Values are entered in this manner.
After entering the values the values for a and c as well as whether the top steel yielded are then displayed.
By pressing enter the Nominal Moment capacity for the section is then given. The factored load is also given in foot pounds.
These screen shots are from the second trial of the program.
This is when the tension steel equals 5 in squared.
These are the values for a and c as well as stating that the top steel yielded.
These are the Nominal Moment values for the second trial.