

mm

830X336X280

830X336X280

1020X380X328

1020X380X328

Indoor unit

Net/Gross weight

Kg

8.5/10

8.5/10

13.5/16.5

13.5/16.5

Input

W

70

70

96

96

Outdoor fan motor

Capacitor

uF

2.5

2.5

2.5µF/450V

2.5µF/450V

Outdoor noise level

dB(A)

51

51

51

51

Dimension(W*H*D)

mm

780X540X250

780X540X250

760×590×275

760×590×275

Packing (W*H*D)

mm

910X575X335

910X575X335

890×655×360

890×655×360

Outdoor unit

Net/Gross weight

Kg

34/37

36/39

43/47

44/48

Refrigerant type

g

R22/750

R22/820

1110

1370

Design pressure

MPa

2.6

2.6

2.6

2.6

Liquid side/ Vapor side

mm(inch)

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Max. refrigerant pipe length

m

10

10

15

15

Refrigerant piping

Max. difference in level

m

5

5

5

5

Plug type

16A

16A

15

15

Application area

m2

18-26

18-26

25-35

25-35

★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient

condition.






background image

63

Model

MSG-21CR

MSG-21HR

Power supply

Ph-V-Hz

220-240V~,50Hz

220-240V~,50Hz

Capacity Btu/h

21000

21000

Input

W

2300

2300

Rated current

A

10.5

10.5

Cooling

EER

Btu/w.h

9.1

9.1

Capacity

Btu/h

23500

Input

W

2400

Rated current

A

11.0

Heating

COP

Btu/w.h

9.8

Moisture Removal

L/h

2.0

2.0

Max. input consumption

W

2500

2600

Max. current

A

11.3

14.5

Starting current

A

42

42

Model

2V36S225AUD

2V36S225AUD

Type

rotary

rotary

Capacity

Btu/h

20600

20600

Input

W

2010

2010

Rated current(RLA)

A

9。5

9。5

Locked rotor Amp(LRA)

A

42

42

Thermal protector

INNER

INNER

Capacitor

uF

50

50

Compressor

Refrigerant oil

ml

680

680

Model

RPG25

RPG25

Brand

WELLING

WELLING

Input

W

53

53

Capacitor

uF

1.5uF/450V

1.5uF/450V

Indoor fan motor

Speed(hi/mi/lo)

r/min

1325

1325

Indoor air flow (Hi/Mi/Lo)

m3/h

920\760\700

920\760\700

Indoor noise level (Hi/Mi/Lo)

dB(A)

41/37/33

41/37/33

Dimension (W*H*D)

mm

906×286×235

906×286×235

Packing (W*H*D)

mm

1020X380X328

1020X380X328

Indoor unit

Net/Gross weight

Kg

13.5/16.5

13.5/16.5

Model

YDK53-6

YDK53-6

Input

W

100

100

Capacitor

uF

2.5μF/450V

2.5μF/450V

Outdoor fan motor

Speed

r/min

640

640

Outdoor air flow

m3/h

2600

2600

Outdoor noise level

dB(A)

53

53

Dimension(W*H*D)

mm

845×695×335

845×695×335

Packing (W*H*D)

mm

970×770×395

970×770×395

Outdoor unit

Net/Gross weight

Kg

52/57

55/60

Refrigerant type R22

g

1220

1740

Design pressure

MPa

2.6

2.6

Liquid side/ Gas side

mm(inch)

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Max. refrigerant pipe length

m

15

15

Refrigerant piping

Max. difference in level

m

5

5

Thermostat type

Electronic control

Electronic control

Operation temp

17-30

17-30

Ambient temp

10-43

(-5~43)

Application area

m2

34-49

34-49

★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient

condition.

background image

64

Glory Eco Star

Model

MSG-07HRN2

MSG-07CRN2

MSG-09HRN2

MSG-09CRN2

Power supply

Ph-V-Hz

220-240V~,50Hz

220-240V~,50Hz

220-240V~,50Hz

220-240V~,50Hz

Capacity

Btu/h

7000

7000

9000

9000

Input

W

800

800

1020

1020

Rated current

A

3.5

3.5

4.5

4.5

Cooling

EER

Btu/w.h

8.8

8.8

8.8

8.8

Capacity

Btu/h

8500

11000

Input

W

880

1080

Rated current

A

4

4.8

Heating

COP

Btu/w.h

9.9

10.0

Moisture Removal

L/h

0.6

0.6

0.8

0.8

Max. input consumption

W

1000

1000

1330

1330

Max. current

A

4.4

4.4

6

6

Model

PG135X1C-4DZ2

PG135X1C-4DZ2

PG180X1C-4DZ3

PG180X1C-4DZ

Type

Rotary

Rotary

Rotary

Rotary

Brand

TOSHIBA

TOSHIBA

TOSHIBA

TOSHIBA

Capacity

Btu/h

8086/8172

8086/8172

10800

10800

Input

W

765/785

765/785

1015

1015

Rated current(RLA)

A

3.52/3.34

3.52/3.34

4.5

4.5

Locked rotor Amp(LRA)

A

Thermal protector

UP3SE0591-T71

UP3SE0591-T71

UP3SE0591-T61

UP3SE0591-T61

Capacitor

uF

25

25

30

30

Compressor

Refrigerant oil

ml

400

400

400

400

Model

RPG13H

RPG13H

RPG13H

RPG13H

Input

W

36.5

37.5

38.5

39.5

Capacitor

uF

1.2

1.2

1.2

1.2

Indoor fan motor

Speed(hi/mi/lo)

r/min

1020/960/900

1020/960/900

1100/1020/950

1100/1020/950

Indoor air flow (Hi/Mi/Lo)

m3/h

430/400/370

430/400/370

470/440/410

470/440/410

Indoor noise level (Hi/Mi/Lo)

dB(A)

35/32/30

35/32/30

36/32/30

36/32/30

Dimension (W*H*D)

mm

1020×315×200

1020×315×200

1190×320×205

1190×320×205

Packing (W*H*D)

mm

1150X395X300

1150X395X300

1265X445X320

1265X445X320

Indoor unit

Net/Gross weight

Kg

8.5/10.5

8.5/10.5

8.5/10.5

8.5/10.5

Model

YDK24-6T

YDK24-6T

YDK25-6C

YDK24-6

Input

W

70

70

85

72

Capacitor

uF

3

3

2.5

2.5

Outdoor fan

motor

Speed

r/min

850

850

900

850

Outdoor air flow

m3/h

1600

1600

1900

1900

Outdoor noise level

dB(A)

49

49

50

50

Dimension(W*H*D)

mm

700X535X235

700X535X235

780X540X250

780X540X250

Packing (W*H*D)

mm

815X580X325

815X580X325

910X575X335

910X575X335

Outdoor unit

Net/Gross weight

Kg

30/33

29/32

36/39

34/37

Refrigerant type R407C

g

740

650

840

770

Design pressure

MPa

2.8

2.8

2.8

2.8

Liquid side/ Gas side

mm(inch

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Ф6.35/Ф9.53

Max. refrigerant pipe length

m

10

10

10

10

Refrigerant

piping

Max. difference in level

m

5

5

5

5

Operation temp

17~30

17~30

17~30

17~30

Ambient temp

-7 ~ 43

-7 ~ 43

-7 ~ 43

-7 ~ 43

Application area

m2

10-14

10-14

14-21

14-21

★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient

condition.


background image

65

Model

MSG-12CRN2

MSG-12HRN2

Power supply

Ph-V-Hz

1, 220-240V~, 50Hz

1, 220-240V~, 50Hz

Capacity

Btu/h

12000

12000

Input

W

1350

1350

Rated current

A

6.0

6.0

Cooling

EER

Btu/w.h

8.9

8.9

Capacity

Btu/h

13500

Input

W

1300

Rated current

A

5.8

Heating

COP

Btu/w.h

10.4

Moisture Removal

L/h

1.2

1.2

Max. input consumption

W

1800

1800

Max. current

A

7.8

7.8

Model

PG225X2C-4FT

PG225X2C-4FT

Type

Rotary

Rotary

Brand

TOSHIBA

TOSHIBA

Capacity

Btu/h

13550/13700

13550/13700

Input

W

1290/1335

1290/1335

Rated current(RLA)

A

6.1

6.1

Locked rotor Amp(LRA)

A

31

31

Thermal protector

UP3RE0591-T56

UP3RE0591-T56

Capacitor

uF

35

35

Compressor

Refrigerant oil

ml

480

480

Model

RPG20D

RPG20D

Input

W

49.2

49.2

Capacitor

uF

1.5

1.5

Indoor fan motor

Speed(hi/mi/lo)

r/min

1060/900/800

1060/900/800

Indoor air flow (Hi/Mi/Lo)

m3/h

580/550/520

580/550/520

Indoor noise level (Hi/Mi/Lo)

dB(A)

36/32/29

36/32/29

Dimension (W*H*D)

mm

815X280X195

815X280X195

Packing (W*H*D)

mm

915X360X275

915X360X275

Indoor unit

Net/Gross weight

Kg

10.5/13.5

10.5/13.5

Model

YDK24-6H

YDK24-6H

Input

W

85

85

Capacitor

uF

2.5

2.5

Outdoor fan motor

Speed

r/min

850

850

Outdoor air flow

m3/h

2100

2100

Outdoor noise level

dB(A)

53

53

Dimension(W*H*D)

mm

780X540X250

780X540X250

Packing (W*H*D)

mm

910X575X335

910X575X335

Outdoor unit

Net/Gross weight

Kg

35/39

36/40

Refrigerant type R407C

g

730

730

Design pressure

MPa

2.8

2.8

Liquid side/ Gas side

mm(inch)

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Max. refrigerant pipe length

m

10

10

Refrigerant piping

Max. difference in level

m

5

5

Plug type

16A

16A

Thermostat type

Electronic control

Electronic control

Operation temp

17-30

17-30

Ambient temp

18-45

-7-45

Application area

m2

18-26

18-26

★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient

condition.

background image

66

Model

MSG-18HRN2

MSG-18CRN2

MSG-21CRN2

MSG-21HRN2

Power supply

Ph-V-Hz

220-240V~,50Hz

220-240V~,50Hz

1, 220-240V~, 50Hz

1, 220-240V~,

Capacity

Btu/h

18000

18000

21000

21000

Input

W

2000

2000

2350

2350

Rated current

A

9.0

9.0

10.7

10.7

Cooling

EER

Btu/w.h

9.0

9.0

8.9

8.9

Capacity

Btu/h

21000

23500

Input

W

2200

2450

Rated current

A

9.8

11.2

Heating

COP

Btu/w.h

9.5

9.6

Moisture Removal

L/h

1.6

1.6

1.9

1.9

Max. input consumption

W

2600

2600

2700

2700

Max. current

A

13.0

13.0

14.0

14.0

Model

PG340X3CS-4KU2

PG340X3CS-4KU2

PG340X3CS-4KU2

PG340X3CS-4KU2

Type

Rotary

Rotary

Rotary

Rotary

Brand

TOSHIBA

TOSHIBA

TOSHIBA

TOSHIBA

Capacity

Btu/h

6100

6100

20800

20800

Input

W

1970

1970

1970

1970

Rated current(RLA)

A

9.2

9.2

9.2

9.2

Thermal protector

UP3SE0391-T09

UP3SE0391-T09

UP3SE0391-T09

UP3SE0391-T09

Capacitor

uF

50

50

50

50

Compressor

Refrigerant oil

ml

850

850

850

850

Model

RPG25

RPG25

RPG25

RPG25

Input

W

53

53

53

53

Capacitor

uF

1.5

1.5

1.5

1.5

Indoor fan motor

Speed(hi/mi/lo)

r/min

1260/1100/1000

1260/1100/1000

1260/1100/1000

1260/1100/1000

Indoor air flow (Hi/Mi/Lo)

m3/h

800/770/740

800/770/740

800/770/740

800/770/740

Indoor noise level (Hi/Mi/Lo)

dB(A)

41/37/35

41/37/35

41/37/35

41/37/35

Dimension (W*H*D)

mm

906X286X235

906X286X235

906X286X235

906X286X235

Packing (W*H*D)

mm

1020X380X328

1020X380X328

1020X380X328

1020X380X328

Indoor unit

Net/Gross weight

Kg

13.5/16.5

13.5/16.5

13.5/16.5

13.5/16.5

Model

YDK53-6KB

YDK53-6KB

YDK53-6KB

YDK53-6KB

Input

W

150

150

150

150

Capacitor

uF

3.0μF/450V

3.0μF/450V

3.0µF/450V

3.0µF/450V

Outdoor fan motor

Speed

r/min

840

840

840

840

Outdoor air flow

m3/h

2300

2300

2300

2300

Outdoor noise level

dB(A)

53

53

53

53

Dimension(W*H*D)

mm

845X695X330

845X695X330

845X695X335

845X695X335

Packing (W*H*D)

mm

970X770X395

970X770X395

970X770X395

970X770X395

Outdoor unit

Net/Gross weight

Kg

55/60

52/57

52/57

55/60

Refrigerant type R407c

g

2100

1700

2100

2100

Design pressure

MPa

2.8

2.8

2.8

2.8

Liquid side/ Gas side

mm(inch)

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Ф6.35/Ф12.7

Max. refrigerant pipe length

m

10

10

15

15

Refrigerant piping

Max. difference in level

m

5

5

8

8

Operation temp

17~30

17~30

17~30

17~ 30

Ambient temp

-7~30

-7~43

-7~43

7~43

Application area

m2

30-40

30-40

34-49

34-49

★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient

condition.

background image

67

3.Dimensions
3.1 Indoor unit
MSG-05/07/09C(H)R(N2),MSG-12C(H)R


3.2 Indoor unit MSG-12C(H)R(N2)

background image

68


3.3 Indoor unit MSG-18/21C(H)R(N2)

3.4 Outdoor unit MSG-05/07C(H)R(N2),

background image

69

3.5 Outdoor unit MSG-12C(H)R




3.6 Outdoor unit MSG-18/21C(H)R(N2)

background image

70

4.Refrigeration cycle diagram

4.1 Cooling/heating

Indoor unit outdoor unit

Valve

Sensor of room temp

. 4 way valve


Heat exchanger Heat exchanger


Sensor of heat exchanger temp

.

Compressor


Valve

Capillary

4.2 Cooling only

Indoor unit outdoor unit


Valve

Sensor of room temp

.


Heat exchanger Heat exchanger


Sensor of heat exchanger temp

.

Compressor


Valve

Capillary

background image

71

5.Operation limits

5.1Cooling operation

Outdoor unit air temp.

℃ DB

45

40

35

30

25

20

10 15 20 25 30 35 40

Indoor air temp.

℃ DB

Note : The chart is the result from the continuous operation under constant air temperature

conditions. However, excludes the initial pull-down stage.

5.2Heating operation

Indoor air temp.

℃ DB

30

25

20

15

10

5

-5 5 15 25

Outdoor unit air temp.

℃ DB

Note : The chart is the result from the continuous operation under constant air

temperature conditions. However, excludes the initial pull-down stage.


DRY COOLING

background image

72

6.Wiring diagram
6.1 Cooling only

6.1.1 MSG-05CR Indoor unit

background image

73


6.1.2 MSG-07CR,MSG-07CRN2, MSG-09CR,MSG-09CRN2

background image

74


6.1.3 MSG-12CR Indoor unit (A Type)

background image

75

6.1.4 MSG-12CR (B Type), MSG-12CR N2

background image

76


6.1.5 MSG-16CR, MSG-18CR ,MSG-21CR, MSG-18CRN2 ,MSG-21CRN2

background image

77

6.2 Heating/cooling

6.2.1 MSG-07HR,MSG-07HRN2,
MSG-07HR,MSG-07HRN2,MSG-09HR,MSG-09HRN2,MSG-12HR

background image

78

6.2.2 MSG-12HR(B TYPE),MSG-12HRN2

background image

79

6.2.3 MSG-16HR,MSG-18HR,MSG-21HR,

MSG-16HRN2,MSG-18HRN2,MSG-21HRN2






background image

80

7.Troubleshooting

7.1 For all cooling only model

Failure phenomenon

Operation lamp

Timer lamp

Indoor fan speed has been out of control for over 1 minute

X

Indoor room temp. or evaporator sensor is open circuit or short

circuit

On

Over current protection of the compressor occurs 4 times

X

EEROM error

On

No over-zero signal

r Extinguish

Flash at 5Hz

7.2 For all heat pump model

Failure phenomenon

Operation lamp

Timer lamp

Defrosting lamp

Over current protection of the compressor occurs 4 times

X

Indoor fan speed has been out of control for over 1 minute

X

No over-zero signal

Temp. sensor on indoor evaporator is open circuit or short circuit

X

X

Indoor room temp. sensor is open circuit or short circuit

X

X

EEROM error

On

X

r Extinguish

☆ Flash at 5Hz

8 Electronic function

8.1

Electric Control working environment

8.1.1

input voltage: 175~253V

8.1.2

Input power frequency:50Hz

8.1.3

Ambient temperature: -7°C~+43°C

8.1.4

Indoor fan normal working amp is less than 1A,

8.1.5

Outdoor fan. Normal working amp is less than 1.5A

8.1.6

Four-way valve normal working amp is less than 1A.

8.1.7

Swing motor: DC12V.

8.1.8

Compressor: single-phase power supply. Its normal working amp is less than 15A

8.2

Proper symbols and their meanings:

TA: Indoor ambient temperature

TE: Indoor evaporator temperature

TS: Setting temperature through the remote controller

I

3sec

: Self-protection amp of compressor, continue three seconds until turns off the compressor.

I

5MIN

: Self-protection amp of compressor, continue five minutes until turns off the compressor.

I

FAN

: Self-protection amp of outdoor fan/indoor fans when they change from higher wind to lower

wind.

I

RESTORE

: Amp self-protection return value

TH

DEFROST

: High wind, defrosting temperature difference

TM

DEFROST

: Middle wind, defrosting temperature difference

TL

DEFROST

: Low wind, defrosting temperature difference

TE1: Anti-cold wind, from Fan Off to Breeze temperature

TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature

background image

81

TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature

TE4: Anti-cold wind, from Breeze to Fan Off temperature

TE5: Evaporator low temperature protection entering temperature

TE6: Evaporator low temperature protection restoring temperature

TE7: Evaporator high temperature protection, compressor off temperature

TE8: Evaporator high temperature protection, fan off temperature

TE9: Evaporator high temperature protection, restoring temperature

8.3

Systematic functions

Remote receiving

Testing and forced run

Position set for indoor unit wind vane

LED displaying and alarm

On or off Timer

Protection for the compressor

Current protection

High temperature protection of indoor heat exchanger at heating mode

Auto defrosting and heating recovery at heating mode

Anti cold air at heating mode

Anti frozen at heating mode

8.4

Protection

8.4.1 The compressor functions protection with a delay of three minutes.

8.4.2 Sensor protection at open circuit and breaking disconnection

8.4.3 Temperature Fuse break protection

8.4.4 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High

Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure

information and can’t returns to normal operation automatically.

8.4.5 Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops

and LED displays failure information and can’t returns to normal operation automatically.

8.4.6 The current protection of the compressor

Condition

Indoor fan

Compressor

Outdoor fan

Remark

I< I

RESTORE

On

On

On

On

On

Off

Heating mode

I

RESTORE

<I< I

FAN

Low speed

On

On

Cooling mode

I

FAN

<I<I

5MIN

Off

Off

After 5 Minutes

Current up

I

5MIN

<I< I

3SEC

Off

Off

After 3 Seconds

I

5MIN

<I< I

3SEC

Off

Off

After 3 Seconds

I

FAN

<I<I

5MIN

Off

Off

After 5 Minutes

On

On

Off

Heating mode

I

RESTORE

<I< I

FAN

Low speed

On

On

Cooling mode

Current down

I< I

RESTORE

On

On

On

If compressor turns off for continuously 4 times due to current protection in 5 minutes from

Compressor On, the unit stops and LED displays failure information and can’t returns to

normal operation automatically.

background image

82

8.5

Fan-only mode

Fan speed is high/mid/low/ Auto

8.6 Cooling mode

The 4-way valve is closed at cooling mode.

The action of the compressor and the outdoor fan:

Condition

Compressor

Outdoor fan

T>Ts+1

On

On

Temp. up

T<Ts+1

Off

Off

T>Ts

On

On

Temp. down

T<Ts

Off

Off

Auto fan at cooling mode:

Condition

T=Indoor Temp.-Setting Temp.

Indoor fan speed

T<3℃

Low

3℃<T<5℃

Med.

Temp. up

T>5℃

High

T>3℃

High

1℃<T<3℃

Med.

Temp. down

T<1℃

Low

Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. )

Condition

Temp.

Time

Compressor

Outdoor fan

T> TE6

On

On

Temp. up

T< TE6

>5 Minutes

Off

Off

T> TE5

On

On

Temp. down

T< TE5

>5 Minutes

Off

Off

8.7

Dehumidifying mode

8.7.1

The 4-way valve is off in dehumidifying mode

8.7.2

Compressor and Indoor Fan actions in dehumidifying mode

NO

Conditions

Indoor Fan

Compressor and Outdoor Fan

1

TA ≥TS+2

LOW

BREEZE

ON 6minutes

OFF 4minutes

2

TS ≤TA<TS+2

LOW

BREEZE

ON 5minutes

OFF 5minutes

3

TA < TS

LOW

BREEZE

ON 4minutes

OFF 6minutes

Repeat on and off cycle.

background image

83

8.7.3

Low room temperature protection:

When room temperature decreases to below 10 ℃ , compressor and outdoor fan will

stop(indoor fan is Breeze). Dehumidifying operation will be resumed when room temperature

restores to over 13℃.

8.7.4

At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same

as that of cooling mode.

8.7.5

At dehumidifying mode, the action of fans of indoor is the same as that of air-only mode.

8.8

Heating mode

8.8.1

Generally, the 4-way valve is open in heating mode, but it is closed in defrosting mode. 4-way

valve must delay 2 minutes compared with compressor if the compressor changed into

non-heating mode or turned off. 4-way valve doesn't delay in dehumidifying mode.

8.8.2

Generally, the outdoor fan is turned off with the on-off action of compressor in heating mode,

except for the defrosting mode or the end of defrost.

8.8.3

Action of compressor and outdoor fan motor at heating mode: compressor must run for 7

minutes after starting and then judge temperature. Meanwhile other protections are still valid.

Condition

Compressor

Outdoor fan

T> Ts+3

Off

Off

Room temp. up

T<Ts+3

On

On

T< Ts+2

On

On

Room temp. down

T>Ts+2

Off

Off

8.8.4

Indoor Fan actions at heating mode

Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold

wind function prevails.

Anti-cold wind control function at heating mode

Condition

T= Indoor exchanger temp.

Indoor fan speed

T<TE1

Off

TE1<T<TE2

Breeze

Indoor exchanger temp. up

T>TE2

Setting fan speed

T> TE3

Setting fan speed

TE3<T<TE4

Breeze

Indoor exchanger temp. down

T<TE4

Off

8.8.5

Auto wind at heating mode

Condition

T=Indoor Temp.-Setting Temp.

Indoor fan speed

T<2℃

High

Room temp. up

T>2℃

Med.

T>0℃

Med.

Room temp. down

T<0℃

High

background image

84

8.8.6

Indoor evaporator high-temperature protection at heating mode

Condition

T= Indoor exchanger temp.

Compressor

Outdoor fan

T<TE8

On

On

TE8<T<TE7

On

Off

Indoor exchanger temp. up

T>TE7

Off

Off

T>TE9

Off

Off

Indoor exchanger temp. down

T<TE9

On

On

8.8.7. The louver opens to Standard Angle ANGLHEAT when power is on for the first time

8.9

Defrosting operation (Available for heating only).

8.9.1

Defrosting condition: Defrosting starts when either of the following ①&②:

① A and B are satisfied:

A: The compressor keeps running for 40 minutes or more.

B: The temperature difference of evaporator and room temperature meets one of the

following:

Temp. of evaporator---room temp.

Fan speed is high

≤TH

DEFROST

Fan speed is mid

≤TM

DEFROST

Fan speed is low

≤TL

DEFROST

Breeze

Meet only if it is Breeze

② Calculate from the end of latest defrost, evaporator high temp. protection only closes outdoor

fan with the compressor still running. Add up to 90 minutes.

8.9.2 Defrosting time

If the temp. difference condition ① is satisfied for less than 40 minutes, this can be regarded

as severe frosting. The defrosting time is 10 minutes.

If the temp. difference condition ② is satisfied for more than 40 minutes, the defrosting time is

6 minutes.

If the temp. difference condition ① is satisfied out of 40 minutes, generally the defrosting time

is 6 minutes, after three continuous 6-minute defrost, the fourth should be 10 minutes defrost.

The circulation is as following:

→6-minute defrost → 6-minute defrost→6-minute defrost→10-minute defrost→


8.9.3 Ending condition of defrosting

If one of following conditions is satisfied, end the defrost and turn into heating mode:

A. The defrost time has reached to 6 or 10 minutes.

B. The compressor current has reached to I

DEFROST

or above, I

DEROST

differs in different

models.

background image

85

8.9.4 Defrosting Actions:

8.9.7 Turn into heating mode, turn off the heating mode in 7 minutes.

8.10

Automatic operation mode

8.10.1

The air conditioner automatically selects one of the following operation modes: cooling,

heating or fan only according to the temp. difference between room temp. (TA) and set temp.

(TS).

TA—TS

Operation mode

TA—TS>2℃

Cooling

-1℃≤TA—TS≤+2℃

Fan-only

TA—TS<-1℃

Heating (air-only for cooling only type)

8.10.2

The indoor fan blows automatically in corresponding selected mode.

8.10.3

The motion of indoor fan’s blade should accord with the selected operation mode.

8.10.4

One mode should be carried out for at least 15 minutes once selected. If the compressor

cannot start for 15 minutes, reselect the operation mode according to the room temp. and set

temp., or reselect when the set temp. varies.

8.11

Forced cooling function

8.11.1

Select forced cooling function with the forced cooling button or the switch.

8.11.2

The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan

mode is set as low, the A/C operates at the DRY mode with a set temp. of 24℃.

8.11.3

All protections of remote control cooling are available at forced cooling operation.

8.12

Forced Auto function

Select forced auto function with the forced auto button or the switch.

In forced auto status the A/C operates at remote control mode with a set temp. of 24℃.

8.13

Timer Function

Defrost 10or 6minutes

45S 25S

Compressor

4-way Valve

23S

40S

Outdoor Fan

Indoor Fan

10S

background image

86

8.14

Economic Running

8.14.1

The economic running function is available at cooling, heating or auto mode.

8.14.2

Cooling:

The set temperature rise 1℃ per hour. Two hours later, the set temperature will maintain as

a constant and the fan speed is kept at low speed.

8.14.3

Heating:

The set temperature decrease 1℃ per hour. Two hours later, the set temperature will

maintain as a constant and the air circulation is kept at low speed (Cold air proof function

takes precedence over all).

8.14.4

Auto:

The economic running function operates in accordance with selected running mode by auto

mode.

8.15

Auto restart function

In case of a sudden power failure, this function automatically sets the unit to previous settings

before the power failure when power returns.

background image

87

8.16

Models and Parameters

Model

MSG-07CR

MSG-07HR

MSG-09CR

MSG-09HR

MSG-12CR

MSG-12HR

I3SEC

8.5A

8.5A

10.0A

10.0A

11.0A

11.0A

I5MIN

6.2A

6.2A

7.5A

7.5A

10.0A

10.0A

IFAN

5.2A

5.2A

5.5A

5.5A

8.0A

8.0A

IRESTORE

4.2A

4.2A

4.5A

4.5A

6.0A

6.0A

IDEFROST

3.2A

3.5A

5.5A

TE1

28℃

28℃

28℃

TE2

32℃

32℃

32℃

TE3

30℃

30℃

30℃

TE4

26℃

26℃

20℃

TE5

2℃

2℃

2℃

2℃

3℃

3℃

TE6

7℃

7℃

7℃

7℃

8℃

8℃

TE7

60℃

60℃

60℃

TE8

53℃

53℃

53℃

TE9

50℃

50℃

50℃

ANGLCOOL

200°

200°

200°

200°

200°

200°

ANGLHEAT

ANGLOFF

124°

124°

124°

124°

124°

124°

TH

DEFROST

16℃

14℃

14℃

TM

DEFROST

17℃

15℃

15℃

TL

DEFROST

18℃

16℃

16℃

background image

88

Model

MSG-07CRN2

MSG-07HRN2

MSG-09CRN2

MSG-09HRN2

I3SEC

8.5A

8.5A

10.0A

10.0A

I5MIN

6.2A

6.2A

7.5A

7.5A

IFAN

5.2A

5.2A

5.5A

5.5A

IRESTORE

4.2A

4.2A

4.5A

4.5A

IDEFROST

3.2A

3.5A

TE1

28℃

28℃

TE2

32℃

32℃

TE3

30℃

30℃

TE4

26℃

26℃

TE5

4℃

4℃

4℃

4℃

TE6

10℃

10℃

10℃

10℃

TE7

60℃

60℃

TE8

53℃

53℃

TE9

50℃

50℃

ANGLCOOL

200°

200°

200°

200°

ANGLHEAT

ANGLOFF

124°

124°

124°

124°

TH

DEFROST

14℃

14℃

TM

DEFROST

15℃

15℃

TL

DEFROST

16℃

16℃

background image

89

Model

MSG-12CR
(B type)

MSG-12HR*

(B type)

MSG-16CR

MSG-16HR

MSG-18CR
MSG-21CR

MSG-18HR
MSG-21HR

MSG-12CRN2

MSG-12HRN2

MSG-18CRN2

MSG-18HRN2

I3SEC

14.5A

14.5A

16.0A

16.0A

17.0A

17.0A

I5MIN

13.5A

13.5A

13.0A

13.0A

16.0A

16.0A

IFAN

9.5A

9.5A

11.0A

11.0A

14.0A

14.0A

IRESTORE

8.5A

8.5A

9.5A

9.5A

12A

12A

IDEFROST

6.5A

6.5A

7A

TE1

34℃

34℃

34℃

TE2

37℃

36℃

36℃

TE3

33℃

30℃

30℃

TE4

22℃

20℃

20℃

TE5

2℃

2℃

3℃

3℃

3℃

3℃

TE6

7℃

7℃

10℃

10℃

10℃

10℃

TE7

62℃

60℃

64℃

TE8

56℃

52℃

56℃

TE9

50℃

50℃

50℃

ANGLCOOL

40°

40°

50°

50°

50°

50°

ANGLHEAT

197°

105°

105°

ANGLOFF

100°

100°

TH

DEFROST

17℃

17℃

20℃

TM

DEFROST

18℃

18℃

21℃

TL

DEFROST

19℃

19℃

22℃


Wyszukiwarka

Podobne podstrony:
DTR GLORY ECO MSG21 24HRN2
DTR GLORY MULTI MS3G30HRN2
04 Eco U Jak napisac prace dyplomowa Redakcja tekstu Adresat
DTR KWSOI 40
KGE 750F dtr
IT3SCA a DTR
Do higieny intymnej, ECO kosmetyki
eco-sciaga, wains knsia 07-09, Ekonomia
DTR.PR...01-Ex, Instrukcje, aplisens, dtr
CMC 3MS DTR
Field of Glory Errata
eco żyto
Naturalny środek odstraszający owady, ECO kosmetyki
DTR daikin

więcej podobnych podstron