TRANSMISSION AND CRANKSHAFT 10-7
• Measure the crankshaft runout with V-blocks and dial gauge.
IB Crankshaft runout
Service Limit: 0.05 mm (0.002 in)
|S] 09900-20606: Dial gauge (1/100 mm)
09900-20701: Mag net ic stand 09900-21304: V-block
• Measure the crankshaft web to web width with a vernier cali-pers.
Ifflaja Width between webs
Standard: 53.9-54.1 mm (2.122-2.130 in)
|S) 09900-20101: Vernier calipers
• Inspect each oil seal lip for wear and
• Remove the oil seal with the special tool.
IfooJ 09913-50121: Oil seal remover