MR293R190_611
AIR CONDITIONING
Fault finding - Fault charts
FAULT CHART N° 10 : Controls difficult to operate
Check the cable path: stop the cable catching,
kinking or rubbing on collars etc, ...
Change the cable if necessary.
Does the fault persist?
yes
Correct
no
If the controls are very difficult to operate, inform
your local After Sales Head Office (For UK, contact
the Technical Services Department).
Unhook the cable from the control panel or the
assembly and check the operation of the control
knob and the flap (mixing or distribution).
Is this correct?
no
Change the control panel or the heating /
ventilation assembly.
(If the flap is difficult to operate).
yes
e53531.1