41. Carefully inspect torque corwerter for damage.
Check com/erter hub for grooves caused by hardened seals. Also check bushing contact area.
42. Lubricate oii pump lip seal and converter neck before installing converter.
43. Pour approx. 2-liters (2-1/8 US qt, 1-3/4 Imp qt) of automatic transmission fluid into converter housing.
SAT672
44. Install torque converter to converter housing.
Be careful not to scratch front cover oil seal.
45. Apply sealant to threads of drain pług and install it in place.
46. Install inhibitor switch to transaxle case.
47. Adjust inhibitor switch. Refer to On-vehicle Service.
48. Make surę that manuał lever operates smooth-ty.
SAT 406