Datę: Feb. 03, 2015
Page 2 of4
Test Result(s):
Test Sample Description:
Sample No. |
Sample Name |
Client Claimed Materiał |
Sample Description |
Location |
01 |
COVER |
PVC |
Black plastic |
Plastic part entirely |
1. Lead(Pb) content Test Method:
1) US EPA3050B: 1996 & US EPA6010C: 2007 Acid Digestion of Sediments, Sludges, and Soils
& lnductively Coupled Plasma-Atomic Emission Specfrometry
2) US EPA 3052: 1996 & US EPA 6010C: 2007
Microwave Assisted Arid Digestion of Siliceous and Organically Based Matrices & lnductively Coupled Plasma-Atomic Emission Spectrometry
3) ASTM E1645-01 (2007) & ASTM E 1613-12
Standard Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis
& Standard Test Method for Determination of Lead by lnductively Coupled Plasma Atomie Emission
Spectrometry (ICP-AES), Flame Atomie Absorption Spectrometry (FAAS), or Graphite Fumace Atomie Absorption Spectrometry (GFAAS) Technigues__
Sample No. |
Lead(Pb) |
Conclusion(s) | |||
Unit |
MDL |
Limit |
Result(s) | ||
01 |
mg/kg |
2 |
300 |
N.D. |
PASS |
Notę: 1. 1000mg/kg =0.1%;
2. MDL = Method Detection Umit;
3. N.D. = Not Detected (<MDL).
2. Cadmium(Cd) content Test Method:
1) US EPA3050B: 1996 & US EPA6010C: 2007 Acid Digestion of Sediments. Sludges. and Soils
& lnductively Coupled Plasma-Atomic Emission Spectrometry
2) US EPA 3052: 1996 & US EPA 6010C: 2007
Microwave Assisted Add Digestion of Siliceous and Organically Based Matrices
& lnductively Coupled Plasma-Atomic Emission Spectrometry
Sample No. |
Cadmium(Cd) |
Conclusion(s) | |||
Unit |
MDL |
Limit |
Result(s) | ||
01 |
mgftg |
2 |
300 |
N.D. |
PASS |
This report is onlyresponsible for the tested sample(s) from the dient Wtthout the wribng agreement of the company, the dient is not allowed to cepy the report In part (enbre copy is excepted)
BonteKNrgbo) Compiiance Testing Leboratory Co . Ltd 3/F.. No 555. Fuqiang Road. Yinzhou District. Ningbo. Zhejiang. China Website vmvi bctlab com Tet +86-574-89201291