TRANSMISSION AND CRANKSHAFT 10-7
TRANSMISSION AND CRANKSHAFT 10-7
ieru
♦ Measure the crankshaft runout with V-blocks and dial gauge.
B Crankshaft runout
Service Limit: 0.05 mm (0.002 in)
09900-20606: Dial gauge (1/100 mm) 09900-20701: Magnetic stand
09900-21304: V-block
* Measure the crankshaft web to web width with a vernier cali-pers.
U Width between webs
Standard: 53.9-54.1 mm (2.122 - 2.130 in)
(Sj 09900-20101: Yernier calipers
♦ inspect each oil seal lip for wear and damagęv. \\ \
\ ^\\\\ > ■ K \ \ \ V
♦ Remove the oil seal with the special tool.
09913-50121: Oil seal remover