4. Dobór grzejników | ||||||||
Nazwa i nr pomieszczenia | Q | ti [C] | Bo | Bu | Qgrzejnika | dobrany grzejnik | Q [kkcal/h] | |
1 Salon | 2847,718 | 20 | 1 | 1 | 2449 | 4*KA-300/7 | 2449,03748 | 0,86 |
2 Kuchnia + Jadalnia | 1697,822 | 20 | 1 | 1 | 1460 | 3*KA-300/6 | 1460,12692 | |
3 Hol | 721,1536 | 20 | 1 | 1,25 | 775 | 2*KA-300/5 | 620,192096 | |
4 WC | 802,7069 | 24 | 1 | 1 | 690 | KA-300/9 | 690,327934 | |
5 Łazienka | 1279,608 | 24 | 1 | 1 | 1100 | KA-300/14 | 1100,46288 | |
6 Wiatrołap | 238,68 | 16 | 1 | 1,25 | 257 | KA-300/3 | 205,2648 | |
101 Sypialnia | 1312,386 | 20 | 1 | 1 | 1129 | 2*KA-300/6 | 1128,65196 | |
102 Sypialnia | 1234,309 | 20 | 1 | 1 | 1062 | 2*KA-300/6 | 1061,50574 | |
103 Hol | 1240,103 | 20 | 1 | 1,25 | 1333 | 3*KA-300/5 | 1066,48858 | |
104 Łazienka | 891,2899 | 24 | 1 | 1 | 766 | KA-300/9 | 766,509314 | |
105 Pokój | 1592,554 | 20 | 1 | 1 | 1370 | 3*KA-300/5 | 1369,59644 | |
106 Garderoba | 255,2711 | 20 | 1 | 1 | 220 | KA-300/3 | 219,533146 |