TheDCSFamilyisideallysuitedforawiderangeofapplicationsrequiringDCpower
inasmallformfactor.Applicationsrangefrommanufacturingtestandburn-inof
automotivecomponents,avionicselectronics,telecommunicationsandconsumers
productstobeamsteering,processcontrolandlaboratoryR&Duse.

TheDCSFamilyiscomprisedof1KW,1.2KWand3KWprogrammablepowersupplies
utilizing switchmode technology to achieve high power density in a low profile
chassis.Thedesignplatformprovidesahighlyreliablepowersupplyforyearsof
constantuse.Theuniquedesignisavailableinavarietyofmaximumvoltagesfrom
8Vto600Vandmaximumcurrentsfrom2Ato350Awithlowrippleandnoise.

Thisuser-friendlyplatformcanbecontrolledformthefrontpanelwith10-turn
potentiometerstoadjustvoltage,currentandOVPsettings.LEDsindicate
overtemperature,remoteprogramming,shutdownandovervoltageprotection

RemotecontroloptionsallowfullcomputercontrolthroughIEEE-488(optionM9C),LXI
StandardCompliant*EthernetLAN(optionM130)orRS-232(M9C,M130,M131)

DCS Series: 1 kW, 1.2 kW, & 3 kW

Automotive Component Test
The16-bitresolutionoftheEthernet
programmingandhardwaretriggeringallows
fordetailedsequencingassociatedwithbattery
fluctuation simulation. The tight load regulation
capabilityoftheDCSseriesmakesitasuperior
sourceforvalidationandacceptancetesting
andburn-inofautomotivecomponents.The
20Vmodels,inparticular,provideafullrangeof
testingtosimulatebatteryconditions.Margin
testingof12Vand14Vnominalcomponents,
suchaselectroniccontrolunits(ECU)and
electromechanicalcomponents,iseasily
achieved

Rackmount ATE Systems
ThehighpowerdensityoftheDCsseries
makesitidealforATESystemintegration.
Thewidevarietyofvoltageandcurrent
combinationsin1Uand2Uheightsallows
multiplevoltageoutputsinasmallamountof
space.Thewidevarietyofcontrolmethods
possibleallowseasyintegrationintolegacy
systemsaswellashighspeedsystems.

Battery Charging
Batterychargingrequireshighaccuracyvoltage
andstablecurrentoutputforfastbulkand
absorptionphasechargingandhighaccuracy
and stable voltage for float charging to avoid
“gassing”thebattery.TheDCSseriesprovides
ahighaccuracyvoltageoutputtooptimize
batterycharging.Withtheremoteinterface
options,thechargingprocesscaneasilybe
automatedforvolumeproduction.

* http://www.lxistandard.org

•WideSelectionofOutputVoltages

Voltagerangesfrom0-8VDCto0-600
VDC;currentlevelsfrom1.7Ato350A

•HighPowerDensity

•1kWor1.2kWofpowerina

packageonly1.75incheshigh

•3kWofpowerinapackageonly

3.5incheshigh

•Improvedprogrammingresolutionwith

Ethernetinterface

•16bitcontrol
•0.002%programmingandreadback

resolution

•TightRegulation

•Lineregulation:0.1%
•Loadregulation:0.1%

•FlexibleRemoteProgrammingOptions

•Ethernet/RS-232
•GPIBIEEE-488/RS-232
•Analog:Selectableremote

programmingforvoltage,current
andOVP.Optionalisolatedanalog
programming

•Software

• LabVIEW®driverforGPIB
• IVI-comdriverforEthernet

•5YearWarranty

background image

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

E L G A R E L E C T R O N I C S C O R P O R A T I O N

DCS Series

Output
Voltage and Current

1 kW Model

Voltage

Current

DCS8-125E

0-8

0-125

DCS10-100E

0-10

0-100

DCS20-50E

0-20

0-50

DCS33-33E

0-33

0-33

DCS40-25E

0-40

0-25

DCS50-20E

0-50

0-20

DCS60-18E

0-60

0-18

DCS80-13E

0-80

0-13

DCS100-10E

0-100

0-10

DCS150-7E

0-150

0-7

DCS300-3.5E

0-300

0-3.5

DCS600-1.7E

0-600

0-1.7

1.2 kW Model Voltage

Current

DCS8-140E

0-8

0-140

DCS10-120E

0-10

0-120

DCS20-60E

0-20

0-60

DCS33-36E

0-30

0-36

DCS40-30E

0-40

0-30

DCS50-24E

0-50

0-24

DCS60-20E

0-60

0-20

DCS80-15E

0-80

0-15

DCS100-12E

0-100

0-12

DCS150-8E

0-150

0-8

DCS300-4E

0-300

0-4

3 kW Model

Voltage

Current

DCS8-350E

0-8

0-350

DCS12-250E

0-12

0-250

DCS20-150E

0-20

0-150

DCS40-75E

0-40

0-75

DCS55-55E

0-55

0-55

DCS60-50E

0-60

0-50

DCS80-37E

0-80

0-37

DCS150-20E

0-150

0-20

Voltage Resolution:0.02%
Ripple (mV RMS or P-P):Seetable
Regulation (Line or Load)
Voltage:
0.1%
Current:0.1%
Transient Response:Typicallyrecoversin500µs
(1&1.2kW)or1ms(3kW)to1%ofsteady-state
outputvoltage(within1%ofVmax)for70-100%or
100-70%loadchange.
Stability:±0.05%ofmaximumvoltageorcurrent
over8hoursafter30minutewarm-uptimeat
fixed line, load and temperature
Efficiency:Seetable
Temperature Coefficient:0.02%/°Cofmaximum
outputvoltage;0.03%/°Cofmaximumoutput
current

Input

Voltage and Frequency
1 kW:
200-250VAC,singlephase,8Atypical,
47-63Hz;or100-132VAC,singlephase,15A
typical,47-63Hz,internaljumperselectable(see
M1option)
1.2 kW: 200-250VAC,singlephase,9Atypical,
47-63Hz;or100-132VAC,singlephase,18A
typical,47-63Hz,internaljumperselectable(see
M1option)
3 kW:190-250VAC,threephase,14A
typical,47-63Hz;or200-250VAC,singlephase,
20Atypical,47-63Hz
Note:Maximumpoweroutputof3kWsupplies
mustbelimitedto2.5kWforsinglephaseinput
Soft Start:Linecurrentislowerthanfullload
peakvalueduringturn-onorpowerapplication
afterrestart

General

Operating Temperature:0°Cto50°C(no
derating)
Storage Temperature:-55°Cto85°C
Humidity Range:0to80%RH,
noncondensing
Meter Accuracy:1%offullscale+1count
Max. Voltage Differential from Output to Safety
Ground:
150VDC
Remote Start/Stop and Interlock:TTL
compatibleinputor12-250VAC
(12-130VDC)oracontactclosure
Cooling:Internalfan,overtemperatureshutdown
ifinternalheatsinkexceeedssettemperature
Remote Sense: Themaximumallowedsense
linedropis4Vperline(2VontheDCS8and10V
1kWand1.2kWmodelsand1V/lineforall3kw
models)
Remote Programming:Externaljumperviarear
panelconnectorJ3
Overvoltage Protection:Crowbartypeadjustable
from5-110%ofratedoutputusingfrontpanel
control(localorremoteprogramselectableviaJ3
jumper)
Remote Analog Programming Linearity:±1%
Accuracy:±5%
Regulatory Compliance:CEMark(1,1.2,3kW);
FCCPart15ClassA,UL1012,CSA22.2#220(1
and1.2kWonly)

Dimensions

1 kW and 1.2 kW:1Uor1.75”
(44mm)Hx19”(482mm)Wx17.5”(444mm)D
3 kW:2Uor3.5”(88mm)Hx
19”(482mm)Wx17.5”
(444mm)D

Weight

1 kW and 1.2 kW:19lbs.(8.6kg)
3 kW:33lbs.(15kg)
Shipping Weight
1 kW and 1.2 kW:
24lbs.(10.9kg)
3 kW:42lbs.(19kg)

Options & Accessories

M1: Factory configured for 115 VAC input (1 kW
and1.2kWunitsonly)
M9C:InternalIEEE-488/RS-232Interface(can
onlysupport12-bitslaves)
M13:Lockingshafts(frontpanel
potentiometers)
M32: Master/slave paralleling cable configured for
twounits
M33:Replaceinputconnectorwithterminalblock
(3kWonly)
M51A:Isolatedanalogprogrammingcontrolof
V/I/OVPandisolatedV/Imonitoroutputsupto
500Vrelativetothesupply’sreturnline
M85:12-bitslaveinterfaceoptionforusewithM9
orM130master(3ft.controlcableincluded)
M102:Frontpanelbindingpostsfor1kwor
1.2kw, Models ≤30A, ≤100V. Not compatible
withM9C,M85,M130,M131,M133,M135,
M136
M130:LXIcompliant10/100BaseTEthernet
remotecontrolmasterinterface;includesweb
serverfordirectcontrolofpowersupplyviaweb
browser
M131:16-bitslaveinterfaceoptionforusewitha
M130master(3ft.controlcableincluded)
M133:Outputdisconnectandpolarityreversal
controlledviaSCPIcommands.Limitedto1kor
1.2 kw, ≤100V, ≤60A
M135:M130&M133combination
M136:M131&M133combination

Software

IVI-ComandLabviewdriversavailableforfree
downloadathttp://www.elgar.com/support/
downloads.htm

background image

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Model

Constant Current Mode*

Temp.

Coeff.

%/°C

(Typ.)

Current

Drift

%I0 Max.

(Typ.)

Programming Con-

stants, Current Mode

Input Current, A

Nominal

Efficiency

%

(Typ.)

Regulation

Line and

Load%

Combined

Ripple

(RMS)**

mA

Ohms/A

V/A

230V

Single

Phase

208V

Three

Phase

DCS Series: 1KW

DCS8-125E

0.2

160

0.03

0.05

40

0-10V=

0-100%I

o

or

0-5V=

0-100%I

o

8

N/A

82

DCS10-100E

0.2

128

0.03

0.05

50

8

N/A

82

DCS20-50E

0.2

25

0.03

0.05

100

8

N/A

82

DCS33-33E

0.2

10

0.03

0.05

151.5

8

N/A

84

DCS40-25E

0.2

7

0.03

0.05

200

8

N/A

84

DCS50-20E

0.2

7

0.03

0.05

250

8

N/A

84

DCS60-18E

0.2

6

0.03

0.05

277.8

8

N/A

86

DCS80-13E

0.2

4

0.03

0.05

384.6

8

N/A

86

DCS100-10E

0.2

3

0.03

0.05

500

8

N/A

86

DCS150-7E

0.2

2

0.03

0.05

714.3

8

N/A

86

DCS300-3.5E

0.2

1

0.03

0.05

1428.6

8

N/A

86

DCS600-1.7E

0.2

1

0.03

0.05

2941.2

9.5

N/A

86

DCS Series: 1.2 kW

DCS8-140E

0.2

180

0.03

0.05

35.7

0-10V=

0-100%I

o

or

0-5V=

0-100%I

o

9

N/A

82

DCS10-120E

0.2

153

0.03

0.05

41.7

9

N/A

82

DCS20-60E

0.2

30

0.03

0.05

83.3

9

N/A

82

DCS33-36E

0.2

11

0.03

0.05

138.9

9

N/A

84

DCS40-30E

0.2

9

0.03

0.05

166.7

9

N/A

84

DCS50-24E

0.2

8.5

0.03

0.05

208.3

9

N/A

84

DCS60-20E

0.2

6.6

0.03

0.05

250.0

9

N/A

85

DCS80-15E

0.2

6

0.03

0.05

333.3

9

N/A

85

DCS100-12E

0.2

3.6

0.03

0.05

416.7

9

N/A

85

DCS150-8E

0.2

2.3

0.03

0.05

625.0

9

N/A

85

DCS300-4E

0.2

1.2

0.03

0.05

1250.0

9

N/A

85

DCS Series: 3 kW

DCS8-350E

0.2

870

0.03

0.05

14.3

0-10V=

0-100%I

o

or

0-5V=

0-100%I

o

24

13

82

DCS12-250E

0.2

400

0.03

0.05

20

26

14

82

DCS20-150E

0.2

100

0.03

0.05

33.3

26

14

82

DCS40-75E

0.2

75

0.03

0.05

66.7

26

14

86

DCS55-55E

0.2

40

0.03

0.05

90.9

26

14

82

DCS60-50E

0.2

33

0.03

0.05

100

26

14

86

DCS80-37E

0.2

20

0.03

0.05

135

26

14

86

DCS150-20E

0.2

10

0.03

0.05

250

26

14

86

*Typicalresolutionis0.02%**RMSrippletypicalfrom20Hzto300kHz***Consultfactory

background image

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Model

Output Power

Combined

Regula-

tion

Line and

Load %

Constant Voltage Mode*

Temp.

Coeff.

Voltage%

/°C (Typ)

Voltage

Drift%

Vmax

(Typ)

Programming Con-

stants Voltage Mode

Voltage

VDC

Current

ADC@ 50°C

Ripple

Noise

(P-P)

Transient

Response

Time µs

(Typ)

Ohms/

V

V/V

DCS Series: 1KW

DCS8-125E

0-8

0-125

0.2

4mV

60mV

500

0.02

0.05

625

0-10V=

0-100%V

o

or

0-5V=

0-100%V

o

DCS10-100E

0-10

0-100

0.2

4mV

60mV

500

0.02

0.05

500

DCS20-50E

0-20

0-50

0.2

4mV

60mV

500

0.02

0.05

250

DCS33-33E

0-33

0-33

0.2

4mV

60mV

500

0.02

0.05

151.5

DCS40-25E

0-40

0-25

0.2

4mV

60mV

500

0.02

0.05

125

DCS50-20E

0-50

0-20

0.2

4mV

60mV

500

0.02

0.05

100

DCS60-18E

0-60

0-18

0.2

4mV

60mV

500

0.02

0.05

83

DCS80-13E

0-80

0-13

0.2

4mV

60mV

500

0.02

0.05

62.5

DCS100-10E

0-100

0-10

0.2

6mV

60mV

500

0.02

0.05

50

DCS150-7E

0-150

0-7

0.2

12mV

160mV

500

0.02

0.05

33.3

DCS300-3.5E

0-300

0-3.5

0.2

20mV

200mV

500

0.02

0.05

16.67

DCS600-1.7E

0-600

0-1.7

0.2

50mV

300mV

500

0.02

0.05

8.33

DCS Series: 1.2 kW

DCS8-140E

0-8

0-140

0.2

5mV

60mV

500

0.02

0.05

625

0-10V=

0-100%V

o

or

0-5V=

0-100%V

o

DCS10-120E

0-10

0-120

0.2

5mV

60mV

500

0.02

0.05

500

DCS20-60E

0-20

0-60

0.2

5mV

60mV

500

0.02

0.05

250

DCS33-36E

0-33

0-36

0.2

5mV

60mV

500

0.02

0.05

151.5

DCS40-30E

0-40

0-30

0.2

5mV

60mV

500

0.02

0.05

125

DCS50-24E

0-50

0-24

0.2

5mV

60mV

500

0.02

0.05

100

DCS60-20E

0-60

0-20

0.2

5mV

60mV

500

0.02

0.05

83

DCS80-15E

0-80

0-15

0.2

5mV

60mV

500

0.02

0.05

62.5

DCS100-12E

0-100

0-12

0.2

10mV

60mV

500

0.02

0.05

50

DCS150-8E

0-150

0-8

0.2

15mV

160mV

500

0.02

0.05

33.3

DCS300-4E

0-300

0-4

0.2

25mV

200mV

500

0.02

0.05

16.67

DCS Series: 3 kW

DCS8-350E

0-8

0-350

0.2

15mV

100mV

1000

0.02

0.05

625

0-10V=

0-100%V

o

or

0-5V=

0-100%V

o

DCS12-250E

0-12

0-250

0.2

10mV

100mV

1000

0.02

0.05

416.7

DCS20-150E

0-20

0-150

0.2

10mV

100mV

1000

0.02

0.05

250

DCS40-75E

0-40

0-75

0.2

20mV

100mV

1000

0.02

0.05

125

DCS55-55E

0-55

0-55

0.2

20mV

100mV

1000

0.02

0.05

90.9

DCS60-50E

0-60

0-50

0.2

20mV

100mV

1000

0.02

0.05

83

DCS80-37E

0-80

0-37

0.2

20mV

100mV

1000

0.02

0.05

62.5

DCS150-20E

0-150

0-20

0.2

30mV

200mV

1000

0.02

0.05

33.3

*Typicalresolutionis0.02%**RMSrippletypicalfrom20Hzto300kHz***Consultfactory

background image

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Model

Programming Accuracy

Readback Accuracy

M130/M131/M9C Options

Voltage

0.1% +

Current

0.1% +

OVP

0.5% +

Voltage

0.1% +

Current

0.1 +

DCS Series: 1KW

DCS8-125E

8mV

500mA

44mV

12mV

500mA

DCS10-100E

10mV

400mA

55mV

15mV

400mA

DCS20-50E

20mV

200mA

110mV

30mV

200mA

DCS33-33E

33mV

132mA

182mV

50mV

132mA

DCS40-25E

40mV

100mA

220mV

60mV

100mA

DCS50-20E

50mV

80mA

275mV

75mV

80mA

DCS60-18E

60mV

72mA

330mV

90mV

72mA

DCS80-13E

80mV

52mA

440mV

120mV

52mA

DCS100-10E

100mV

40mA

550mV

150mV

40mA

DCS150-7E

150mV

28mA

825mV

225mV

28mA

DCS300-3.5E

300mV

14mA

1650mV

450mV

14mA

DCS600-1.7E

600mV

6.8mA

3300mV

900mV

7mA

DCS Series: 1.2 kW

DCS8-140E

8mV

560mA

44mV

12mV

560mA

DCS10-120E

10mV

480mA

55mV

15mV

480mA

DCS20-60E

20mV

240mA

110mV

30mV

240mA

DCS33-36E

33mV

144mA

182mV

50mV

144mA

DCS40-30E

40mV

120mA

220mV

60mV

120mA

DCS50-24E

50mV

96mA

275mV

75mV

96mA

DCS60-20E

60mV

80mA

330mV

90mV

80mA

DCS80-15E

80mV

60mA

440mV

120mV

60mA

DCS100-12E

100mV

48mA

550mV

150mV

48mA

DCS150-8E

150mV

32mA

825mV

225mV

32mA

DCS300-4E

300mV

16mA

1650mV

450mV

16mA

DCS Series: 3 kW

DCS8-350E

8mV

1400mA

44mV

12mV

1400mA

DCS12-250E

12mV

1000mA

66mV

18mV

1000mA

DCS20-150E

20mV

600mA

110mV

30mV

600mA

DCS40-75E

40mV

300mA

220mV

60mV

300mA

DCS55-55E

55mV

220mA

303mV

83mV

220mA

DCS60-50E

60mV

200mA

330mV

90mV

200mA

DCS80-37E

80mV

148mA

440mV

120mV

148mA

DCS150-20E

150mV

80mA

825mV

225mV

80mA

background image

E L G A R E L E C T R O N I C S C O R P O R A T I O N

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

Tel:858-450-0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•sales@elgar.com•www.elgar.com

E L G A R E L E C T R O N I C S C O R P O R A T I O N

1.10

17.52

(28)

(445)

1.00

(25)

Top View

1.25

19.00

1.72

(482)

(32)

(43)

Front View

Dimensions in inches (millimeters)

16.90

(429)

Options &

Rear View

1KW and 1.2KW

1.10

17.52

1.00

(28)

(445)

(25)

Top View

3.00

19.00

3.46

(482)

(76)

(87)

Front View

16.90

(429)

Rear View

3KW

J3ProgramandSense
1

90-250VACRemoteShutdown 14

TTLShutdown

2

ShutdownReturn

15

+12VDC

3

OVPProgram

16

1mACurrentSource(OVP)

4

Remote/LocalStatusIndicator

17

OVPIndicator

5

ModeStatusIndicator

18

ThermalS/DNStatus

6

Ground

19

0-5VVoltageMonitor

7

0-5VCurrentMonitor

20

RemoteVoltageSelect

8

VoltageControl

21

1mACurrentSource(V)

9

VoltageProgramInput

22

1mACurrentSource(I)

10 CurrentProgramUnit

23

RemoteCurrentSelect

11 CurrentControl

24

Return

12 ReturnSense

25

POSOutput(8-100VModelsOnly)

13 POSSense(8-100VModelsOnly)

InputVoltageOptions
M1

Factory configured for 115 VAC input (1 and 1.2 kW only)

RemoteInterfaceOptions
M9C

InternalIEEE-488/RS232interface

(Supportsonly12-bitslaves)

M13

Lockingshafts(frontpanelpotentiometers)

M32

Master/slave cable configured for two or more units

M33

Replaceinputconnectorwithterminalblock(3kWonly)

M51A

Isolatedanalogprogrammingcontrol

M102

Front Panel Binding Posts (1KW and 1.2KW only≤30A)

M85

12-bitslaveinterface

M130

Ethernet/RS232Interface

(Supportsboth12-&16-bitslaves)

M131

16-bitslaveinterface

M133

Outputdisconnectandpolarityreversalrelays*

M135

Outputdisconnectandpolarityreversalrelays**

M136

Outputdisconnectandpolarityreversalrelays***

105-330-26 Rackslidekit(3kWonly)

* Requires M9C ** Includes option M130 ***Includes option M131

1 and 1.2 kW only

background image

PrintedinUSA0206

DCSSeriesDatasheet

0110002-03


Wyszukiwarka

Podobne podstrony:
DCS
Lista H - obróbka pomiarów DCS, LISTA H - pomiary DCS, Zadanie 301
DCS 2120
B12 Funkcjonalno systemów DCS
DCS 1100
dcs p8i
DCS Expenses Claim Form
DCS 2102
DCS Black Shark Key Commands
06 DCS E
dcs 2100g
DCS Verdi Lascala Delius Verona
DCS C E
PIONEER DCS 100
Pioneer DCS 333

więcej podobnych podstron