Cabling Carnival
For a computer-related technology, Ethernet is pretty long in the
tooth. This means that there are a bunch of ways of configuring its
cabling that are possible that aren't necessarily desirable as you
traverse the next millennium. The good news is that none of the 100Mb
stuff is configurable in any of these old, horrible ways, but if
you're running 10Mb Ethernet, you might be stuck with older cabling
configurations.
______________________________________________________________
It will save you time and money in the long run to replace any of
the following network types. They are obsolete and can be replaced
fairly cheaply. Here's what needs to get thrown in the trash:
Name Connector Type Problems
Thinnet BNC (Coaxial) 10Base-2 Bus cabling means that one disconnected
workstation or cable break takes down the entire segment. It's trouble
prone in general and hard to work with versus modern 10Base-T.
Thicknet BNC (Coaxial) 10Base-5 Bus cabling. It's expensive, trouble
prone, and hard to find parts for.
AUI DB-15 Expensive and hard to find parts for.
All of these bad old network types came before the advent of the
UTP technologies (10Base-T, and later, 100Base-T).
______________________________________________________________
______________________________________________________________
The Base in Base-T refers to the fact that Ethernet is a
baseband-rather than broadband-technology. This is just a geeky
term that refers to its method of signal encoding. The T simply
stands for twisted pair.
______________________________________________________________
People tend to refer to the modern way of connecting Ethernet as
either UTP or 10Base-T. The important part, nowadays, is whether
you're running CAT-V (100Mb) or CAT-III (10Mb). Again, the CAT
designation is simply an industry-standard way of referring to the
manufacturing specifications of the cable. CAT-V can hold a lot more
signal than CAT-III; therefore, you can run 10Mb Ethernet on CAT-V
wiring, but you cannot run 100Mb Ethernet on CAT-III. If you're trying
to run 100Mb Ethernet on CAT-III wiring, you're going to run into
problems.
______________________________________________________________
Don't try running 100Mb Ethernet on wiring that's not certified as
CAT-V. The world may not come to an end, but it still will be bad.
All sorts of intermittent network errors can occur, which can
domino into your applications. What's more, because you're getting
a signal and are talking to the network, you might not realize that
the problem is due to wiring until you've run around looking at
everything else.
______________________________________________________________
Other than that, 100Mb Ethernet is pretty much the same as 10Mb
Ethernet, but faster. For example, the maximum cable run for either
one is 100 meters (330 feet). Both use RJ-45 connectors, and both
require a hub or a switch.
How do you know whether your cable is CAT-V? Well, if it has been
installed any time from 1997 on, you can guess that it's probably
CAT-V. The only way you know is to ask your installer, or to have him
or her test it with a cable scanner. I'll talk briefly about cable
scanners in Hour 21, "Tell Me About Your Network: Network Analyzers &
Bits & Bytes."
______________________________________________________________
A cable plant fails CAT-V certification in at least five ways, so
you should ask the installer to "certify" it as part of the
installation process. This means that he or she will install using
plugs, jacks, cabling, and techniques that are CAT-V compliant and
will actually put a meter on the end-to-end product to ensure that
theory has become practice.
Also, some folks prefer to use certified cable installers-that is,
professional network cable installers with a networking industry
affiliation-rather than an electrician, who might be more
comfortable with A/C power cabling than network cables.
______________________________________________________________
All UTP Ethernet uses four wires: pins 1, 2, 3, and 6. Do you have to
know this to troubleshoot? Only if you want to "tone out" the cable,
as illustrated in Hour 8, "Hard Basics: Guide to Being a Hardware
Geek." In other words, if pins 4, 5, 7, and 8 have problems, it's not
a big deal.
______________________________________________________________
Only NIC-to-hub cables should be straight through-that is, pin to
pin. Cables that are used to connect hubs together should be
crossover. If you have a multimeter, you might want to experiment
to find out which pin on one side of the cable goes to which pin on
the other side. Remember, you can do this by putting the meter in
continuity mode, placing one test lead on pin 1 on one end of the
cable, and then walking your other test lead down each pin of the
other end of the cable.
______________________________________________________________
UTP Ethernet cables have four pairs of twisted wires. Pins 1 and 2
need to be from the same pair, and pins 3 and 6 need to be from the
same pair (see Figure 9.2). Although the intuitive way to make a cable
might be to put pins 1 and 2 together, then 3 and 4, 5 and 6, and 7
and 8, this is not correct. 10Mb Ethernet will run on this, but you
might encounter strange problems under 100Mb. If you see a cable that
looks like it was crimped the wrong way, you might want to exchange
the cable with a known good one.
[09-02t.jpg]
Figure 9.2 Correct Ethernet wire and pin configuration.
Does it sound like the installation really, really matters with
Ethernet? Go to the head of the class! Even jumper cables add to the
overall cable plant of a segment (cable plant is the term often used
to refer to collective cabling). A segment, because it's a party line,
is as strong as the weakest link-one bad apple can spoil a whole
bunch. Again, you'll probably want to use premade cables rather than
manufacturing your own.
Previous Table of Contents Next
Wyszukiwarka
Podobne podstrony:
Programmed repair Auxiliary heater Part C Models 124, 126 020450409 Troubleshooting information Models 124, 126, 201 with auxiliary heating BBW?W 460410 Function test Auxiliary heating BBW?W 46 Models 124, 126, 201124 126Programmed repair Auxiliary heater Part B Models 124, 1260400 Function description auxiliary heater A General Models 124, 126, 2010400 Function description B Operating principle with function diagram Auxiliary heater Models 12126@7 pol ed02 2005 action=produkty wyswietl&todo=koszyk&produkt=126&key=124 10 (3)rozdzial (126)NOWE PRAWO z 29 czerwca 11 (nr 124)więcej podobnych podstron